Single check valve assembly with a brushed nickel coated DZR brass body, incorporating a screwdriver operated isolation valve and EPDM ‘O’ rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass or chrome plated DZR brass (CP02-8511 suffix models) body with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass body with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies with DZR brass bodies, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Non-verifiable double check valve assembly incorporating DZR brass (chrome plated) body two spring loaded, resilient trim in-line check valve cartridges & a drain port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of non verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. The products incorporate a drain port between the cartridges. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies, consisting of two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies (brushed chrome plated) with a drain port located between the cartridges either at the top or bottom. Models incorporate an isolation valve with either lever or butterfly handles. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body, compression models are nickle plated. A drain port is provided between the cartridges. Compression models are to be used with copper pipe to EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature for the D220W range 85°C. Maximum operating temperature of the D200CW range 60°C.
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body, compression models are nickle plated. A drain port is provided between the cartridges. Compression models are to be used with copper pipe to EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature for the Hattersley Fig 250W range 85°C. Maximum operating temperature of the Hattersley Fig 250CW is 60°C
Tundish with a black metal body and a straight through pattern. The tundish complies with the requirements of an air gap to drain. Maximum operating temperature 99°C.
Tundish which incorporates a black or white plastic body and complies with the requirements of air gap to drain. Incorporates a spring loaded diaphragm on the outlet. Maximum operating temperature 100°C.
Range of tundishes with plastic body which comply with the requirements of an air break to drain. The outlet incorporates a spring loaded diaphragm Maximum operating temperature 85°C.
Commercial pasta cooker. Flow is controlled by a solenoid valve and discharges via a stainless-steel spout outlet Maximum working pressure 3.0 bar. Cold water supply only.
Range of open or closed top, circular, sectional, cold water storage cisterns with corrugated & galvanised steel bodies and an EPDM liner.
Range of three hole, deck mounted, single outlet (fixed) combination bidet tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The spout outlet incorporates a plastic aerator. Product is supplied with pop up waste & metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a pull out spray with push button trigger assembly and dome type operating member. The pull out spray also incorporates a single check valve assembly (however the complete unit has not been tested to demonstrate it provides adequate backflow protection). The outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assembly with a brass body (various finished and styles), incorporating a quarter turn ceramic disc headwork with cross top operating members. The spout outlet incorporates a plastic aerator and the product is supplied with a pop-up waste. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Deck mounted drinking fountain tap having a stainless steel body with an integeral shroud over the outlet. Outlet incorporates a stainless steel cover and strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate either a plastic flow straightener or aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with (chromium plated) brass bodies, incorporating quarter turn ceramic disc headworks or ceramic cartridge headworks (see models) with single lever operating members. The swivel spout of the TMO35SSCM model is (chromium plated) stainless steel. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (fixed) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied). The spout outlet of ‘Arc’ models incorporates a plastic flow straightener. All models incorporate a separate vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature 100°C. Hot-water circuit has a maximum operating temperature of 65°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with metal backnuts and the spout outlets incorporate a plastic aerator or a plastic flow straightener (supplied with both). Maximum working pressure 5.0 Bar Maximum operating temperature 60°C.
Two hole, single outlet (fixed), combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A range of combined bath filler and overflow with a plastic body (various trim sets). The outlet incorporates a plastic flow regulator and the products are supplied with a click waste. Maximum operating temperature 65°C.
Ranges of combined bath filler and overflow waste assembly incorporating a cable operated pop-up waste. Maximum operating temperature 65°C.
‘HydroDOS’ chlorine dioxide dosing system with PVC-u pipework and EPDM ‘O’-rings. The product incorporates a water meter, strainer, isolation valves and a drain cock with hose spigot. Maximum working pressure 6.0 bar. Cold water use only.
Range of cylindrical expansion vessels incorporating butyl rubber diaphragms. The products are supplied with an Airfix TD T piece. Maximum working pressure of model Airfix D 35 litre is 8.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Talbot range of self tapping ferrule straps with plastic bodies and a nitrile rubber seal. The product incorporates either a ¾” BSP (M) connection or a 25mm or 32mm push fit connection on the outlet from the cutting arm. For below ground use only. Maximum working pressure 16.0 bar. Cold water use only.
Range of LK press fittings with brass bodies and stainless steel sleeves for use with LK Universal PEX pipe. Jointing is achieved by hydraulic compression. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of Aquaterra PP-RCT socket fusion fittings for use with Aquaterra PP-RCT SDR 6 pipe and Aquaterra PP-RCT SDR 7.4 pipe (manufactured to EN ISO 15874). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
‘Epsilon Series’ polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Aquaflow polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of WC dual flush drop valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
Dual flush WC drop valve with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only
Dual flush WC drop valve with an internal overflow. The valve is operated via a lever operated assembly for either full or reduced flush. Cold water use only.
Range of WC dual flush outlet valves with silicon seals and ABS bodies. The SKY005, SKY015 & SKY020 valves are operated via a push button assembly for either full or reduced flush. The SKY030 model may be operated via a push button assembly or a lever for either full or reduced flush. The valves incorporate an internal overflow. For cold water use only.
WC dual flush drop valve with plastic body silicone and rubber seal. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold Water Use Only.
WC dual flush drop valve comprising of a plastic body and silicone seating washer. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water only.
Range of commercial glass washing machines with flow controlled via a solenoid valve. The products are supplied with a dual layer supply hose (Grey PVC outer/Black PVC inner) with ¾” captive nuts at either end and a loose double check valve assembly (suitable for backflow protection against Fluid Category 3) for installation prior to the inlet hose. Maximum working pressure 4.0 Bar. Cold water use only.
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of ‘HYCO’ electric instantaneous water heaters with plastic bodies, NBR and silicone ‘O’-rings. The inlet of model IN96T incorporates a plastic strainer. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.
‘Hydraulic Block 2’ range of integrated water circuits for use with combination boilers comprising of a plastic body, stainless steel thermistors and a plate heat exchanger. The primary circuit incorporates a pump assembly. Maximum working pressures: Primary Circuit 2.5 bar. Secondary Circuit 10.0 bar. Maximum operating temperatures: Primary circuit 85˚C. Secondary circuit 65°C. Cold supply only.
Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C
Digital water meter with brass body incorporating a plastic strainer on the inlet and a non-return valve (not suitable for backflow protection) on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Page 1 of 19
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.