Joule Hot Water Systems UK Ltd Approvals


#2211041

Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2211041
Expiry date:
30/11/2027
Size:
22mm Compression on all circuits
Marking:
EVOCyle logo, max pressure, max temp, capacity and other technical information on label on body.
Installation Requirements:
R001 R140 R360
Model:
TTAMVD-0150LFB ThermaQ Evocyl Air 150 Direct TTAMVD-0180LFC ThermaQ Evocyl Air 180 Direct TTAMVD-0210LFC ThermaQ Evocyl Air 210 Direct TTAMVD-0250LFC ThermaQ Evocyl Air 250 Direct TTAMVD-0300LFC ThermaQ Evocyl Air 300 Direct TTAMVI-0150LFB ThermaQ Evocyl Air 150 Indirect TTAMVI-0180LFC ThermaQ Evocyl Air 180 Indirect TTAMVI-0210LFC ThermaQ Evocyl Air 210 Indirect TTAMVI-0250LFC ThermaQ Evocyl Air 250 Indirect TTAMVI-0300LFC ThermaQ Evocyl Air 300 Indirect
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#2303040

Range of indirect unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 6.0 bar Secondary: 5.5 bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2303040
Expiry date:
31/03/2028
Size:
Primary: 22mm Compression Secondary: 22mm compression
Marking:
Joule, Model name, capacity, max pressures, max temps and other technical information on label on body
Installation Requirements:
R001 R140 R360
Model:
TUMA-00150-LFC TUMA-00180-LFC TUMA-00210-LFC
Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.