Range of dual flushing WC outletvalves with plastic bodies and silicone gasket. Cold water use only.
Range of WC dual flush drop valves comprising of a plastic body, silicone seal and an internal overflow. The valve is operated via a push button or lever assembly for either full or reduced flush. Cold water use only.
Range of outdoor air to water heat exchanger units incorporating a pump, drain valve and isolation valve. Maximum working pressure 5.0 bar. Maximum operating temperature 90°C
‘E-WATER BLOCK’ self-closing valves with black plastic bodies and stainless-steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Copper corrugated hose. Maximum working pressure 10.0 bar. Maximum working temperature 90°C.
Range of plastic bodied quarter turn isolation valves, with EPDM rubber ‘O’-rings, seals and washers. The 52.009.100 model is operated by a hex key (not supplied), the 52.009.200 model is operated by a key (supplied). Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of water meter couplings with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only
Appliance inlet group assembly comprising of an EPDM gasket, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a flexible reinforced hose assembly with a PVC lining and a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 5.0 bar. Cold water use only.
Range of cast iron (blue epoxy coated) (G versions only) or stainless steel (all other versions - F, N, R, T) vertical multistage pumps with stainless steel impellers, shaft and outer sleeve and EPDM 'O'-rings and seals. The pumps incorporate a ceramic/carbon graphite/EPDM and stainless steel mechanical shaft seal (QBEGG). Maximum working pressures: 1-22SV models: 1SV27-1SV37 (F VERSION) - PN16 (25mm). 3SV23-3SV33 (F VERSION) - PN16 (25mm). 5SV23-5SV33 (F VERSION) - PN16 (32mm). 10SV27-10SV21 (F VERSION) - PN16 (40mm). 15SV11-15SV17 (F VERSION) - PN16 (50mm). 22SV12-22SV17 (F VERSION) - PN16 (50mm). 1SV02-1SV25 (F VERSION) - PN25 (25mm). 3SV02-3SV21 (F VERSION) - PN25 (25mm). 5SV02-5SV16 (F VERSION) - PN25 (32mm). 10SV01-10SV13 (F VERSION) - PN25 (40mm). 15SV01-15SV10 (F VERSION) - PN25 (50mm). 22SV01-22SV10 (F VERSION) - PN25 (50mm). N VERSIONS ALL MODELS - PN25 (25-50mm). R VERSION ALL MODELS - PN25 (25-50mm). T VERSION ALL MODELS - PN16 (25-50mm). 33-125SV models: 33SV1-33SV5, 33SV6/2AG150T/D & 33SV6/2AN150T/D (G or N VERSION) - PN16 (65mm). 46SV1-46SV5 (G or N VERSION) - PN16 (80mm). 66SV1-66SV5 (G or N VERSION) - PN16 (100mm). 92SV1-92SV4 (G or N VERSION) - PN16 (100mm). 125SV1-125SV6 (G VERSION) - PN16 (125mm). 33SV7-33SV10, 33SV6/1AG150T/D, 33SV6/1AN150T/D, 33SV6G150T/D & 33SV6N150T/D (G VERSION) - PN25, (N VERSION) - PN16 (65mm). 46SV6-46SV9 (G VERSION) - PN25, (N VERSION) - PN16 (80mm). 66SV6-66SV8 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 92SV5-92SV7 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 125SV7-125SV8 (G VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only. VERSION) - PN25 (100mm). 92SV5-92SV7 (G or N VERSION) - PN25 (100mm). 125SV7-125SV8 (G or N VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only.
Range of booster pumps with stainless steel bodies and impellers (AISI 304: AL-RED models or AISI 316: CP models), EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure: CP(m) 100-130-132-150-158 and AL-RED(m) 600-610-620 models: 6.0 bar. All other models: 8.0 bar. Maximum operating temperature 90°C.
Range of shower arms with a brass body and various finishes. Maximum operating temperature 60°C.
Range of wall mounted compact shower panels with push button timed flow control. The inlet incorporates a plastic flow regulator and a stainless-steel strainer. Maximum working pressure 4.0 Bar Maximum operating temperature 60°C
Concealed installation set for use with wall mounted overhead shower outlets (brass body – various finishes). The inlet to the shower outlet incorporates a stainless-steel strainer, a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass or stainless-steel bodies (various finishes). Maximum operating temperature 65°C.
Range of shower handsets and hoses with either a brass or stainless-steel body (various finishes). Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The spout outlets incorporate a plastic aerator (AX-IRO-106-CP, AX-MET-106-CP & AX-MET-1369-CP models only) or a plastic flow straightener (AX-IRO-136-CP model only). The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating pressure 60°C.
Self-closing tap for drinking water fountains (chromium plated brass) with dome type operating member. The spout outlet incorporates a stainless-steel strainer. The product is supplied with a metal back nut. Maximum working pressure 5.0 bar. Cold water use only.
