‘SharkBite’ range of brass push fit fittings incorporating an EPDM ‘O’-ring. For use with the following pipes: JG Speedfit Layflat Polybutylene Barrier Pipe (JG BPB pipe manufactured to BS EN 7291-2:2010), 'BPEX' Barrier Pipe (JG BPEX pipe manufactured to BS EN 7291-3:2010), Polybutylene barrier pipe (manufactured to BS EN 7291-2:2010), PEX barrier pipe (manufactured to BS EN 7291-3:2010) and Copper pipe (manufactured to BS EN1057:2006). Maximum working pressures and operating temperatures: When used with Polybutylene barrier pipes (manufactured to BS EN 7291-2:2010) and PEX barrier pipes (manufactured to BS EN 7291-3:2010): 12.5 bar, cold water use only. 6.0 bar @ 95°C. When used with copper pipe (manufactured to BS EN1057:2006): 10mm sizes: Maximum working pressure 16.0 bar. Cold water use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. 15-22mm sizes: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C. 28mm size added April 2024: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of WC flush valves with an ABS body and silicon seal. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal adjustable height overflow. Cold water use only.
Single flush WC outlet valves with an ABS plastic body (TSL721 WC99-016) operated via a mains powered infra red sensor assembly TSL721 (WC99-016A). Cold water use only.
Range of copper brazed, stainless steel heat exchangers available with between 4 & 70 plates. Maximum working pressure 50 bar. Maximum operating temperature 100°C
Range of plate heat exchangers with pressed stainless steel plate bodies and copper brazing. Available with threaded or flat face seal connection (see model). Maximum working pressure varies by model: ZT190 & ZT207 - 8.0 bar; ZB190, ZB195, ZB200, ZB207 & ZB315 - 10.0 bar; ZC315 (flat face seal version only) - 16.0 bar; ZC190, ZC207, ZC315 (threaded only) & Z(B-C-E) 250, 400, 450, 500 – 30.0 bar or 45.0 bar (models with additional upper and lower plates only); ZB600 & ZB700 - 30.0 bar. Maximum operating temperature 99°C.
Wall mounted electric instantaneous water heater. The inlet incorporates a plastic flow sensor with strainer. Maximum working pressure 6.0 Bar Maximum operating temperature 55.0°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C
Water meter manifold assembly with gunmetal body, incorporating a servicing valve and a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Max operating pressure 16 bar Maximum operating temperature Cold water only
Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall & floor mounted, two hole, single outlet combination tap assemblies with brass bodies incorporating ceramic cartridge headworks with single lever operating members. Spout incorporates a plastic aerator. Products also incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of flow sensors with plastic bodies and rotors. Maximum working pressure: 10 Bar. Maximum operating temperature: 80°C.
Range of EEICo brass threaded fittings. Maximum working pressure 20.0 bar. Maximum operating temperature 60°C.
Range of stainless steel bodied mechanical pump shaft seals. The 491 model comprises of carbon and silicone carbide seal faces and EPDM ‘O’-rings. The 1510 model comprises of carbon and silicone carbide seal faces, EPDM ‘O’-rings and an orange NBR/aramid fibre gasket. Maximum operating temperature 100°C.
‘SCALA 2’ integrated, self-priming, plastic bodied (compact) mains pressure boosting pump. Maximum working pressure 10.0 bar. Cold water use only.
`UPM3` range of single stage circulator pumps, with stainless steel or plastic bodies, plastic impellers, ceramic shafts and bearings, EPDM 'O'-rings and seals. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of shower handset with chrome plated or white plastic bodies. Colour coding discs are located on the face plates of specific models. Maximum operating temperature 60°C
Range of shower handsets with either a white or chrome plated plastic body. Maximum operating temperature 45°C.
Range of overhead shower outlets with chromium plated plastic bodies. The inlets incorporate combined EPDM washers and stainless-steel strainers. Maximum working pressure: open outlet use only Maximum operating temperature 60°C
Range of shower arms and ceiling connectors (brass bodies – various finishes) & overhead shower outlets (plastic bodies - various finishes), incorporating EPDM O rings, plastic flow regulators and stainless-steel strainers. Open outlet use only Maximum operating temperature 60.0°C
Range of shower arms and ceiling connectors (brass bodies – various finishes) & overhead shower outlets (plastic bodies - various finishes), incorporating EPDM O rings, plastic flow regulators and stainless-steel strainers. Open outlet use only. Maximum operating temperature 60.0°C
Range of shower riser kits and shower cradle kits. Models PSA006, PSA013, PSA007, PSA012, PSA002, PSA004, also incorporate a manual operated diverter with single lever operating member. Maximum operating temperature 65.0°C
Hand shower outlet with plastic bodies (various finishes, see models) incorporating a PSF membrane filter and EPDM O-rings. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature: 50°C.
