'CVE78'. Black coloured, extruded EPDM material. Shore hardness 80. Tested in-radius size 10.0mm. For use with water up to 23°C.
'H600042'. Black coloured, compression moulded EPDM material. Shore hardness 70. Tested in-radius size 1.3mm. For use with water up to 65°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (brushed stainless steel). The flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. The products are supplied with plastic backnuts and a stainless steel braided PEX lined flexible hose assembly for installation between the tap and the solenoid valve. The HK-Cha models added September are also supplied with a plastic flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single check valve assemblies with DZR brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single check valve assemblies with DZR brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with either a single lever or dome type operating member (see model). The spout outlet incorporates a plastic aerator (specific models only - see model section). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headwork with a single lever, cross top or dome type operating member. The spout outlets incorporate either a plastic flow straightener or aerator supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (brass body, various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with various operating members (see models). The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate either a plastic flow straightener or plastic aerator. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of shower handsets incorporating chromium plated plastic or chromium plated brass bodies (see model). Inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall mounted thermostatic shower valve (brass body, matt black finish), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C
Wall mounted thermostatic shower valve (brass body, matt black finish), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with cube type operating member. Temperature is controlled independently via a thermostatic cartridge with a cube type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Range of gate valves with brass bodies, brass wedges and PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. To be used with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of gate valves incorporating ductile iron epoxy coted bodies and with EPDM ‘O’-ring seals and discs. The valves are operated via a non-rising spindle with a hand wheel operating member Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
`RVK JDP01`. Factory applied, blue coloured epoxy coating. Apply and cure as per manufacturer's technical information document reference 'RVK-PRD-DI-002, issue #1' dated 2017. For use with water up to 85°C.
'DiChem Tiestop'. Site applied, grey coloured cementitious repair mortar. Mix 'DiChem Tiestop' and water in a mass ratio of 9.4:1 and apply as per manufacturer's instructions 'Rev 4, 02.22'. Cure for 21 days@7°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Tiefill'. Site applied, grey coloured cementitious repair mortar. Mix Tiefill with water in a weight ratio of 9.4:1 and apply in accordance with manufacturer’s instructions for use 'bulletin no. TFILL/031/003, issued 'July 2020'. Cure for 21 days@7°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Side entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of floor mounted, single hole, single outlet (fixed), combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout has a waterfall outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: FGH Three phase models 85°C, FGH Single phase models 55.0°C
Range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of stainless steel, PVC and nylon braided shower hoses (various finishes), incorporating PVC, EPDM or PEX liners and various end connections.
Range of wall mounted, concealed, manual blending valves with a brass body incorporating a ceramic cartridge headwork with a single lever operating member. The QS3200 model also incorporates a manual diverter with a single lever operating member. The QS3400 model is a stainless steel bodied spout conector to be used in conjunction with the QS3100 and QS3200 concealed valves. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pressfit connection spherical valves incorporating DZR brass bodies, PTFE seat and packing, NBR ‘O’-rings and various operating members: lever, lever lockable, T-handle and butterfly. For use with copper pipe (manufactured to BS EN 1057), stainless steel pipe (manufactured to BS EN 10312) and carbon steel pipe (ISO 4200 Groupe 1 Series 3). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
'Pearlbond PUP SF2K Primer and DuraPearl HP 500 PW Coating'. Factory applied, grey coloured (once mixed), two-component primer (non-water contact primer) and two-component coating (water contact coating). Mix and apply 'Pearlbond PUP SF2K Primer’ as per Product Data Sheet '2023-02-27'. Cure for 2 hours@25°C. Then mix and apply ‘DuraPearl HP 500 PW Coating' as per Product Data Sheet ‘210705’. Cure for 1 minute@25°C. For use with water up to 85°C.
'Mega Fix IT PW'. Site applied, grey coloured (once mixed), two-component epoxy putty. Mix Part A (white coloured putty) with Part B (cream coloured putty) in a 1:1 mass ratio and apply as per manufacturer's label instructions ‘00000765 Mega Fix-IT PW (MULTI Product Label) v3u.indd 16/05/19’. Cure for 24 hours@20°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'TUSIL® ACQUA HT & TUSIL® ACQUA'. Multi-layered hoses comprising of a white coloured, silicone rubber inner layer, white coloured silicone rubber/polyester middle layer and blue coloured outer layer. The hose is made by vulcanisation on rigid mandrel. For use with water up to 85°C.
'Barco PX+'. Off-white coloured, PTFE paste intended for use as a thread sealant. For use with water up to 23°C.
Range of expansion vessels with stainless steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range on inline filter cartridges incorporating plastic bodies. The filter media varies between models and includes active carbon, silver impregnated active carbon, silver carbon block & weak/strong cationic resin. Maximum working pressure 6.0 bar. Cold water use only.
Range of copper press fittings with EPDM seals for use with EN1057 copper tube. The joints are achieved by means of a press tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of overhead shower outlets (chrome plated plastic bodies). Inlets incorporate a strainer. Maximum operating temperature 85°C
Shower handset with plastic bodies (chrome plated). Maximum operating temperature 65°C.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
'Hurricane' range of Indirect and direct unvented storage cylinders consisting of factory fitted single or twin coil circuit with either a primary or solar coil. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures: Secondary circuit 3.0 bar, Primary Circuit 3.0 bar & Solar circuit 5.5 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic shower panels. Incorporates a single sequential headwork which controls the flow and temperature using a single lever operating member to a fixed riser rail shower hose and handset. The inlet incorporate single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with stainless steel strainers, flow restrictors and isolation valves. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic mixing vales with brass bodies and chrome plated trim sets, incorporating one or two quarter turn ceramic disc headworks with Single Lever operating members. Temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, bar type, thermostatic shower blending valves (chromium plated brass), incorporating a ¼ turn ceramic disc headwork controlling the flow with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 41 of 71
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.