Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with silicone or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C for models 30.4010.0 and 40.4011.0. Maximum operating temperature 60°C for models 30.4043.0 and 30.4094.0.
Range of ceramic cartridge headworks with a plastic body and EPDM ‘O’-rings to be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks incorporating plastic bodies and silicone ‘O’-rings, to be inserted into specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 70°C.
Range of ceramic cartridge headworks with plastic bodies incorporating silicone seals for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of CA43 thermostatic cartridges incorporating plastic bodies and stainless steel filters. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes, see model). Incorporating ceramic cartridge headworks, and single lever operating members. The inlets incorporate flow strainer and the spout outlet incorporates a plastic flow straightener. Can be supplied with our without a pop up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, electronically operated combination tap assemblies (chromium plated brass) incorporating a solenoid valve controlling the flow which is actuated via in infrared sensor. The spout outlet incorporate a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate either a plastic flow straightener or aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (in black or chrome finishes) with brass bodies. Incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Some models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating a ceramic cartridge headwork with a single lever (Absolute range) or dome type (Engineer & Illustrious range) operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork and single lever operating member with self- cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The diverter outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chromium plated), incorporating a ceramic cartridge headworks and single lever operating member. The outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes), incorporating a quarter turn ceramic cartridge headwork and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Model 1002137653_N199998998 is supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a non-rising spindleheadwork with crosstop type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, wall mounted single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating arising spindle headworks and cross top operating member. Maximum working pressure 8.6 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating a non-rising spindle headwork with a dome type operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass & matt black finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of exposed wall mounted two-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a two-way manual diverter controlling and diverting the flow between the spout outlet and an overhead shower (not supplied) and a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member incorporating a manual override button. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet (fixed) bath shower mixers with brass bodies (various finishes), incorporating a manual diverter controlling and diverting the flow between the spout outlet and an overhead shower. Temperature is controlled independently via a thermostatic cartridge with dome type operating member with manual override button. The spout outlets incorporate a plastic aerator. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass & matt black finish) incorporating a quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlets incorporate a plastic flow straightener and the products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member and self-cancelling diverter to shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
“Plimat PVC-U Fittings BS Inch and PVC-U Fittings Threaded” range of PVC-U solvent cement or threaded fittings for use with “Plimat PVC-U BS inch pipe” (manufactured to EN1452-2). Maximum working pressure 15.0 bar for solvent cement connections and 10.0 bar for fittings that only include/also include a threaded connection. Cold water use only.
Uponor S-Press press fittings, Uni-X & Uni-C compression fittings for use with Uponor MLC pipe. Maximum working pressure 10.0 bar, maximum operating temperature 70°C.
‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
‘CB ISR’ range of capillary fittings with internal solder rings, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of compression fittings with polypropylene bodies, nuts, acetal grip rings, EPDM ‘O’-rings and plastic pipe liners for use with MDPE pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
“Plimat ABS Fittings BS Inch and ABS Adaptor Fittings” range of ABS solvent cement or threaded fittings for use with “Plimat ABS pipe”. Maximum working pressure: 15.0 bar (fittings with ½” - 4” solvent cement connections), 9.0 bar (fittings with 5” or 6” solvent cement connections, with or without threaded connecitons), and 10.0 bar (fittings with threaded connections and ½” - 4” solvent cement connections). Cold water and above ground use only.
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
End Feed Range copper fittings for use with copper tube. For above and below ground use Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of dual flush WC syphons incorporating a polypropylene body, stainless steel C link and a LDPE sealing washer. The valve is to be operated via a handle lever. Cold water use only.
Range of indirect heat interface units providing heating and instantaneous hot water. The hot water and space heating is provided via two separate plate heat exchangers. The space heating circuit incorporates an expansion vessel and expansion relief valve (set @ 3.0 bar). The primary circuit only is supplied with isolation valves on the flow and return. Maximum working pressure primary 16.0 bar. Maximum working pressure space heating 2.5 bar. Maximum working pressure secondary hot water (DHW) 10.0 bar. Maximum operating temperature primary 75°C. Maximum operating temperature space heating 85°C. Maximum operating temperature secondary hot water (DHW) 65°C.
Range of stainless-steel plate heat exchangers with copper brazing. Maximum working pressure 30.0 Bar. Maximum operating temperature 100°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
Plastic bodied flow sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower hoses and riser rail with chromium plated brass bodies, incorporating EPDM ‘O’-rings. Maximum operating temperature 85°C.
Page 1 of 83
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.