Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of bib taps with DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of self-closing tap assemblies (chrome plated brass) with spring loaded headworks and dome type or single lever (745440 model only) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
PEX lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
EPDM lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of multi-layered flexible hoses (TPE inner liner/PVC middle/PVC outer with polyester braiding in-between) and stainless-steel braided EPDM flexible hoses. The hoses are supplied with a variety of end connections incorporating brass barbed hose inserts or white plastic barbed hose inserts. The hoses may also incorporate a servicing valve (see model). The push fit connectors are to be used with copper pipe (Manufactured to EN1057), PB pipe (Manufactured to BS EN21003) & PE-x pipe (manufactured to BS EN7291-3). Products shown with a “P” suffix (eg. WFLX15P, FLX43P) are a prepacked variant of the original product eg. WFLX15, FLX43. Products shown with a “SB” suffix (eg. FLX15P-SB, WFLX28-SB) are a reduced box quantity of an existing product. Maximum working pressure and operating temperature: 12.0 bar @ 20°C and 6.0 bar @ 65°C.
Wall mounted, manually operated blending valve, (brass body with a chromium plated brass trim set), incorporating a ceramic cartridge headwork with a single lever operating member controlling temperature and flow, and a manual diverter controlling the flow to the shower hose and handset or a secondary shower outlet. The product is supplied with a shower hose and handset. The handshower outlet connection and the shower handset inlet both incorporate an approved check valve cartridge, however the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower mixing valves with brass bodies (various finishes - see model) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Both inlets incorporate a combined NBR washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower blending valves incorporating brass bodies and an external trim set (various finishes). Flow is controlled to each shower outlet via individual ‘detent’ (push to on push to off) headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose, shower handset, riser rail and overhead shower outlet. The product is also supplied with two loose plastic flow regulators for installation between the valve and the shower hose, as well as on the inlet to the overhead shower. Maximum working pressure 5.0 bar. Maximum operating temperatures: shower handset 50°C, all other items 65°C.
Concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7 bar. Maximum working temperature 65°C.
Range of concealed, wall mounted, thermostatic mixer valves with brass bodies (various finishes) with 1 - 6 outlets. Flow is controlled to each outlet by ‘detent’ (push to on push to off) headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate a combined plastic washer and stainless steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome operating member and manual override button. The temperature is controlled by a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a 2-way manual diverter valve controlling and diverting the flow between an overhead shower and a shower outlet with dome type operating members, model (34458892) is supplied with cross-top operating members. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the overhead shower incorporates a stainless steel strainers and flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of temperature and pressure relief valves incorporating a DZR brass body & EPDM membrane. See model for maximum working pressure. Maximum operating temperature 90°C.
Ceramic disc diverter cartridge with on/off function incorporating a plastic body, NBR ‘O’-rings and silicone seals. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of pre-set, spring loaded, angled pressure relief valves with plastic body and EPDM diaphragm. The valves are fitted with rotary type easing gear . For maximum working pressure please refer to model. Maximum operating temperature 99°C.
Range of pre-set angled pressure relief valves for use on primary closed circuits, incorporating DZR brass bodies, EPDM diaphram and EPDM or NBR ‘O’-ring. For maximum working pressure please refer to model. Maximum operating temperature 99°C.
Range of latching and non-latching solenoid valves with brass bodies and an integral stainless-steel strainer. X262513141 (abc) (dd) models have a NBR ‘O’-Ring and diaphragm, all other models have an EPDM ‘O’-Ring and diaphragm. Maximum working pressure: see model. Maximum operating temperatures: X262513141(abc)(dd) models 65°C, all other models 85°C.
Range of spherical valves (nickel plated) brass bodies with single lever operating members, (chromium plated) brass ball and PTFE seat. Maximum working pressure 40.0 bar (Models 124-1027 CST, 124-1028 CST and 124-1029 CST) Maximum working pressure 25.0 bar (Models 124-1030 CST and 124-1031 CST) Maximum working pressure 16.0 bar (Models 124-1032 CST and 124-1033 CST) Maximum operating temperature 85°C.
Range of quarter turn, lever handle or butterfly operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating ductile iron epoxy coted bodies and with EPDM ‘O’-ring seals and discs. The valves are operated via a non-rising spindle with a hand wheel operating member Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.



Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of polyethylene pressure vessels with spun (blue) fibre glass casing. Maximum working pressure 10.0 bar. Maximum operating temperature 50°C.
‘Karumel EX4412 Blue & Grey’. Factory applied, blue or grey coloured, epoxy resin based powder coating. Apply and cure as per manufacturer’s instructions reference 'PCA-21062901', issued August 2021. For use with water up to 85°C.
'DAT-01'. Factory applied, grey coloured cement mortar. Mix cement, sand & water in a weight ratio of 34.4:44.9:20.7. Cure for 8 hours@50°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Polyurea FA 1044'. Factory applied, two-component, beige coloured polyurea coating. Mix parts A and B in a 1:1 volume ratio apply as per manufacturer's TDS '07/2015 Rev.00'. Cure for 96 hours@25°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘0250-35 (50A), 0260-35 (60A), 0270-44 (70A), 0280-22 (80A) and 0290-11 (90A)’. Black coloured, compression moulded EPDM materials. Shore hardness between 50A & 90A. Tested in-radius size 1.0mm. For use with water up to 23°C.
'LP4411ANAT, LP37ANAT, LP4611ANAT & LP4811ANAT'. Natural (off-white coloured), compression moulded silicone rubber materials. Shore hardness 40°, 60° and 80° respectively. Tested in-radii sizes between 1.0mm and 2.0mm. For use with water up to 85°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies comprising of a concealed brass body and a separate spout and trim set (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The inlets (within the) concealed body incorporate a plastic filter and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
A range of single-hole, single outlet (fixed (model 62816) or swivel (models 63407)) electronically controlled tap assemblies with brass bodies in various finishes (see models). Flow is controlled by a solenoid valve activated via an infra-red sensor and a ceramic cartridge with a single lever operating members controlling both the flow and temperature for all models excluding 62816, which uses a mixer to control the temperature only with a single lever operating member. The spout outlets incorporate plastic aerators. All models (excluding 63407) incorporate a separate approved check valve cartridge on the inlet, verified by test (suitable for backflow protection against Fluid Category 2), The inlets of all models incorporate stainless steel strainers. Maximum working pressure 5.0 bar Maximum working temperature 60°C.
Single-hole, single outlet, swivel electronically controlled tap assembly with a brass body in various finishes (see model). Flow is controlled by a solenoid valve activated via an infra-red sensor and a ceramic cartridge with a single lever operating member controlling both the flow and temperature. The spout outlet incorporates a pull-out spray with a plastic aerator. The inlets incorporate approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 2), and a stainless-steel strainer Maximum working pressure 5 bar. Maximum working temperature 60°C.
Single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. The product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of aerators with plastic bodies and filter screens. Maximum operating temperature 60°C
Range of thermostatic cartridges with brass bodies and EDPM ‘O’-rings. All models expect XB-12T incorporate stainless steel strainers. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic disc headworks and single lever operating members. The cold inlet to the tap incorporates incorporates an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2). The inlet of hose to the pull-out spray incorporates an approved check valve cartridge which has not been fully tested to demonstrate it provides backflow protection. The outlet of pull-out spray incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks with either a single lever, cross top or dome type operating member (see model). The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a push on/off headwork with rotary temperature control using dome type lever operating member. Both inlets incorporate stainless steel strainers an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Some models are supplied with lever type pop up waste (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet incorporates an approved check valve cartridge, verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies, brass bodies (various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Products are supplied with approved pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of floor mounted, single outlet (fixed) combination tap assembly with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet with a single lever operating member. The shower outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with a shower hose and shower handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member and a self- cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The outlet from the self-cancelling diverter incorporates an approved check valve cartridge (except model 31 930 xx0), Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet incorporate an approved check valve cartridge, verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating quarter turn ceramic disk headworks with single lever operating members. The cold water inlets is supplied with a chrome plated brass adapter incorporating an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate plastic aerators. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork and single lever operating member.The spout outlet incorporates a plastic aerator Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Deck mounted two-hole, single outlet, fixed combination tap assembly (brass body, various finishes - see model), incorporating ¼ turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with various operating members (see models). The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 2 of 15
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.