Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members and a locakble self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of wall mounted three hole, single outlet (fixed) combination tap assemblies with brass bodies (in various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see model). The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates either a plastic flow straightener or plastic aerator (see model). The invincible range is supplied with a plastic back nut, all other models are supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly with a brass body (various finishes - see model), incorporating quarter turn ceramic disc headworks with dome type operating members. The products are supplied with stainless steel braided EDPM lined flexible hose assemblies incorporating ¾” captive nut end connections for installation between the headworks and the spout. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 3.0 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever (20815882 model) or cross top (20815892 model) operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for installation between the side valves and the spout. The spout outlets incorporate a plastic aerator. The side valves are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Functional trim set (chrome plated), comprising of a ceramic cartridge headwork with a single lever operating member and a spout outlet. The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Functional trim set (chrome plated), comprising two quarter turn ceramic disc headworks with either single lever (models ending in 882) or cross top (models ending in 892) operating members and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Bath spout outlet with a brass body (various finishes) and a plastic aerator. Maximum operating temperature 60°C.
Range of deck mounted spout outlets (chrome plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum working temperature 60°C.
Range of wall mounted basin spouts (chromium plated brass). The spout incorporates a plastic flow regulator on the inlet and a plastic aerator on the outlet. Maximum operating temperature 60°C.
Range of expansion vessels incorporating composite plastic bodies and butyl diaphragms. Maximum working pressure 8.6 bar. Cold water use only.
Range of SUS316L & SUS304 stainless steel press fittings for use with stainless steel pipe manufactured to EN 10312. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of press fit fittings incorporating copper (GP5 models) or bronze (GP4 models) bodies and EPDM `O`-rings, for use with copper tube to EN 1057. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of dual flushing WC outletvalves with plastic bodies and silicone gasket. Cold water use only.
Range of WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of WC dual flush drop valves comprising of a plastic body, silicone seal and an internal overflow. The valve is operated via a push button or lever assembly for either full or reduced flush. Cold water use only.
Range of vertical vented cased copper cylinders with indirect coils. The secondary circuit incorporates a thermostatic mixing valve. The inlet consists of a ball valve with strainer, inline non verifiable single check valve and mini shock arrestor. Cylinder are supplied with a factory fitted immersion heater. Maximum working pressure - secondary 6.0 bar, primary 2.2 bar. Maximum operating temperature - secondary is 60°C, primary 85°C
Range of handwheel operated hemisphere valves with blue epoxy coated ductile iron bodies, stainless-steel disc, seat and stems, and EDPM seals Maximum working pressure 10.0 bar. Maximum working temperature 80°C.
‘E-WATER BLOCK’ self-closing valves with black plastic bodies and stainless-steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Copper corrugated hose. Maximum working pressure 10.0 bar. Maximum working temperature 90°C.
Range of plastic bodied quarter turn isolation valves, with EPDM rubber ‘O’-rings, seals and washers. The 52.009.100 model is operated by a hex key (not supplied), the 52.009.200 model is operated by a key (supplied). Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Appliance inlet group assembly comprising of EPDM gaskets, a plastic bodied Y-pattern strainer, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a dual layer hose with a PVC outer (grey) and PVC liner (black), a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of water meter couplings with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only
Appliance inlet group assembly comprising of an EPDM gasket, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a flexible reinforced hose assembly with a PVC lining and a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 5.0 bar. Cold water use only.
Range of hand wash and dryer units The flow is controlled by a solenoid valve activated via an infra-red sensor. The products are supplied with a non-verifiable double check valve assembly (suitable for backflow protection against Fluid category 3) for installation on the inlet. The double check valve assembly also incorporates a drain port, (located in between the cartridges), and an integral spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 50ºC.
Range of booster pumps with stainless steel bodies and impellers (AISI 304: AL-RED models or AISI 316: CP models), EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure: CP(m) 100-130-132-150-158 and AL-RED(m) 600-610-620 models: 6.0 bar. All other models: 8.0 bar. Maximum operating temperature 90°C.
Centrifugal pump with a plastic body, plastic impellers and NBR ‘O’-rings. The product includes an (integral) expansion vessel and the inlet incorporates a non-return valve (not suitable for backflow protection). Maximum working pressure 4.5 bar. Maximum operating temperature 50°C.
Single pump units with plastic bodies and impellers, EPDM ‘O’-rings, expansion vessel with an EPDM membrane and a carbon graphite/ceramic/NBR shaft seal (bt-ar 13 bx 4ff xp). Each pump inlet incorporates a non-return valve. Maximum working pressure 10.0 bar. Cold water use only.



Range of wall mounted shower elbows with brass bodies (chrome plated) incorporating single check valves cartridges fitted on the outlet (however, the complete product has not been fully tested to demonstrate it provides backflow protection).Maximum operating temperature 65°C.
Range of shower outlets with brass or stainless steel bodies (chrome plated) fitted with NBR ’O’-rings. Maximum operating temperature 65°C.
Range of shower arms with a brass body and various finishes. Maximum operating temperature 60°C.
Range of shower handsets with plastic bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of wall mounted compact shower panels with push button timed flow control. The inlet incorporates a plastic flow regulator and a stainless-steel strainer. Maximum working pressure 4.0 Bar Maximum operating temperature 60°C
Concealed installation set for use with wall mounted overhead shower outlets (brass body – various finishes). The inlet to the shower outlet incorporates a stainless-steel strainer, a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower arms and outlets with chrome plated brass bodies. The shower outlets incorporate plastic flow regulators at the inlets. Maximum operating temperature 85°C.
Range of shower hoses and handsets (various finishes - see model) with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of Y pattern strainers with a bronze body and stainless steel mesh. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.


Pillar tap incorporating a ceramic cartridge headwork (chrome plated brass body) with a single lever operating member. The spout outlet incorporates a flow straightener and flow regulator. The product is supplied with plastic backnuts Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps with brass bodies (various finishes - see model) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The 4102BD18 models incorporate a plastic flow restrictor on the inlet. The products are supplied with plastic and brass backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with either cross top or single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing tap assemblies (chrome plated brass) with spring loaded headworks and dome type or single lever (745440 model only) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, self-closing tap assemblies (chrome plated brass) with spring loaded headwork and dome type operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Self-closing tap for drinking water fountains (chromium plated brass) with dome type operating member. The spout outlet incorporates a stainless-steel strainer. The product is supplied with a metal back nut. Maximum working pressure 5.0 bar. Cold water use only.
Range of self-closing taps (chromium plated brass) incorporating spring loaded headworks with dome type operating members. The spout outlet of the 9000 model incorporates a plastic flow straightener. The products are supplied with a metal back nut. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C, except for the 9054SA model which is cold water use only.
Self-closing drinking fountain tap (chromium plated brass) with non-concussive headwork operated via a push button. The tap incorporates a metal shroud and is supplied with a metal back nut. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel interlocked shower hoses (various finishes) incorporating a PVC liner and EPDM gaskets. Maximum operating temperature 65°C.
Page 11 of 64
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.