Range of dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush. Cold water use only
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve and a non-return valve (not suitable for back flow protection). Model MD1010101BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Range of water meter manifolds with a plastic body and a spherical valve at the inlet. Models MB2012525DM & MB2010303DM incorporates two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection Model MB201010BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Stainless steel bodied sensor with EPDM ‘O’-ring. Maximum operating temperature 90°C.
Range of flow sensors with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C
Range of wall mounted shower arms and shower handsets with brass bodies (various finishes), the inlets to the shower handsets incorporating a flow restrictor. Maximum operating temperature 60°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Range of circulation valves and flow sensor valves with EPDM seals and O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90ºC.
Range of submersible pumps with stainless steel bodies, impellers and shaft. The XPW range incorporates a strainer cowl on the suction end of the pump. The XPWA range features a stainless head which provides a threaded connection instead of the strainer. Cold water use only.
Dutypoint ‘VS’ range of cold water supply booster sets, incorporating 2 to 8 pumps with a modular stainless steel manifold system. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels.. Maximum working pressure 10.0 bar. Cold water use only.
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 11.03 Bar (Bypass) and 7.0 Bar (Operating).
Range of pumps with either brass or stainless-steel bodies, stainless steel impellor and NBR ‘O’ rings. 20 & 33 brass series have a maximum working pressure of 16.0 bar. 33 stainless-steel series has a maximum working pressure of 20.0 bar. 22, 24 ,26, 38, 31, 32 & 34 series have a maximum working pressure of 20.0 bar. Cold water use only.
Range of shower handsets and shower heads chrome plated plastic bodies and built in combined flow restrictors/approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models added March 2023 are available in various finishes, see model.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets and shower heads with chromium plated ABS bodies (models A111101 & A121510WT is not chromium plated). Maximum operating temperature 75°C.
Range of shower outlets with chromium plated bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. From July 2023, model P61400 can also be supplied without the check valve at the inlet. Maximum operating temperature 70°C.
Shower hose incorporating an EPDM liner and grey PET outer layer. Supplied with EPDM washers. Maximum operating temperature 70°C.
Range of shower outlets with chromium plated bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower outlets incorporating brass bodies (various finishes). Maximum operating temperature 60°C.
Range of wall or ceiling mounted overhead shower outlets (chromium plated brass) and shower arm. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of in-line “Y” patterned strainers with brass bodies incoroporating NBR ‘O’-rings and stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Drain cock elbow incorporating a DZR brass body with EPDM ’O’-rings (ZELB250445 model) or NBR ‘O’-rings (ZELB250446 model added July 2022). Both models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressures: ZELB250445 model - 10.0 Bar. ZELB250446 - 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass) with non-rising spindle headworks and cross type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (chromium plated) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of stainless steel braided PE-X lined flexible hose assemblies incorporating NBR washers and various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Platinox SLP’ range of stainless steel braided silicone lined flexible hose assemblies with a variety of end connections (see size). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.
Wall mounted concealed thermostatic shower valve, with a single sequential headwork controlling both flow and temperature. A manual diverter controls the flow between a shower handset or overhead shower. The inlets incorporate a single check valve however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of wall mounted, concealed, manual blending valves (chromium plated brass) incorporating a ceramic cartridge headwork, with a single lever operating member, controlling both flow and temperature. Model 36011660 is supplied with a shower hose and handset. The outlets incorporate an approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, manually operated blending valves with brass bodies (various finishes), incorporating ceramic cartridge headworks with either single lever (6900XX/METAL only) or dome type (all other models). The product is supplied with a shower hose and handset. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed shower valves (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The shower outlet incorporates an approved single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Products are supplied with overhead shower outlet and shower hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic mixers incorporating a brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 1.1900.018 is supplied with a shower handset and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted thermostatic mixers incorporating brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with a shower hose, shower handset and shower rail. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Range of wall mounted thermostatic shower valves incorporating chrome plated brass bodies. Product is supplied with a shower hose, handset and riser rail and over head shower. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of ceramic disc diverter valve headworks with plastic bodies for use in specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ‘J2 10 series’ of equilibrium float valves with cast iron (epoxy coated) bodies and EPDM seals. Available with either standard or extended arms. Maximum working pressure 10 bar. Cold water use only.
Range of equilibrium float operated valves with a stainless steel body and float (chrome plated), and a silicone seat. Maximum operating pressure 10.0 bar. Cold water use only.
Range of wall mounted flow control valves and trim kits (various finishes) with brass bodies incorporating a quarter turn ceramic disc headwork with various operating members (see model). The outlet of all models, except for the 38 882 xxx AXOR Uno model, incorporates a single check valve cartridge, (verified by test suitable for backflow protection against Fluid Category 2). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of spring loaded, resilient trim, non-return valves (blue epoxy coated cast iron body), with bronze bushing, stainlesss steel spring and disc, and EPDM seat. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pilot operated pressure reducing valves with blue epoxy coated ductile iron bodies, stainless steel filter, EPDM ‘O’-rings and diaphragm. The valve has an adjustable pressure reducing facility controlled via a pilot valve, with auxiliary components including stainless steel tubing and fittings, and stainless-steel spherical valves. Maximum inlet supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range of 0.6 - 6.0 bar. Maximum operating temperature 50°C.
Range of pilot operated pressure reducing valves with blue epoxy coated ductile iron bodies, stainless steel filter, EPDM ‘O’-rings and diaphragm. The valve has an adjustable pressure reducing facility controlled via a pilot valve, with auxiliary components including stainless steel tubing and fittings, and stainless steel spherical valves. Maximum inlet supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range of 0.6 - 6.0 bar. Maximum operating temperature 50°C.
Range of plastic bodied normally closed latching solenoid valves. The 42424000 model is supplied with an additional brass housing. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Spherical valve incorporating a brass body and ball, PTFE seat, EPDM and NBR ‘O’-rings. Maximum working pressure 10.0 bar. Cold water use only.
Range of spherical valves incorporating DZR brass bodies and balls (nickel plated), EPDM ‘O’-rings, PTFE seats and red or blue coloured lever type operating members. Maximum working pressure 16.0 bar for compression models Maximum working pressure 40.0 bar for 1¼”-2” RP Female & pressfit models Maximum working pressure 50.0 bar ½”-1” RP Female & pressfit models. Maximum operating temperature 85°C.
Page 8 of 82
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.