Range of deck mounted spout outlets (brass bodies - various finishes). Supplied with metal backnuts. Open outlet use only Maximum operating temperature: 60°C
Range of cylindrical or tubular expansion vessels with epoxy coated carbon steel bodies. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C
Range of AIS tin-plated brass and PPSU press fit fittings for use with MULTIPIPE multi layered PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of MULTITUBO tin-plated brass and PPSU press fit fittings for use with MULTITUBO multi layered PE-RT/AL/PE-RT pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of ‘NiroSan’ stainless-steel crimped fittings incorporating EPDM ‘O’ Rings, for use with ‘NiroSan’, ‘NiroSan SF’ & ‘NiroSan -ECO’ stainless-steel pipe (all manufactured to EN10312). The fittings and pipe are assembled using a crimping tool with either ‘M’ (15-108mm), ‘V’ (15-54mm) or ‘SA’ (15-108mm) crimping profiles. For above ground use only. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
‘BORPLUS’ range of PP-RCT Socket Fusion fittings used with ‘BORPLUS PP-RCT FASER COMPOSITE STABIL’ pipe. Maximum working pressures at 16.0 Bar @ 23°C and 6.0 Bar @ 85°C.
‘Hansen easy fit’ range of polypropylene compression fittings with EPDM ‘O’-rings for use with metric PE80 (20mm-63mm) and PE100 (32mm-110mm) pipe to AS/NZS:4130 and plastic pipe inserts. For above and below ground use. Maximum working pressure: See models. Maximum operating temperature: Cold water use only.
Range of M profile brass press fittings with EPDM ‘O’-rings or gaskets to be used with copper pipe manufactured to EN1057 for above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘Isiflo Sprint’ push fit fittings for use with PE100 pipe (manufactured in accordance with EN 12201), for above and below ground use. Isiflo Sprint Family fittings can be installed with seal liners, support liners and without any liner. Maximum working pressure 16 bar. Cold water use only.
SANHA Press Series 6000 & 16000 and PURAPRESS Series 8000 of press-fit fittings with copper (6000), bronze (8000) and chrome plated copper (16000) bodies and EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Dual flush, WC outlet valves. Model A2706 is operated via a push button assembly for either full or reduced flush. Maximum operating temperature. Cold water use only.
Domestic hot water heat recovery unit incorporating a stainless steel plate heat exchanger. The product is supplied with 15mm x 15mm compression 90° elbows for installation on the inlet and outlet. Maximum operating pressure 10 bar. Maximum operating temperature 80°C
Range of electric instantaneous heated showers, incorporating a solenoid valve to control the flow. Products are supplied with a shower hose and handset. Maximum supply pressure 10 bar. Maximum operating temperature 45°C.
Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of solar assisted direct gas fired condensing storage water heaters with an enamel lining and a titanium anode incorporating a solar heat exchanger (max. working pressure 6,0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C
Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C
Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of solar assisted direct gas fired condensing storage water heaters with an enamel lining and a titanium anode incorporating a solar heat exchanger (max. working pressure 6,0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Arrangement of PVC-U pipe and fittings for use with the Orca System. Maximum working pressure 9.0 bar. Cold water use only.
‘Monsoon Standard’ range of single and twin ended shower booster pumps with brass bodies, brass impellers, EPDM seals and NBR ‘O’-rings. The inlet(s) of the pump body incorporate(s) a plastic strainer. Models with push fit connections include an integral isolation valve. Pushfit connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.
Range of multistage pumps with stainless steel bodies, impellers, shaft and outer sleeve. SC family models are submersible pumps. SCD family models are surface pumps only. SCDS family models can be used either as a surface pump or as a submersible pump. SCD/SCDS models: Maximum working pressure 10.0 bar. SC models: Open outlet use only. Cold water use only.
Range of single or twin booster pumps with stainless steel bodies and stainless-steel impellers. Maximum working pressure 8.0 Bar Maximum operating temperature 90.0°C
Range of chrome plated plastic bodied or brass bodied (28 489 xxx model) overhead shower outlets. The 27 405 xxx model is supplied with a ceiling mounted shower arm and the 27 424 xxx models with a wall mounted shower arm, both are chromium plated brass. All shower outlets incorporate a combined EPDM washer and plastic strainer on the inlet. Maximum operating temperature 70°C.
Range of shower kits, comprising of (chrome or matte black) shower handsets, shower hoses and riser rail assemblies. The shower handsets incorporate plastic flow regulators. Maximum operating temperature: 60°C.
Range of showers handsets with plastic bodies. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower heads with plastic bodies. with stainless-steel strainer plastic flow regulator on the inlet.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted shower outlets (chromium plated brass bodies). The inlets incorporate check valve cartridges, however, the complete assemblies have not been tested to demonstrate they provide backflow protection. The inlets also include built-in flow regulators. Maximum operating temperature 60.0°C. For open outlet use only.
A range of plastic overhead shower heads and shower handsets with various finishes. Maximum operating temperature 65.0°C Open outlet use only
Wall outlet with a stainless steel body incorporating a shower handset holder. Maximum operating temperature 65°C.
Range of wall mounted shower arms with brass bodies (various finishes - see models). Maximum working temperature 70°C.
Range of electronic pressure switches housed in a plastic body with a ceramic sensor and NBR gaskets and/or ‘O’-rings. The 1091203260 & G0912026 models incorporate a spring-loaded plastic flow restrictor. Maximum working pressure 12.0 bar. Cold water only.
Range of drain taps with brass body and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). Maximum working pressure 10 Bar. Maximum operating temperature 85°C
Range of stainless-steel or nylon braided PEX lined hoses, incorporating EPDM O-ring or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided TPSiV lined flexible hose assemblies incorporating EPDM O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of Indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 90˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check cartridge, verified by test (suitable for backflow protection against fluid category 2) an expansion vessel and tundish. Maximum working pressure: Secondary: 4.0 Bar Primary: 3.0 Maximum operating temperature 99.0°C
Range of wall mounted, concealed, manual blending shower valves with brass bodies (various finishes), incorporating a ceramic cartridge headwork and various single lever operating members. The product is also supplied with ¾” BSP (M) x ½” BSP (F) adaptors. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Wall mounted, exposed, thermostatic bar type shower mixing valve (brass body, various finishes - see model). The product incorporates a 2-way ceramic disc diverter headwork with a single lever operating member controlling the flow to either shower outlet. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member and a manual override button. The product is supplied with a shower riser, overhead shower, shower hose and shower handset. The inlets incorporate a combined washer and stainless-steel strainer, as well as an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves, (brass bodies – chrome plated plastic trim sets) incorporating single sequential headworks controlling both flow and temperature. The inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate back flow protection. Model (31997W is valve only) all other models are supplied with shower hose, handset & riser rail assembly. Maximum operating pressure 5 bar. Maximum operating temperature 50°C
ange of wall mounted thermostatic shower valves, (brass bodies – chrome plated plastic trim sets). Incorporating a sequential headwork controlling flow and temperature. Model (31983W-CP) direction of flow is controlled independently with a single lever operating member that diverters from shower to shower. Model (31982W-CP) is supplied with a shower hose, handset & riser rail assembly. Model (31983W-CP) is supplied with a shower hose, handset, over head shower & riser rail assembly. Maximum operating pressure 5 bar. Maximum operating temperature 50°C
Page 63 of 81
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.