Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of press fittings with a brass body and EPDM ‘O’-rings for use with copper pipe manufactured to EN1057:2006 +A1:2010 seamless round copper tube R250. Joints are achieved using a specialist press fitting tool. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Universal plastic compression adaptor kits for use with SAB A16 fitting body (not included as part of this approval) and galvanised steel pipe (manufactured to EN 10255). Maximum working pressure 16 bar. Cold water use only.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of dual flush, WC outlet valves with an ABS body. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of dual flush WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of height adjustable WC syphonic dual flush valves with polypropylene bodies and stainless-steel links. Cold water use only.
Range of dual flush syphonic WC flush valves. Cold water use only.
Range of dual flush syphonic WC flush valves. Cold water use only.
Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of solar assisted direct gas fired condensing storage water heaters with an enamel lining and a titanium anode incorporating a solar heat exchanger (max. working pressure 6,0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C
Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C
Range of integrated water circuits incorporating a plate heat exchanger. The units incorporate a flow sensor, pressure relief valve set at 3.0 bar, and a primary circuit circulation pump. Maximum working pressure secondary circuit 10.0 bar. Maximum working pressure primary circuit 2.5 bar. Maximum operating temperature 70°C. Cold supply only.
Range of ¼ turn ceramic disc (brass bodies), non rising spindles (brass bodies) or ceramic cartridge headworks (plastic bodies) insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of in-line and concentric water meters with composite bodies, TPE gasket and NBR ‘O’-ring(s). The products have an integral plastic filter. The inlet of the in-line models includes a non-return valve. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. The products have an integral plastic filter. The inlet includes a non-return valve. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Octave range of water meters with blue epoxy coated cast iron or plastic bodies (see models). Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C
‘Helvatron H2O’ range of ultrasonic water meters with brass bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of concealed, wall mounted rough insets, incorporating cross-top and single lever operating members. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower hose. Model (5840/MBG/W) is supplied with a single lever trim set. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Handset, incorporating chromium plated plastic body with a plastic aerator. Open outlet use only Maximum operating temperature 60.0°C
‘Monsoon Standard’ range of single and twin ended shower booster pumps with brass bodies, brass impellers, EPDM seals and NBR ‘O’-rings. The inlet(s) of the pump body incorporate(s) a plastic strainer. Models with push fit connections include an integral isolation valve. Pushfit connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of overhead shower outlets with chromium plated brass bodies. For installation with specific rough kit sets, incorporating stainless steel strainers and flow regulators in the inlet. Maximum operating temperature 80.0°C For open outlet use
Concealed, wall mounted elbow fitting with a brass body incorporating EDPM `O`-rings. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 70.0°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets with chrome plated brass bodies incorporating a single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 28450410 is a wall elbow for use with the shower sets and incorporates a check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature: 60.0°C
Range of shower outlets, (brass bodies - various finishes), incorporating ball joints, EPDM ‘O’-rings and NBR rubber seals. Maximum operating temperature 60°C
Range of wall or ceiling mounted shower outlets with plastic bodies (various finishes) and brass shower arms (various finishes, incorporating EPDM O-rings and plastic flow regulators. Maximum operating temperature 60°C.
Range of chrome plated plastic bodied or brass bodied (28 489 xxx model) overhead shower outlets. The 27 405 xxx model is supplied with a ceiling mounted shower arm and the 27 424 xxx models with a wall mounted shower arm, both are chromium plated brass. All shower outlets incorporate a combined EPDM washer and plastic strainer on the inlet. Maximum operating temperature 70°C.
Range of shower kits, comprising of (chrome plated or white) shower handsets that incorporate flow restrictors in the inlets, shower hoses and riser rail assemblies. The handsets can also be supplied separately (see models). Maximum operating temperature 65°C.
Range of shower kits, comprising of (chrome or matte black) shower handsets, shower hoses and riser rail assemblies. The shower handsets incorporate plastic flow regulators. Maximum operating temperature: 60°C.
Range of in-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE gaskets. Maximum working pressure 20 bar. Maximum operating temperature 85°C.
Range of electronic pressure switches housed in a plastic body with a ceramic sensor and NBR gaskets and/or ‘O’-rings. The U480015 and U480016 models incorporate a spring-loaded plastic flow restrictor. Maximum working pressure 12.0 bar. Cold water only.
Range of electronic pressure switches housed in a plastic body with a ceramic sensor and NBR gaskets and/or ‘O’-rings. The 1091203260 & G0912026 models incorporate a spring-loaded plastic flow restrictor. Maximum working pressure 12.0 bar. Cold water only.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome type operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of bath pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and cross top operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 10 Bar. Maximum operating temperature 60°C.
Basin pillar tap (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straighteners. The products are supplied with metal backnuts. Models (VAL2 ½ E4 C CD & VAL2 ½ E6 C CD) are supplied with optional aerators that incorporate flow regulators. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar, Maximum operating temperature 65°C.
Range of deck mounted, fixed or swivel (model 909101 only), self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operating members (see models). The outlets incorporate a plastic flow straightener or aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, fixed, self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operated operating members (see models). The outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Self-closing combination tap assembly (chromium plated brass) with a spring-loaded headwork controlling both temperature and flow with a dome type operating member. The spout outlet incorporates a plastic flow straightener. The flexible hose inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Adaptor assembly consisting of a brass fitting with EPDM washer and PEX hose. Open outlet use only Maximum operating temperature 60°C
Page 169 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.