Range of two hole,wall mounted, concealed, tap assemblies, including spout outlet, trim set and single lever operating members (various finishes). The spout outlet incorporates a plastic flow straightener and a plastic flow regulator on the inlet. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headworks with various types of operating members and plastic aerators. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Wall mounted bath shower mixer with brass body (various finishes). Ceramic disc headwork with dome operating members, manually operated diverter to shower outlets. The temperature is controlled independently via a thermostatic cartridge using a single lever operating member. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Spout outlet incorporates a plastic aerator. Products are supplied with shower headhead, shower handset and shower hose. Maximum operating pressure 10 Bar. Maximum operating temperature 85°C.
Range of wall mounted two-hole, single outlet, (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with dome or cube type operating members and a manual diverter located on the spout to a shower handset or spout Temperature is controlled by a thermostatic cartridge with a dome or cubed type operating member with an override button. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) with a self-cancelling diverter to a shower outlet. The product incorporates a ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts, stainless steel braided PVC lined shower hose and chromium plated shower handset. Maximum operating pressure 5 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
A range of wall mounted two-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes see models), incorporating quarter turn ceramic disc headworks, dome type operating members and self-cancelling diverter to shower outlets. The temperature is controlled independently via thermostatic cartridges with dome type operating members. Both operating members incorporate a manual override. Spout outlet incorporates a plastic aerator. Products are supplied with shower hose, shower handset and overhead shower. The inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener and the products are supplied with metal backnuts, a shower handset and hose assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a lockable self-cancelling diverter to shower outlet. The flow is controlled by a quarter turn ceramic disc headwork with a dome operating member and the temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of two-hole, double outlet, fixed combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with metal back nuts. Maximum operating pressure 6 bar. Maximum operating temperature 85°C
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. Connection between the side headwork and the spout tee piece is via stainless steel braided PEX lined flexible hose assemblies. The copper inlet pipe to the spout incorporates a plastic flow regulator. The spout outlets incorporate a plastic flow straightener and the products are supplied with a lever type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of combined bath fillers, waste and overflow assemblies with a brass body (various finishes) incorporating a brass (706356/57/58 models) or plastic (1001347AQ** model) aerator and a click type waste. Maximum operating temperature 65°C.
Spout outlet consisting of a chromium plated brass body, plastic aerator and EPDM ‘O’ rings. Maximum operating temperature 60°C.
Range of welded stainless steel (S30408 or S31603) pipes. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
‘Blutron’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
“D” Range of stainless steel (304S31/316S11) press fittings for use with ‘DPX’ series 1 & 2 stainless steel (304S31/316S11) pipe. The fittings and tube are assembled using a crimping tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of JG Twist & Lock Speedfit push-fit fittings for use with JG Speedfit Layflat Polybutylene Barrier Pipe (BPB Pipe to BS EN 7291-2:2010), 'BPEX' Barrier Pipe.(BPEX Pipe to BS EN 7291-3:2010) and Copper Pipe to BS EN1057:2006 Max working pressure & operating temperature: 12.5 Bar at 20°C 6.0 Bar at 83°C
Range of brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of Conex >B< press fittings incorporating copper & brass bodies for use with copper tube (manufactured to EN1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
‘Trustlene’ range of electrofusion and spigot fittings, with PE100 or brass bodies, for use with SDR11 PE100 pipe (manufactured to IS 4984: 2016). For use above and below ground. Maximum working pressure 16.0 bar. Cold water use only.
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
SATK Series 22 range of wall-mounted direct heat interface units providing heating and instantaneous hot water. The hot water is generated via a plate heat exchanger. Maximum working pressure of all water circuits (secondary hot water, primary and space heating) 10.0 bar. Maximum operating temperature 90°C.
‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.
Non-metallic materials and components comply with BS6920 at 85°C
DZR brass elbow fitting. Compression connection to be used with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘JS’ range of water meters with brass bodies and EPDM ‘O’-rings and plastic strainer on inlet. Maximum working pressure 16 bar. Cold water use only.
Range of ultrasonic water meters with brass bodies and EPDM O-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of water meters with brass bodies. The inlets incorporate a plastic filter. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 50°C
Magnetic non-return valve with a brass body and EPDM seals. Maximum working pressure 16.0 Bar. Cold water use only.
Range of hose assemblies. Models B0301-148036-000 & B0301-148038-000 comprise of a spherical valve, stainless-steel braided EPDM lined flexible hose and double check valve assembly (suitable for backflow protection against fluid category 3). Model B0301-148037-000 comprises of a double check valve assembly (suitable for backflow protection against fluid category 3), stainless-steel braided EPDM lined flexible hose and ‘T’ type spherical valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of circulating pumps with a bronze body, plastic impeller and EPDM gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower outlets with plastic bodies (chromium finish). Incorporates flow a regulator. Claims of flow rate made by the manufacture on flow rate are not part of this approval. Maximum operating temperature 85°C
Range of shower outlets having plastic bodies, various finishes Maximum operating temperature 55°C
Range of shower outlet with plastic bodies (chromium plated) and plastic flow regulators. Model 27.369 supplied with a PVC multi-layered shower hose with EPDM washer and plastic strainer on inlet. Maximum working temperature 60°C.
Wall mounted shower heads and arms with chromium plated brass bodies. Maximum working temperature 60°C
Range of ceiling mounted, shower outlets with chrome plated brass bodies, EPDM seals, stainless steel strainer and flow regulator in the inlets. Supplied with a flexible hose. Maximum working temperature 60°C
Wall mounted shower heads and arms with chromium plated brass bodies. Supplied with plastic strainer. Maximum working temperature 65°C.
‘Grohe Euphoria 180’ overhead shower outlet with a chromium plated brass body incorporating a plastic flow regulator. Maximum working temperature 60°C.
Range of wall mounted shower outlets (various finishes). The inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C. Open outlet use only.
Range of overhead showers consisting of stainless steel bodies and silicone nozzles and gaskets and shower handsets consisting of brass bodies.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets with (plastic bodies - various finishes). The inlets incorporate a plastic flow restrictor. Maximum operating temperature 60.0°C Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets with brass bodies (various finishes). The products incorporate a stainless-steel strainer and flow regulator. Open outlet use.
Range of in-line `Y`-patterned strainers with brass bodies incorporating stainless steel mesh strainers and PTFE gaskets. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of in-line Y-pattern strainers with blue epoxy coated ductile iron bodies, EPDM ‘O’-rings and a stainless-steel mesh. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of ‘Y’ Strainers with blue epoxy coated ductile iron bodies, incorporating a stainless-steel mesh. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 85°C
Range of flow sensors with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of pillar taps with brass bodies, (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model). The spout outlet of the F5117** model incorporates a plastic aerator. The spout outlet of the F5197**, F6007**, F6008** & F6117C** models incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps with brass bodies, (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model). The spout outlet of the F5198** & F6118C** models incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate plastic aerators (except 2.1977.005 that has flow restrictor) and the products are supplied with plastic backnuts. Maximum operating pressure 5 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of stainless steel interlocked shower hose with PVC/silicon/PEX inner hoses and various end connections. Maximum operating temperature 65°C.
Range of nylon braided hoses with TPSiV inner liner and brass end connections incorporating EPDM washers.Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Page 71 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.