Range of self-closing taps (chromium plated brass) incorporating spring loaded headworks with dome type operating members. The spout outlet of the 9000 model incorporates a plastic flow straightener. The products are supplied with a metal back nut. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C, except for the 9054SA model which is cold water use only.
Self-closing drinking fountain tap (chromium plated brass) with non-concussive headwork operated via a push button. The tap incorporates a metal shroud and is supplied with a metal back nut. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower hoses incorporating stainless steel interlocking outer with PVC inner liner or PVC outer and PVC inner liner (see model). Maximum operating temperature 65°C.
McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Stainless steel indirect thermal store. The primary circuit is factory fitted with a temperature and pressure relief valve (3 bar and 92°C). Hot water storage for space heating via air to water heat pump Maximum working pressure: Primary circuit 3.0 bar Maximum operating temperature 85°C.
SSB, SSI SST range of stainless steel unvented cylinders provided with an unvented kit supplied with cylinders containing a temperature and pressure reducing valve set at 3.0 bar and an expansion vessel and single check valve (suitable for fluid category 2) . Available as storage tank, indirect or twin coil. Maximum working pressure of the cylinder 6.0 bar, maximum working pressure of the coil or coils 12.0 bar. Maximum operating temperature 95°C.
Range of domestic stainless steel indirect unvented hot water storage cylinder incorporating a stainless steel coil for connection to a heat pump circuit. The secondary circuit is factory fitted with a temperature and pressure relief valve (10 bar and 92°C) and an Incoloy immersion heater and magnesium sacrificial anode. Maximum working pressure: Secondary circuit 9.5 bar. Maximum operating temperature 95°C.
Range of wall mounted thermostatic shower valves, riser rail, shower handset, shower hose and overhead shower outlet. The valve incorporates a brass body (various finishes) and ceramic disc headwork with dome type operating member which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Inlets incorporate stainless steel filters and a single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The DC3002 & DC3007 prefix models incorporate a 2-way ceramic disc diverter headwork with dome (DC3001 models) or cubed type (DC3006 & DC3007 models) operating members controlling the flow either shower outlet. The DC3001 model incorporate a ¼ turn ceramic disc headwork with dome (DC3001 & DC3002 models) or cubed type (DC3006 & DC3007 models) operating members controlling the flow to a single shower outlet. The temperature is controlled independently via a thermostatic cartridge. The inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 80°C.
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and trim sets (various finishes). The temperature is controlled via a thermostatic cartridge with a cross top or single lever operating member. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic mixing vales with brass bodies and chrome plated trim sets, incorporating one or two quarter turn ceramic disc headworks with various operating members (see models). Temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork (with various operating members). The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.
Range of water filters cartridges with plastic bodies and either carbon block or activated carbon filter media. Maximum working pressure 8.6 bar. Maximum operating temperature 38°C.
Wall mounted exposed thermostatic shower valve incorporating a brass body (various finishes), quarter turn ceramic disc headwork with single lever operating members and manual diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with cross top type operating member. The inlets incorporate a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). The product is supplied with an overhead shower, shower handset, riser rail and shower hose. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves incorporating brass bodies (chrome plated) and a quarter turn ceramic disc headwork controlling the flow with single lever, cross top or dome type operating members. The temperature controlled is independently via a thermostatic cartridge incorporating a manual override button with cross top, dome type or single lever operating members. Both inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete assemblies have not been fully tested to demonstrate that they provide adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic shower blending valves incorporating stainless steel bodies, a 2-way ceramic disc headwork and a single lever operating member controlling the flow. The temperature is controlled independently via a thermostatic cartridge with a single lever incorporating a manual override operating member. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wafer type butterfly valves incorporating blue epoxy coated cast iron bodies and stainless steel discs. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of wafer and lugged type, concentric butterfly valves with epoxy coated cast iron bodies, austenitic steel discs and EPDM seats. Maximum working pressure 16.0 bar. Cold water use only.
Ceramic disc diverter cartridge incorporating a plastic body for use in specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of wall mounted, concealed, rough in sets with brass bodies. The product is supplied with a separate trim set incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed flow control valves with brass bodies, incorporating either one or two quarter turn ceramic disc headworks with single lever operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
‘Europress’ range of in-line pressure reducing valves, with DZR brass bodies and EPDM ‘O’-rings and washer. The outlet pressure is adjustable between 1.0 - 5.5 bar. Operating parameters: 2430012 EUROPRESS model: Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C. 2430034 EUROPRESS & 2430100 EUROPRESS models: Maximum inlet supply pressure 16.0 bar. Maximum operating temperature 99°C.
