Non-verifiable, double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a nickel plated, DZR brass body. The assembly incorporates an isolation valve and stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Drayton GRP range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.
Range of single hole, single outlet swivel nozzle combination tap assemblies (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with cross top operating members. The outlet incorporates a plastic aerator and the product is supplied with a lever type pop-up waste, not verified by test. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of single hole bidet combination tap assemblies (brass bodies - various finishes) incorporating a ceramic cartridge headwork and single lever operating member. The swivel nozzle outlet incorporates a plastic aerator and the product is supplied with a lever type pop-up waste – not verified by test. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of ½ turn ceramic disc headworks, with brass bodies and EPDM seals, for insertion into specifically dimensioned tap assemblies. Maximum working pressure: 5 Bar. Maximum operating temperature: 85°C.
Range of ceramic cartridge headworks with brass bodies and EPDM gaskets and O-rings. For insertion into specifically dimensioned bores. Maximum working pressure; 5 Bar Maximum operating temperature 60°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), models EMB10CP, EMB10BN, EMB10BB, EMB10MB, EMB10WH, CREPOCP & CREPOBN incorporate ceramic cartridge headworks, model (ARI10CP, ARI10BN, ARI10BB, ARI10MB & ARI10WH incorporates quarter turn ceramic disc headworks both with single lever operating members. The spout outlet is a pull-out spray type. The inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener or a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Deck mounted, single hole, single outlet fixed combination tap assembly (brass bodies – various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. This product also incorporates an additional spring-loaded quarter turn ceramic disc headwork with a single lever operating member for filtered cold water discharged from the spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Single-hole, single outlet (swivel) combination tap assembly (chrome plated brass body), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The products are supplied mounting kit that comprises of stainless-steel braided hoses and isolation valves that incorporate approved single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator or a plastic flow straightener. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating ceramic cartridge headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener or plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The cold only inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold inlet hose and the spout outlet incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 75.0°C
Range of wall mounted, two-hole, single outlet, (fixed) combination tap assemblies, (brass bodies – various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Model (TVW125003000xx) is supplied with a click type waste (verified by test). Maximum working pressure 10.0 Bar Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet fixed combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with dome or lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The inlets incorporate a stainless strainer and an approved single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65 °C
Range of combined bath filler and/or waste and overflow assemblies (see models) in various finishes. Open outlet use only Maximum operating temperature: 60ºC
Range of tap adaptors with chrome plated (brass or plastic) bodies. The outlet of some models incorporates a plastic flow restrictor. The side mount adaptors (except 90-001801) incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The side mount adaptors (except 90-001804) incorporate a piston type component which is intended to stop the flow to change the filter. All side mount adaptors and 90-001869 & 90-001873 Fixed Position Adaptors have a maximum working pressure of 5.0 bar. All other models are open outlet use only. Maximum operating temperature 60°C.
Range of exposed bath fillers (brass body, various finishes) incorporating a ceramic cartridge headwork, controlling both flow and temperature with a single lever operating member. The products incorporate integrated overflow and click type pop-up waste systems. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of swivel or fixed spout outlets (chromium plated brass) incorporating a plastic aerator. Open outlet use only Maximum operating temperature 60.0°C
Range of expansion vessels with fibreglass bodies and butyl diaphragms. Maximum working pressure: 8.6 Bar. Maximum operating temperature: 23 °C.
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of press fittings (brass bodies - various finishes) with stainless steel press (‘TH’ profile) collars and EPDM O-rings for use with “SOUTH PRESS” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
A range of black polyethylene electrofusion fittings from DN 20 to DN 1200 for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. A range of black polyethylene butt-welded fittings from DE 20 to DE 1200 fittings for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. Maximum working pressure: 20.0 bar for SDR 9 Maximum working pressure: 16.0 bar for SDR 11 Maximum working pressure: 10.0 bar for SDR 17. For above and below ground and cold water use only.
‘Safety’ range of PPS compression fittings for use with “Multi-Calor” multi-layered PEX/Al/PEX pipe. For above ground use only. Maximum working pressure 10bar. Maximum operating temperature 95 °C.
‘Pexalbrass’ range of brass press fittings for use with “PEXAL” multi-layered (PE-X /Al/PE-X) pipe. Joints are achieved via crimping tool for H (DN16, DN20, DN26, DN32), TH(DN16, DN20, DN26, DN32, DN40, DN50, DN63), U (DN16, DN20, DN26, DN32, DN40, DN50, DN63, DN75, DN90, DN110) profile. Maximum working pressure 10bar. Maximum operating temperature 95 °C.
Range of brass threaded fittings,. Above ground use only. Maximum operating pressure of 16.0 bar. Maximum operating temperature of 85°C.
Range of brass (CW617 or CW511L) press fit fittings (M-Type) for use with copper pipe manufactured to EN 1057. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
Float switch with plastic body. Maximum working pressure 1.2 bar. Maximum operating temperature 23°C.
Range of WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of WC single flush flapper valves with an ABS body. The valves are operated via a lever handle or a push button assembly and incorporate an internal overflow. Cold water use only
Range of near boiling hot water dispensers with stainless steel tanks and flow is controlled via float switch. Maximum working pressure 3 Bar. Maximum operating temperature 98°C.
Range of inline water meters with brass bodies (blue or red epoxy coating). The inlet incorporates a plastic strainer. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve. Models ending in ‘CGDM’ incorporate a single check valve cartridge and models ending in ‘CGDCVDM’ incorporate two, single check valve cartridges however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of electronic pump controllers with plastic bodies. Maximum working pressure 12.0 Bar. Cold water use only.
Range of pressure transducers with stainless steel bodies. Maximum working pressure 10.0 Bar, 20 Bar or 40 Bar. Maximum operating temperature 99°C.
Range of booster sets, incorporating a stainless-steel manifold system and between 2 and 5 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 16.0 Bar. Maximum operating temperature 25.0°C.
Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C
Shower handset with various finishes. Maximum operating temperature 65°C.
Shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Page 186 of 232
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.