Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a single sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Product is supplied with a T-Type thermostatic mixing valve. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet hose Incorporates approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), Models M33136 & M1006 incorporate a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn rising spindle headworks with single lever operating members. The S8215AA model is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of wall mounted (swivel) spout outlets with chromium plated brass bodies, EDPM ‘O’-rings and a plastic flow straightener. DJ suffix models have a double swivel arm. Maximum operating temperature 65°C.
‘Quattroselect’ range of chemical dosing units incorporating a lockable self-closing trigger assembly and a self-closing bottle filler assembly which control the flow. The products are supplied with an approved double check valve assembly at the inlet (suitable for backflow prevention against fluid category 3). Maximum working pressure 5.8 bar. Cold water use only.
Range on inline filter cartridges incorporating plastic bodies. The filter media varies between models and includes active carbon, silver impregnated active carbon, silver carbon block & weak/strong cationic resin. Maximum working pressure 6.0 bar. Cold water use only.
Aquaflow polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of brass compression fittings for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of Irish compression fittings with brass bodies, nut and olives for use with Irish copper pipe manufactured to EN1057:2006+A1:2010. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Range of eccentric hemisphere valves incorporating blue epoxy coated carbon steel bodies and discs, EPDM seat and a handwheel operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Wall mounted outlet with detachable shower hose connector (42037UK model) and wall mounted shower outlet (42018UK model). The 42018UK model is supplied with an optional, detachable shower hose connector assembly which incorporates an integral plastic flow regulator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 42037UK has a maximum operating temperature of 80°C. Model 42018UK has a maximum operating temperature of 60°C.
Wall bracket with a brass body (chrome plated) and EPMD ‘O’-rings. Maximum operating temperature 85°C.
Screw down pattern, angled solation valve with a dome type operating member, DZR brass body and an EPDM gasket and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower outlet elbows with brass bodies (chrome plated,with exception of model 27.076.LS0). Some models incorporate a shower handset holder. The outlet incorporates a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Intelligent water assist valve consisting of a motorised quarter turn shut off valve which operates in the event a leak on the supply pipe to which it is fitted. Maximum working pressure 10 bar. Cold water use only.
Range of in-line flow sensors with a plastic body, turbine and impeller case. Maximum working pressure 25.0 bar. Cold water use only.
Range of compact wall outlet assemblies with plastic bodies (chromium plated) and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Plug with nylon body and stainless steel shaft. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of booster sets with a stainless steel manifold system connecting 2 or 3 wholesome water pumps (For 2HELIX & 3HELIX models only). The set also includes spherical valves, and a non-return valve Maximum working pressure: 10.0 Bar Maximum operating temperature: 40°C
Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.
Range of black plastic bodied multistage, self or manually primed, high pressure centrifugal pumps with a stainless steel outer casing, plastic impellors, EPDM seals and ‘O’-rings. Maximum working pressure 8.0 bar. Cold water use only.
MBC 12-22WM & MBC 12-28WM models are wall mounted mains supply booster sets. They are supplied with two spherical isolation valves, a spherical bypass valve and two single check valve assemblies (suitable for backflow protection against Fluid Category 2). The check valve assemblies are to be installed in accordance with the manufacturers instructions, one upstream of the pump inlet and one after the bypass valve. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet and is housed within a wall mounted cabinet. MJ3 VM & MJ3 HM models are mains supply booster sets intended to be mounted on an expansion vessel (not supplied as part of the approval). They comprise of a pump, a suction and discharge manifold with bypass arrangement, and a spherical bypass valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet. Maximum working pressure 6.0 bar. Cold water use only.
Range of rotary vane (positive displacement) pumps with stainless steel bodies. Maximum working pressure 18.0 bar. Cold water use only.
Range of booster pumps with plastic bodies and impellers, EPDM ‘O’-rings and stainless steel inlet manifolds. The product incorporates a non-return valve. The ESYBOX MAX single models are also supplied with an optional 2” BSP (M) x 1¼” BSP (F) plastic inlet adaptor. Maximum working pressure 12.0 bar. Cold water use only.
Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.
Range of magnetic drive volumetric rotary vane pumps with a plastic housing and built-in relief valve. Maximum working pressure: 22 series models - 20.0 bar, 20 series models - 14.0 bar. Cold water use only.
Range of pump units with plastic bodies and impellers, EPDM ‘O’-rings, expansion vessel with an EPDM membrane and a carbon graphite/ceramic/NBR shaft seal (bt-ar 13 bx 4ff xp). Each pump inlet incorporates a non-return valve. Single versions are standalone pumps, twin versions also include stainless steel manifolds. Maximum working pressure 10.0 bar. Cold water use only.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
Range of self-priming pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of shower handsets and overhead showers with metal chromium plated bodies with. Models 20123 and 15185 are fitted with check valves at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Model 20127 is supplied with a flexable hose connection. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower arms and brackets with brass bodies (various finishes). Shower brackets incorporate single check valves cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum operating temperature 85°C.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Range of overhead shower outlets (chrome plated plastic bodies). Inlets incorporate a strainer. Maximum operating temperature 85°C
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings (280R/W model) or EPDM ‘O’-rings (286P/W model). The inlet of the 286P/W model incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted shower outlets (brass bodies), shower hoses and handsets available in various finishes (see model). The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of atmospheric steaming ovens having a 25 litre, 70 litres or two 25 litres capacity chambers. The water supply is controlled via a solenoid valve and incorporates a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar & maximum operating temperature 23°C.
Range of inline ‘Y’- patterned strainers with brass bodies & stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (various finishes), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener or aerator (expect models M5001 and M5002). The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating pressure 85°C.
Range of pillar taps incorporating brass bodies (chrome plated), non-rising spindle headworks (models 922031 & 922033) or quarter turn ceramic disc headowks (all other models). The spout outlet incorporates a flow straightner. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Page 12 of 158
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.