Range of UV disinfection units. Maximum working pressure 6.9 bar. Cold water use only.
Ultra-violet disinfection unit comprising of a stainless-steel body and quartz sleeve. Maximum working pressure 8.0 bar. Cold water use only.
Electronically controlled, commercial ion exchange water softeners. Maximum working pressure 7.0 bar. Cold water use only
‘V-PET#1600 Gray F’. Factory applied, dark grey coloured epoxy resin powder coating. Apply as per manufacturer’s instructions ‘ref.no. VP1600-PD-170412’, dated '12th April 2017'. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Electrocoat EP812 Blue'. Factory applied, blue coloured, two-part epoxy coating consisting of a base and hardener. Mix base and hardener in a volume ratio of 3:1 and apply as per manufacturer's data sheet 'ECL / TDS / EP 812 - BLUE, RAL 5017', issue date '12-Jan-13', version '03', revision date '25-Sept-14'. Cure for 1 hour@60°C followed by 7 days@28°C. For use with water up to 23°C. From March 2024 the material is for use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'YT425'. Factory applied, grey coloured Portland Cement Mortar. Mix cement, sand and water in a 2:1:0.4 mass ratio and apply as per manufacturer's instructions issue 'AYYT01' dated '2023.3.16'. Cure for 12 hours@55°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'INOFLAR™ 1005, INOFLAR™ 1011, INOFLAR™ 1020 & INOFLAR™ 1125'. Off-white coloured, injection moulded PVDF materials. For use with water up to 85°C.
'0612 HNBR'. Yellow coloured (opaque), injection moulded HNBR 'O' rings. Shore hardness 70. Tested in-radius size 1.31mm. For use with water up to 85°C.
'Hinton Solvent Cement HSC125 & HSC250'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions 'Rev00 02062023'. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water only
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by electronic or manual actuation. Maximum working pressure 10.0 bar. Cold water use only
Range of Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. Maximum working pressure -10 Bar Maximum operating temperature - cold water use only Models T1910 & T1911 can now incorporate a T8702 flush valve. Maximum working pressure 10 Bar, cold water use only.
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
Wall mounted, three-hole, single outlet, fixed combination tap assembly (chrome plated brass body), incorporating a ceramic cartridge headwork with a single lever operating member. The product is supplied with a shower handset holder that incorporates a manual diverter and a cascade type spout outlet. Maximum working pressure 5.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of quarter turn ceramic disc headworks with brass bodies and NBR ‘O’ rings, for insertion into specifically dimensioned bores. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings for insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of push button ceramic cartridge headworks with a plastic body and EPDM seals. For insertion into specifically dimensioned tap assemblies Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model), incorporating either a ceramic cartridge headwork or ceramic disc headworks with various operating members (see model). The spout outlet of some models incorporates a plastic aerator (specific models only - see model). Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a waterfall type which also incorporates a stainless-steel mesh on the F7 and F9 prefix models. Maximum operating pressure 5.0 bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure: See Models
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (black or chrome plated), incorporating ceramic cartridge headwork and single lever operating member. Spout outlet incorporates a plastic aerator. Maximum working pressure 5- 10.0 bar (see models). Maximum operating temperature 60°C – 85°C (see models).
Range of single hole, single outlet, (swivel) combination tap assemblies, (brushed stainless steel brass bodies). Incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. The products are supplied with metal back nuts. The inlets are supplied with stainless steel strainers. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C
Range of single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever type operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assemblies (brass body - varies finishes incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies, (brass bodies, various finishes - see model), incorporating a ceramic cartridge headworks with either a single lever operating member or dome type operating member (F9482A-X model only). Thee spout outlet incorporates a plastic aerator (except model F8122A). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Wall mounted bar type thermostatic bath shower mixer (chromium plated brass), incorporating a diverter valve controlling the flow to either the spout outlet or shower outlet with a single lever operating member with manual override. The temperature is controlled independently via a thermostatic cartridge using a single lever or dome type operating members with a manual override. Both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
A range of two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to a shower outlet. The spout outlet incorporates plastic aerators or flow straightener and is supplied with metal backnuts. The products are supplied with a shower hose, handsets and metal backnuts. Maximum working pressure 10 bar.
Range of wall mounted, two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass), incorporating a manual diverter controlling the flow to the overhead or hand shower and a thermostatic cartridge controlling the temperature with dome operating member incorporating a manual override button. The spout outlet incorporates quarter turn ceramic disc headwork which diverts between the spout and shower outlets and the spout outlet incorporates a plastic aerator. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with shower hose or shower outlets. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, double outlet, fixed combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with metal back nuts. Maximum operating pressure 6 bar. Maximum operating temperature 85°C
Range of wall mounted, three-hole, metal, single outlet (fixed), combination tap assemblies (concealed brass body, various finishes - see model), incorporating quarter turn ceramic disc headwork with single lever, cross top or dome type operating members (see model). The spout outlet incorporates a plastic aerator (F7 & F9 prefix models only). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of three-hole, single outlet (swivel) combination tap assembly incorporating brass body - various finishes) and quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Spout outlet, (chrome plated brass body) incorporating EPDM ‘O’ rings. The outlet incorporates a plastic flow straightener.
Non-metallic materials and components comply with BS6920 at 50°C
Range of wall mounted spouts with a brass body (various finishes, see model). The outlet incorporates a plastic aerator. Maximum operating temperature - 60°C
Range of QSL stainless-steel expansion bellows with either threaded or flanged end connections. Maximum working pressure: See models. Maximum operating temperature 99°C.
‘Buteline Polybutylene Plumbing System’ comprising of DZR brass or plastic fittings for use with Buteline polybutylene, EVOH barrier pipe (white or grey). Maximum working pressure 16 bar @ 23°C, 7.0 Bar @ 82°C.
Stainless steel press fittings for use with 316L & 304 stainless steel tube incorporating EPDM ‘O’ rings. The fittings and tube are assembled using a crimping tool. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
“D” Range of stainless steel (304S31/316S11) press fittings for use with ‘DPX’ series 1 & 2 stainless steel (304S31/316S11) pipe. The fittings and tube are assembled using a crimping tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of JG Twist & Lock Speedfit push-fit fittings for use with JG Speedfit Layflat Polybutylene Barrier Pipe (BPB Pipe to BS EN 7291-2:2010), 'BPEX' Barrier Pipe.(BPEX Pipe to BS EN 7291-3:2010) and Copper Pipe to BS EN1057:2006 Max working pressure & operating temperature: 12.5 Bar at 20°C 6.0 Bar at 83°C
Range of copper and brass press-fit fittings with HNBR o-rings, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of DZR brass push fit fittings for use with copper pipe (manufactured to BS EN 1057), PB pipe (manufactured to BS7291-2) and PEX pipe (manufactured to BS7291-3). Maximum working pressures and operating temperatures: 12.5 @ 20°C, and 3.0 bar @ 92ºC.
PLAS-FIT range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of Conex >B< press fittings incorporating copper & brass bodies for use with copper tube (manufactured to EN1057). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
‘Trustlene’ range of electrofusion and spigot fittings, with PE100 or brass bodies, for use with SDR11 PE100 pipe (manufactured to IS 4984: 2016). For use above and below ground. Maximum working pressure 16.0 bar. Cold water use only.
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C
DZR brass elbow fitting. Compression connection to be used with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Page 18 of 50
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.