Range of shower outlets comprising of shower handsets (brass bodies – various finishes) and overhead showers (stainless-steel bodies – various finishes), incorporating stainless-steel strainer washer. Model (CPH05013) incorporates a flow limiter in the inlet. Maximum operating temperature 85°C.
Range of shower handsets with chromium plated ABS bodies. Some models incorporate multi-spray patterns. Maximum operating temperature 60 °C.
Range of shower handsets, plastic bodies. Maximum operating temperature 70 °C.
Range of in-line `Y` patterned strainers with brass bodies and stainless steel filters. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Wall mounted bib tap (chrome plated brass), incorporating a non-rising spindle headwork with a cross top operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
Range of drain taps with brass or DZR brass body (some models chrome plated) and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose untion taps with chrome plated brass body and spindle headwork with dome type operating member. Maximum operating pressure 10.0 bar. Cold water use only.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 65°C.
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar, Maximum operating temperature 65°C.
Range of nylon or stainless steel braided flexible hose assemblies incorporating a PE-X inner hose, EPDM ‘O’-rings and/or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of PVC lined shower hoses with silicone rubber gaskets and interlocked chromium plated outer coating. For open outlet use only. Maximum operating temperature 65°C.
Stainless steel interlocked shower hose with PVC inner hose and EPDM O-rings, various finishes. Open outlet use only. Maximum operating temperature 65°C.
Range of stainless steel braided, EPDM lined flexible hose assemblies. Models are available with a variety of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and an approved check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 3.0 Bar Secondary: 5.5 Bar Solar: 3.0 bar Maximum operating temperature 90.0°C
Range of wall mounted, concealed, bath-shower mixer valves (brass bodies, chromium plated trim sets) incorporating a ceramic cartridge headwork with single lever operating members and a manual diverter to two outlets. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of wall mounted, concealed, thermostatic blending valves with brass bodies in various finishes. The flow is controlled via ceramic disc or push-button headwork with dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, thermostatic blending valves, (brass bodies various finishes), incorporating a quarter turn ceramic disc headwork controlling the flow.Temperature is controlled independently via a thermostatic cartridge with a manual override button incorporating dome or lever type operating members, Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic bar shower mixer,(brass bodies - various finishes), incorporating quarter turn ceramic disc headworks. The temperature is controlled independently via a thermostatic cartridge that incorporates a manual override button. Model (CPH8072AB) incorporates a ceramic disc diverter valve. Incorporating dome or cube operating members. The inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves incorporating detent headworks controlling the flow. Temperature is controlled via a thermostatic cartridge incorporating a manual override button. Both inlets incorporate approved single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). The products are supplied with a shower hose, shower handset and over head shower. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of concealed, wall mounted thermostatic blending valves, (brass bodies – various finished trim sets). Models (CPHCA22-CONC & CPHCON-3) incorporate a ceramic disc diverter valve. Model (CPHCON-1) incorporates a quarter turn ceramic dsic headwork. The temperature is controlled independently via a thermostatic cartridge. All models are operated using single lever operating members. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Wall mounted, thermostatic shower valve, (brass body – chrome plated), incorporating a single sequential headwork with a single lever operating member. The inlet elbows incorporate key operated spherical valves with chrome plated brass balls, PTFE seats and approved single check vlave cartridges, however, the complete product has not been fully tested to demonstrate backflow protection. To be used with copper pipe only – Standard EN 1057 Maximum working pressure 5 Bar. Maximum operating temperature 65°C
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies), incorporating a quarter turn ceramic disc headwork controlling the flow with cubed or dome type operating members. The temperature is controlled independently via a thermostatic cartridge with dome or cubed type operating members that incorporate manual override buttons. The inlets incorporates approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). Products are supplied with a shower handset, shower hose, overhead shower and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower valves (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature with a single lever operating member. The products are supplied with 15mm compression inlet elbows incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets also incorporate plastic flow regulators. The 90033CP model can have either a top or bottom outlet, which is achieved by re-positioning the blanking plug and threaded outlet. The compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of doubled flanged butterfly valves with blue epoxy coated ductile iron bodies and discs, incorporating EPDM seals. Maximum working pressures 25.0 bar. Maximum operating temperature 85°C.
Range of handwheel operated butterfly valves with blue epoxy coated ductile iron bodies and EPDM rubber seat. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Range of butterfly valves with blue epoxy coated ductile iron bodies and discs, and EPDM seals with a wheel type operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
2-way ceramic disc diverter incorporating a brass body, EPDM ‘O’-rings and a silicone gasket. Maximum operating temperature 85°C.
Range of manually operated plunger valves with blue epoxy coated ductile iron bodies and EPDM seals. The flow is controlled via a handwheel. Maximum working pressure 25.0 Bar. Maximum operating temperature 85°C.
Page 159 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.