‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass caplillary fittings for use with EN1057 copper tube. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings for use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
End Feed Range copper fittings for use with copper tube. For above and below ground use Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.
Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of pump docking manifolds with plastic bodies and NBR, EPDM and FKM ‘O’-rings. Maximum working pressure 8.0 bar. Cold water use only.
Stainless steel bodied sensor with EPDM ‘O’-ring. Maximum operating temperature 90°C.
“Yonos PARA Z15 and Yonos PARA Z25 ” range of circulation pumps incorporating brass bodies, plastic impellers and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of vertical submersible multistage pumps. Cold water use only. Open outlet use only.
Range of central heating pumps incorporating polyether sulphone impellers, copper-tin alloy body, carbon graphite axial bearings and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
CM(E)(C) range of electronically operated pumps available in stainless steel, (‘EN 1.4301/AISI304’ or ‘EN 1.4401 /AISI316’) and cast iron. (CMEC models were added October 2023). The pumps are supplied with Sic-Sic mechanical shaft seals and FKM or EPDM seals. Cast iron models: Maximum working pressure 10.0 bar. Cold water use only. Stainless steel models: Maximum working pressure 16.0 bar. Maximum operating temperature 60°C for self-priming models, 99°C for all other models.
Range of submersible pumps with stainless steel bodies, impellers and shaft. The XPW range incorporates a strainer cowl on the suction end of the pump. The XPWA range features a stainless head which provides a threaded connection instead of the strainer. Cold water use only.
Overhead, ceiling mounted shower outlet with chromium plated brass body (various finishes). Maximum operating temperature 60°C.
Range of over head shower outlets incorporating brass bodies and an adjustable ball joint. The inlet incorporates a combined NBR washer and stainless-steel filter. Maximum operating temperature 60°C.
Range of shower outlets with brass bodies (various finishes) and NBR ‘O’ rings. The inlets incorporate a flow regulator. Maximum operating temperature 60°C. Open outlet use only.
Range of shower handsets with a chromium plated plastic body. The inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes), with a ball joint, EPDM ‘O’-rings and a NBR seal. The inlet incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets, various finishes. All models incorporate a stainless-steel strainer in the inlet. The inlet of model 26 090 also incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets and shower heads chrome plated plastic bodies and built in combined flow restrictors/approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models added March 2023 are available in various finishes, see model.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets and shower heads with chromium plated ABS bodies (models A111101 & A121510WT is not chromium plated). Maximum operating temperature 75°C.
Range of in-line `Y`-patterned strainers with either brass or DZR brass bodies (see model) incorporating a stainless steel mesh strainer and a PTFE washer. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
In-line `Y`-patterned strainers with bronze bodies incorporating stainless steel mesh strainers and PTFE washers. Maximum working pressure 20.0 bar. Maximum operating temperature 85.0°C
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Drain off valve with brass body (chrome plated) and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted taps (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall or floor mounted, self-closing taps (chromium plated brass) with spring loaded headworks and either dome type, foot pedal or stick operating members. The outlet of model 9003S incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Range of self-closing basin taps (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlets incorporate a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
‘TAQ PEX’ range of PEX lined flexible hose assemblies with either stainless steel braiding or grey polymeric (PET - Polyethylene terephthalate) braiding (ACB suffix models). Models have either EPDM ‘O’-rings and/or EPDM or silicone washers (depending on end connection). Models are also available with an optional washer incorporating a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided PE-X lined flexible hose assemblies incorporating NBR washers and various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of automatic air venting valves with a brass body and a plastic float. Maximum working pressure 10.0 bar. Maximum operating temperature 115°C.
Range of concealed flow controls (brass body with various different finishes) incorporating two, quarter turn ceramic disc headworks with single lever operating members controlling the flow to an external outlet (not supplied). Model BK2 is a flow control with adjustable bracket and collection box. Model BK2A is a flow control with bracket. Model BK2B is a flow control. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of manually operated, wall mounted, concealed blending valves (chromium plated brass), incorporating a ceramic cartridge headwork, controlling both flow and temperature, with a single lever operating member. All models incorporate integrated shower connections and hoses. Model 36111970 is supplied with a mounting bracket. The inlets of all models incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Shower kit consisting of a wall mounted thermostatic blending valve with a brass body (chrome plated), incorporating a single sequential headwork controlling both temperature and flow using a single lever operating member. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail & soap tray. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Shower kit consisting of a wall mounted (concealed or exposed) thermostatic blending valve with a brass body (chrome plated). Flow is controlled by a quarter turn ceramic disc headwork with single lever operating member, temperature is controlled by a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset & riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Shower kit consisting of a wall mounted thermostatic blending valve with a brass body (chrome plated), incorporating quarter turn ceramic disc headwork which controls the flow with dome operating members, temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporate a manual override button.. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower hose, shower handset, riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 2 of 85
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.