'CHEMILINE AH001 FB 026'. Black coloured, niltrile rubber material manufactured by calendaring and curing. Shore hardness 70A. Tested in-radius size 1.1mm. For use with water up to 65°C.
'LSR2650, LSR2660 & LSR2670'. Black coloured, injection moulded liquid silicone rubber materials. Shore hardness between 50 & 70. Tested in-radius size 1.0mm. For use with water up to 65°C.
'FIX 247 (product code 070323)'. Off-white coloured, PTFE paste intended for use as a thread sealant. For use with water up to 23°C.
'Hinton Equipment (product code JJC250)'. Off-white coloured, PTFE paste intended for use as a thread sealant. For use with water up to 23°C.
'TGL Blue Jointing Compound'. Off-white coloured, PTFE paste intended for use as a thread sealant. For use with water up to 23°C.
'Interfix Colle Gel PVC'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Würth Adhesivo PVC Tixpro'. Translucent, colourless (un-pigmented) solvent cement. Apply as per manufacturer's instructions. Cure for 24 hours at 23°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Bidet seat assembly with the flow controlled by a sensor actuated solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 1.75 bar. Maximum operating temperature 45°C.
'QPLAST Pressure Pipe'. Dark grey coloured, extruded PVC pipe. For use with water up to 23°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (brushed stainless steel). The flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. The products are supplied with plastic backnuts and a stainless steel braided PEX lined flexible hose assembly for installation between the tap and the solenoid valve. The HK-Rib model is supplied with a plastic flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (brushed stainless steel). The flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. The products are supplied with plastic backnuts and a stainless steel braided PEX lined flexible hose assembly for installation between the tap and the solenoid valve. The HK-Cha models added September are also supplied with a plastic flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks with either a single lever, cross top or dome type operating member (see model). The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a waterfall type with or without a stainless-steel mesh (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a ceramic cartridge headwork and single lever operating members however model 4E6004 – is fitted with a non rising spindle headwork and dome type operating members. The spout outlet incorporates a plastic flow straightener on models: 4E6002, 4E6003, 4E6004 or flow straightener and aerator kit on models: 4E6011, 4E6012 & 4E6013, and some models are supplied with a click waste. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks with cross top operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headworks. The inlet hose assemblies incorporate a servicing valve and is supplied with a single check valve assembly verified by test (suitable for backflow protection against Fluid Category 2). The spout outlets incorporate a plastic aerator. Maximum working pressure 10.00 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks with single lever Operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The4E6008 and 4E6017 models are also supplied with an optional plastic aerator. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass compression fittings incorporating brass ring olive to be used with pipe manufactured to EN ISO 15875. Maximum working pressure 8.0 bar. Maximum operating temperature 90°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of compact wall outlet assemblies with plastic bodies (chromium plated) and EPDM ‘O’-rings. Maximum working pressure 5.0 bar. Maximum operating temperature 55°C.
Y type fittings incorporating brass body and NBR washer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
Shower kit comprising of a brass bodied wall outlet elbow (chrome plated), TPE lined shower hose (chrome finish) and a brass bodied (chrome plated) shower handset with silicone nozzles. The wall outlet incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps incorporating brass bodies (chrome plated), and quarter turn ceramic disc headowks. The spout outlet incorporates a flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Pillar tap (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating member and plastic back nuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Range of self-closing combination taps with brass bodies (chrome plated), incorporating a non-concussive headwork with dome type operating members. The inlet incorporate an approved single check valve cartridge, however the complete assembly has not been verified to demonstrate it provides backflow protection. The inlets incorporate a servicing valve and stainless-steel filter. The outlet incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.

Self-closing tap with a stainless-steel riser and chromium plated brass outlet incorporating a lever operated non-concussive headwork. The product is supplied with an optional grey plastic ½” BSP (F) x ¼” pushfit inlet adaptor for use with John Guest ‘Super Speedfit’ LLDPE tubing, (not supplied). The product is supplied with metal back nuts. Maximum working pressure 8.0 bar. Maximum working temperature 65°C.
Page 31 of 64
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.