FLOMASTA range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of system 2000 of flange adaptors and connectors with ductile iron bodies (Blue Epoxy Coated) incorporating EPDM seals. For use with PE pipe manufactured to En 12201 & PVC Pipe manufactured to DIN 8062. Maximum working pressure: 16.0Bar Cold water use only.
Range of copper or stainless-steel brazed heat exchangers available with various number of plates as listed below. Maximum working pressure 25.0 Bar (copper brazed models). Maximum working pressure 10.0 Bar (stainless steel brazed models). Maximum operating temperature 100.0°C.
Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C
Range of IUW ultrasonic water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature: 50°C.
Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold and pumps. Maximum working pressure 10 bar. Cold water use only.
‘AMV-FB’ and ‘AMV-FE’ range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold, vertical multistage pumps, expansion vessel, isolation valves, pressure sensor and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
EASO range of shower head and hand showers, with ABS bodies and chromium plated finish. Open outlet use. Maximum operating temperature - 65 °C.
Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of overhead shower outlets with Various finishes. The inlets incorporate a stainless-steel strainer and flow regulator. Models 64400250CH, 67400250BBL, 63400250BBR, 68400250MB & 61400250BRZ Incorporates a shower arm.
Non-metallic materials and components comply with BS6920 at 60°C
Range of pillar taps with (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of self-closing, water fountain taps, (chrome plated brass bodies). Model 311QU1 has a stainless-steel spout. Model 312QU1 incorporates a stainless-steel filter on the outlet. Products are supplied with metal backnuts. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 85°C.
Range of self-closing basin taps (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlets incorporate a plastic aerator, and the products are supplied with metal backnuts. Maximum operating pressure 7 Bar Maximum operating temperature 55 °C
Range of stainless-steel or nylon braided hoses with a PEX inner hose. The hoses are either supplied with silicone or EPDM 'O'-rings. Some hoses incorporate a isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel or nylon braided hoses with a PEX inner hose. The hoses are supplied with either silicone or EPDM 'O'-rings. Some hoses incorporate a isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Stainless steel interlocked (chrome plated) silicone lined kitchen tap pull-out hose. Open outlet use only. Maximum operating temperature 85°C.
Range of EPDM hoses with either nylon or stainless-steel braiding, with or without a PVC sheath. Some models incorporate isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of elastomeric shower hoses with EPDM lining and ‘O’-rings. The product incorporates a flow restrictor. Maximum operating temperature 60.0°C Open outlet use only
Range of stainless-steel braided flexible hose assemblies incorporating EPDM inner and plastic (BFSFH12-EE80/150) or brass (BFSFH19-EE60) captive nut end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection). Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of Compress 5800i AW vertical cased and insulated indirect unvented stainless steel hot water storage cylinders fitted with a Caleffi 309508 CST temperature and pressure relief valve set at 10 bar & 90°C, and supplied with a Caleffi inlet control group consisting of in-line pressure reducing valve (set at 3.5 bar) and pressure relief valve (set at 6 bar) and incorporates an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2). The cyclinders also supplied with an 18L expansion vessel and Intatec filling loop assembley (FL12041510). Maximum working pressure 10 bar. Maximum operating temperature 80°C.
