Overhead ceiling or wall mounted (depending on shower arm) shower outlet with chrome plated plastic body, EPDM o-rings and a plastic flow restrictor at the ball joint. Maximum working pressure: Open outlet. Maximum operating temperature: 60°C.
Range of wall or ceiling mounted shower outlets (chromium plated brass). All models except SH5010 incorporate a flow regulator. Open outlet use only. Maximum operating temperature 65 °C.
Range of showerheads with a plastic body (various finishes - see model) and brass connections. The A7889, A7890 and A7891 models incorporate two solenoids controlling the flow to the spray plate or a central plastic aerator. The showerhead inlet also incorporates a plastic flow regulator (except for the A7889 models). Open outlet use only. Maximum operating temperature 60.0°C
EASO range of shower head and hand showers, with ABS bodies and chromium plated finish. Open outlet use. Maximum operating temperature - 65 °C.
Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of shower handsets with (plastic bodies - various finishes) incorporating a plastic flow restrictor in the inlet. Open Outlet use only Maximum operating temperature 60.0°C
Range of Y pattern strainers having either brass (899ST range) or bronze (900 range) bodies and PTFE seat washers. Maximum working pressure 20.0 Bar (Model 900), Maximum working pressure 32.0 Bar (Model 899ST). Maximum operating temperature 100.0°C.
Range of drain valves with a brass bodies, spindle and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of pillar taps, (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork with a cross top operating member. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of stainless-steel interlocked shower hoses and shower hose extension pieces (smaller length versions) incorporating PE/EPDM and PEX inner tube materials. Available with various surface finishes and end connectors. For further details see model section. Maximum working pressure open outlet use. Maximum operating temperature 85.0°C
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless steel inter-locked shower hoses incorporating PVC linings in various finishes. Maximum operating temperature 65°C.
Ultraflow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Range of Ultraflow Air bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added January 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection). Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of Compress 5800i AW vertical cased and insulated indirect unvented stainless steel hot water storage cylinders fitted with a Caleffi 309508 CST temperature and pressure relief valve set at 10 bar & 90°C, and supplied with a Caleffi inlet control group consisting of in-line pressure reducing valve (set at 3.5 bar) and pressure relief valve (set at 6 bar) and incorporates an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2). The cyclinders also supplied with an 18L expansion vessel and Intatec filling loop assembley (FL12041510). Maximum working pressure 10 bar. Maximum operating temperature 80°C.
Range of manually operated flow control valves with (brass bodies - various finishes), incorporating either a non-rising spindle headwork or (quarter turn ceramic disc headwork model 16 973 180 only) with cross top, lever or dome type operating members. Maximum working pressure; 10Bar Maximum operating temperature 70°C
Wall mounted thermostatic shower valve (chrome plated brass body), incorporating a non-rising spindle headwork controlling the flow. The temperature is controlled independently with a thermostatic cartridge, both using single lever operating members. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower kit that consists of a shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted thermostatic bar shower mixers with brass bodies, incorporating a thermostatic cartridge controlling the temperature and non-rising spindle headwork controlling the flow. The inlets incorporate stainless steel strainers and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of T-type thermostatic mixing valves with brushed chrome plated DZR brass bodies for use with copper pipe (manufactured to BS EN 1057). All inlets incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a single sequential headwork with a single lever operating member. The inlets incorporate a concentric isolation valve, plastic flow regulator & stainless-steel strainer. The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of T-Type thermostatic mixing valve (chromium plated brass). For use with copper pipe to BS EN1057. Maximum working pressure; 10 Bar Maximum operating temperature 85°C.
Range of thermostatic blending valve (chromium plated brass). The inlets incorporate stainless steel strainers and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted bar type shower mixing valve (brass body, various finishes - see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The hose outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of concealed, wall mounted thermostatic blending valves with brass bodies (chromium plated trim sets). The products consist of a two-way diverter and a thermostatic cartridge controlling the temperature. All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 90°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 100°C.
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc headwork which controls the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of wall mounted, thermostatic bar shower mixers (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork that controls the flow with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Models 483841 incorporate a half turn ceramic disc headwork that diverts the flow to an overhead shower or shower handset. Both inlets incorporate an approved check valve cartridge and stainless steel strainers however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models 248683 & 287697 Maximum working pressure 10 bar. Maximum operating temperature 65 C. Model 483841 Maximum working pressure 5 bar. Maximum operating temperature 60 C.
Range of T-type thermostatic mixing valves with brushed chrome plated DZR brass bodies. Each inlet incorporates a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. Compression connections are for use with copper pipe (manufactured to BS EN1057). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Combined temperature and pressure relief valves pre-set at 7.0 bar with a DZR brass body. Maximum operating temperature 90°C.
Range of plastic, ceramic disc diverter valves. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of eccentric plug valves with blue epoxy coated ductile iron bodies, PTFE washers a stainless steel plug which is fully encapsulated with EPDM. Maximum working pressure 16 Bar. Maximum operating temperature 80°C.
Range of non-return, swing gate valves with bronze, DZR brass or brass bodies and DZR brass, bronze or brass discs. Maximum working pressure 20.0 bar or 16.0 bar (please refer to model) Maximum operating temperature 85°C.
Range of in-line, manually adjustable pressure reducing valves with nickel plated DZR brass body. Maximum inlet supply pressure 25 bar. Maximum operating temperature 80°C
533 series of in-line, manually adjustable pressure reducing valves (DZR brass or brushed chrome plated DZR brass bodies) incorporating a stainless-steel strainer. All models except 533159 are supplied with a pressure gauge. Models with compression connection are for use with copper tube (manufactured to BS EN 1057). Maximum supply pressure 16.0 bar. Outlet pressures between 1.0 – 6.0 bar. Maximum operating temperature 40°C.
Range of adjustable, in-line pressure reducing valves with DZR brass bodies, incorporating a spring loaded EPDM diaphragm and a gauge port. The products incorporate an integral stainless steel strainer. The outlet pressure range is adjustable between 1.0 and 6.0 bar. Maximum inlet supply pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 40°C
Range of spherical valves with a brass body and PTFE seats. The products incorporate a lever or butterfly type handles. Maximum working pressure 30.0 bar. Maximum operating temperature 85°C.
Range of lever or butterfly operated spherical valves with brushed chromium plated brass bodies, chromium plated brass ball and PTFE seat. Maximum working pressure model K656: ¼” to ½” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Model K6566 model: ¼” to ⅜” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Models K8912 , K8913 & K6568 models: ¼” to ⅜” = 64.0 bar. Maximum operating temperature 99°C.
Range of spherical valves with either brass (UW24905 & UW24907 models) or nickel plated (UW24809, UW24906, UW24933, UW24908 & UW24934 models) brass bodies with chrome plated brass ball and operated via lever, butterfly type handle or screwdriver slot. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Thermostatic circulation valves incorporating DZR brass bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 90°C.
‘Aquastrom’ range of regulating valves with brass bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 90.0°C
Range of regulating valves with blue epoxy coated ductile iron bodies incorporating EPDM gaskets and hand wheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of ultraviolet disinfection units with stainless-steel bodies. Maximum working pressure 16.0 bar. Cold water use only.
'Celcon M90DW CF2001 Natural'. Natual (appears white), injection moulded POM material. For use with water up to 85°C.
'Ronfalin ABS 609 White 2097P'. White coloured (opaque), injection moulded ABS materials. For use with water up to 85°C.
Page 64 of 83
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.