Telford Copper & Stainless Cylinders Ltd Approvals


#1907057

Solar twin coil range of stainless steel indirect hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish, expansion vessel and a drain valve also comes supplied. Maximum operating pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 3.0 bar. Maximum operating pressure solar circuit 5.5 bar. Maximum operating temperature 65˚C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1907057
Expiry date:
31/07/2024
Size:
25 litre, 90 litre, 150 litre, 170 litre, 200 litre, 250 litre, 300 litre
Marking:
Telford, model, pressure, capacity and technical info on adhesive label on body
Installation Requirements:
R001 R140 R530 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20OC and 45 OC. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
ornado Direct 3.0 90 litre Tornado Direct 3.0 125 litre Tornado Direct 3.0 150 litre Tornado Direct 3.0 170 litre Tornado Direct 3.0 200 litre Tornado Direct 3.0 250 litre Tornado Direct 3.0 300 litre Tornado Indirect 3.0 90 litre Tornado Indirect 3.0 90 litre Tornado Indirect 3.0 125 litre Tornado Indirect 3.0 150 litre Tornado Indirect 3.0 170 litre Tornado Indirect 3.0 200 litre Tornado Indirect 3.0 250 litre Tornado Indirect 3.0 300 litre Tornado twin coil 3.0 170 litre Tornado twin coil 3.0 200 litre Tornado twin coil 3.0 250 litre Tornado twin coil 3.0 300 litre
Factor:
Telford Copper and Stainless Ltd.
Company Name
Telford Copper and Stainless Ltd.
Address
Furrows Business Park Haybridge Road Wellington
Postcode
TF1 2DF

View All Listings by this Company
Manufacturer:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF

View All Listings by this Company

Print This Approval


#2103025

Range of “Tempest” Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103025
Expiry date:
31/03/2026
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Telford solar on label. Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Model:
TSMIXXX - Tempest indirect XXXL single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMIXXX/S - Tempest indirect XXXL twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L, 400 = 400L, 500 = 500L. TSMDXXX - Tempest direct XXXL electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L, 125 = 125L, 150 = 150L, 170 = 170L, 200 = 200L, 250 = 250L, 300 = 300L.
Manufacturer:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF

View All Listings by this Company

Print This Approval


#2103039

'Hurricane' range of Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2103039
Expiry date:
31/03/2026
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 1” BSP (F) Solar circuit: 1” BSP (F)
Marking:
Hurricane, Telford stainless and technical information including capacity and pressures on adhesive label on body.
Installation Requirements:
R001 R140 R360 R530
Model:
HURIXXX - Hurricane indirect single coil unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX/S - Hurricane indirect twin coil boiler & solar unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 170 = 170L 200 = 200L 250 = 250L 300 = 300L 400 = 400L 500 = 500L HURIXXX - Hurricane direct electric only unvented cylinder vertical. XXX denotes the capacity in litres, and is replace with any of the following: 090 = 90L 125 = 125L 150 = 150L 170 = 170L 200 = 200L 250 = 250L 300 = 300L
Factor:
Telford Copper & Stainless Cylinders Ltd
Company Name
Telford Copper & Stainless Cylinders Ltd
Address
Unit 22 Furrows Business Park Haybridge Road
Postcode
TF1 2DF

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.