Range of pressure relief valves pre-set @ 6.0 bar, incorporating DZR brass bodies, EPDM seal cup and EPDM ‘O’-ring. Maximum operating temperature 99˚C
‘EV220A-W’ range of normally closed solenoid valves with brass bodies, EPDM diaphragms and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Quarter turn sanitry ball valve incorporating a brass body and ball, EPDM ‘O’-ring and PTFE seat. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of angled isolation valves with brass bodies (brushed chrome plated), for use with copper tube manufactured to EN1057. The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of gate valves with brass bodies, brass wedges and PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. To be used with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.
Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.
Range of water conditioners incorporating a static PTFE and zinc anode in a brass or nickel plated bronze body. Between November 2021 and December 2023 the maximum working pressure is: ET/ETD models = 10.0bar, EF/EF-16 models = 16.0 bar, EF-40 models = 40.0 bar. From January 2024 the maximum working pressure is: ET/ETD/EF/EF-16 models = 16.0 bar & EF-40 models = 40.0 bar. Maximum operating temperature 60°C.
Range of UV disinfection units with stainless steel and EPDM seals. The UV lamps are housed inside synthetic quartz tubes Maximum working pressure 6.9 bar. Cold water use only.
'TEPCON® M90 NAT CF2001 & TEPCON® M270 NAT CF2001'. Natural (appears white in colour), injection moulded acetal materials. For use with hot and cold water up to 85°C.
Hostaform®, injection moulded POM materials. For use with water up to 85°C: Hostaform® Special Grade: M25AE 10-2013 & M25AE 10-2013 ECO-B (black coloured). Hostaform® Glass Bead Filled Grade: C9021 GV3/30 NATURAL. Hostaform® M30RS Natural & M30RS ECO-B NATURAL. For use with water up to 65°C: Hostaform® Unfilled Grades: T1020 NATURAL. Hostaform® Glass Fibre Filled Grades: C9021 GV1/10 NATURAL, C9021 GV1/20 NATURAL, C9021 GV1/30 NATURAL, C9021 GV1/30 3134 NATURAL & C9021 GV1/30 3134 ECO-B NATURAL. Hostaform® Glass Bead Filled Grades: C9021 GV3/10 NATURAL & C9021 GV3/20 NATURAL. Hostaform® Special Grades: M25IE natural, M25IE ECO-B NATURAL & M30AE. Between April 2021 and 2nd August 2022, these grades were for use with water up to 65°C. Between 3rd August 2022 and 30th April 2026, these grades are for use with water up to 85°C: Hostaform® Unfilled Grades: M15HP NATURAL, M15HP ECO-B NATURAL, C2521 NATURAL, C2521 ECO-B NATURAL, C9021, C9021 ECO-B NATURAL, C 9021 ECO-C 872 NATURAL, C13021 NATURAL, C13021 ECO-B NATURAL, C 13021 ECO-C 872 NATURAL, C13031 NATURAL, C13031 ECO-B NATURAL, C 13031 ECO-C 872 NATURAL, C27021 NATURAL, C27021 ECO-B NATURAL & C 27021 ECO-C 872 NATURAL. Hostaform® Lubricated Grades: C9021 M (Natural colour is grey), C9021 M ECO-B NATURAL, C9021 FCT1 NATURAL, C9021 FCT1 ECO-B NATURAL, C9021 TF NATURAL, C9021 TF ECO-B NATURAL, C9021 K NATURAL, C9021 K ECO-B NATURAL, C13021RM NATURAL & C13021RM ECO-B NATURAL. Hostaform® Special Grade: MR130ACS NATURAL & MR130ACS ECO-B NATURAL. These grades were added January 2022. Between January 2022 and 2nd August 2022, these grades were for use with water up to 65°C. Between 3rd August 2022 and 30th April 2026, these grades are for use with water up to 85°C: Tarnoform® 200 CE natural, 300 CE natural, 400 CE natural, 411 CE natural & 500 CE natural. Between April 2021 and xx February 2023, these grades were for use with water up to 65°C. Between 16th February 2023 and 30th April 2026, these grades are for use with water up to 85°C: Hostaform® Unfilled Grades: C 52021 NATURAL & C 52021 ECO-B NATURAL. Tarnoform® 700 CE. Hostaform® Special Grades: C13031 XAS-G NATURAL, C13031 XAS-G ECO-B NATURAL, M25AE NATURAL, M25AE ECO-B NATURAL & HF M25AE ECO-C 872 NATURAL. For use with water up to 65°C: Grade added February 2023: Hostaform® M25AE 10/5358 DW. Grade added April 2025: Hostaform® MR130 ACS 10/5358 DW Black. For use with water up to 85°C: Grade added April 2025: Hostaform® M25AE 10/5358 DW black.
Page 11 of 85
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.