Range of manually operated flow control valves with (brass bodies - various finishes), incorporating either a non-rising spindle headwork or (quarter turn ceramic disc headwork model 16 973 180 only) with cross top, lever or dome type operating members. Maximum working pressure; 10Bar Maximum operating temperature 70°C
Range of wall mounted, manually blended, shower valves, (brass bodies – various finishes). Incorporating a ceramic cartridge controlling both the flow and temperature. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating quarter turn ceramic disc headwork and a two-way, half-turn ceramic disc manual diverter for dual outlet models. The inlets incorporate a stainless-steel strainer & an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of T-type thermostatic blending valves with nickel plated brass bodies and EPDM ‘O’-rings. The inlet and outlet incorporate an approved check valve cartridge ((verified by test - suitable for backflow protection against fluid category 2). Models with compression ends are to be used with copper pipe EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of concealed, wall mounted thermostatic blending valves with brass bodies (chromium plated trim sets). The products consist of a two-way diverter and a thermostatic cartridge controlling the temperature. All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of concealed wall mounted thermostatic shower valves, (brass bodies – various finishes & strim sets). Incorporating either a ceramic disc headwork, two-way diverter or both (see models). The temperature is controlled independently via a thermostatic cartridge. The valves incorporate approved single check valve cartridges, however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 44.0°C
Range of concealed thermostatic shower mixers (brass bodies - various finishes). The flow is controlled by a four-way manual diverter (3 on, 1 off positions) with single lever, cube type or dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with single lever, cube type, dome type or cross top operating members. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, thermostatic, shower mixers, (brass bodies - various finishes) incorporating a two-way ceramic disc diverter headwork to control the flow between two shower outlets with dome type operating members. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with a dome type operating member. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Combined temperature and pressure relief valves pre-set at 7.0 bar with a DZR brass body. Maximum operating temperature 90°C.
Range of regulating and shut-off valves with brass bodies and EPDM ‘O’-Rings. Maximum working pressure 16.0 Bar for BSP (M) and 25.0 bar for BSP (F). Maximum operating temperature 85.0°C
Range of spring-loaded non-return valves with stainless steel bodies. Maximum working pressure 24.5 bar. Maximum operating temperature 85°C
Range of adjustable, in-line pressure reducing valves with blue epoxy coated, cast iron bodies. SP models: maximum supply pressure 25.0 bar, outlet pressure range 1.5 to 7.0 bar. HP models: maximum supply pressure 25.0 bar, outlet pressure range 3.0 to 12.0 bar. LP models: maximum supply pressure 8.0 bar, outlet pressure range 0.5 to 3.0 bar. Maximum operating temperature 60°C.
Range of spherical valves with DZR brass bodies and brass ball. For use with copper pipe manufactured to EN1057. Maximum working pressure 25.0 Bar Maximum operating temperature 85.0°C
Range of spherical valves with nickel plated brass bodies, incorporating a chrome plated brass ball, PTFE seats with either lever, butterfly or T operating members. Maximum working pressure 20.0 bar. Maximum operating temperature 85˚C
Range of lever or butterfly operated spherical valves with brushed chromium plated brass bodies, chromium plated brass ball and PTFE seat. Maximum working pressure model K656: ¼” to ½” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Model K6566 model: ¼” to ⅜” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Models K8912 , K8913 & K6568 models: ¼” to ⅜” = 64.0 bar. Maximum operating temperature 99°C.
Range of spherical valves with either brass (UW24905 & UW24907 models) or nickel plated (UW24809, UW24906, UW24933, UW24908 & UW24934 models) brass bodies with chrome plated brass ball and operated via lever, butterfly type handle or screwdriver slot. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves incorporating nickel plated brass bodies with chrome plated brass ball and operated via lever, butterfly type handle or screwdriver slot. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
STAD range of balancing valves with brass bodies, PTFE sliding washer and EPDM O-rings. Models are available with or without a drain port. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of regulating valves with blue epoxy coated ductile iron bodies incorporating EPDM gaskets and hand wheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of in-line water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of ultraviolet disinfection units with stainless-steel bodies. Maximum working pressure 16.0 bar. Cold water use only.
Range of UV disinfection units with stainless steel bodies and EPDM seals. The UV lamps are housed inside quartz tubes. Maximum working pressure 10.3 bar. Maximum operating temperature 40°C.
'PRIMGREEN® ENDURANCE & Primgreen LAT 12035' primers for use with 'RILSAN® PA11 T BLUE 7444 MAC (16293), PA11 T GREY 5161 MAC (17203), PA11 T WHITE 1488 AC (17219) & PA11 T BLACK 7450 AC (17185)' coatings. Factory applied primers and powder coatings. The piece to be coated is to be pre-heated to 330°C for 10 minutes, the primer and coating applied in accordance with user instructions 'Dircom - 4418E/05.2015/20' and then cured for 10 minutes@330°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 30 of 50
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.