‘Showermate Universal’ range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.
Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of cold water in tank booster sets incorporating an ‘AB’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of shower outlets: swivel ball joint overhead shower heads with brass bodies (chromium plated) and shower handsets with plastic bodies (chromium plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of overhead shower outlets with brass bodies in various finishes (See models) incorporating EPDM ‘O’-rings and seals. The inlet to the shower heads incorporate either a plastic steel sieve (26 031 xxx) or a stainless steel (26 032 xxx) has a stainless-steel sieve. The inlet for the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection (Model 26 031 xxx only). Maximum operating temperature 60°C.
Range of plastic shower handsets (various finishes). Maximum operating temperature 75°C.
Range of overhead shower outlets with stainless steel bodies (various finishes). The inlet incorporates a stainless steel filter and a plastic flow regulator. Maximum working temperature 60°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of shower kits, comprosing of shower handset, shower hose, riser rail and overhead shower outlet depending on kit. Inlets incorporate a flow regulator (models 1.1740.578 & 1740.155) Maximum operating temperature 60°C.
Range of overhead showers with brass and plastic bodies (various finishes - see models). The inlet incorporates a stainless-steel strainer and a plastic strainer. Products to be used with basic sets with brass bodies and EPDM O-rings. Open outlet use only
Non-metallic materials and components comply with BS6920 at 60°C
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower rose outlets (plastic body with various finishes). The inlet incorporates a stainless-steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Range of flow switches incorporating brass or stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of flow sensors with brass or plastic bodies. Flow sensor type series VTY10 (plastic body, G3/4): Maximum working pressure 10.0 bar. Maximum operating temperature 85°C. Flow sensor type series VTY10 (plastic body, Quickfasten OD 22.5mm): Maximum working pressure 10.0 bar. Maximum operating temperature 70°C. Flow sensor type series VTY10 (brass body, G1/2): Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Turbine flow sensors with a plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Pillar tap (chromium plated brass) , incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a stainless steel aerator and the product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing combination taps with brass bodies (chrome plated), incorporating a non-concussive headwork with dome type operating members. The inlets incorporate an approved single check valve cartridge, however the complete assembly has not been verified to demonstrate it provides backflow protection. The inlets of model 28681 incorporate a stainless-steel filter. The inlets of model 28682 incorporate a servicing valve and stainless-steel filter. The outlets of all models incorporate a plastic flow straightener. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
PEX lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
EPDM lined flexible hose assemblies with either nylon or stainless-steel braiding and a variety of end connectors. Some models are supplied with screwdriver operated isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of multi-layered flexible hoses (TPE inner liner/PVC middle/PVC outer with polyester braiding in-between) and stainless-steel braided EPDM flexible hoses. The hoses are supplied with a variety of end connections incorporating brass barbed hose inserts or white plastic barbed hose inserts. The hoses may also incorporate a servicing valve (see model). The push fit connectors are to be used with copper pipe (Manufactured to EN1057), PB pipe (Manufactured to BS EN21003) & PE-x pipe (manufactured to BS EN7291-3). Products shown with a “P” suffix (eg. WFLX15P, FLX43P) are a prepacked variant of the original product eg. WFLX15, FLX43. Products shown with a “SB” suffix (eg. FLX15P-SB, WFLX28-SB) are a reduced box quantity of an existing product. Maximum working pressure and operating temperature: 12.0 bar @ 20°C and 6.0 bar @ 65°C.
Range of free standing direct gas fired unvented cyliners with a enamel coating internal lining and magnesium sacrificial anode. Fitted with a combined temperature and pressure relief valve set at 7 bar. Maximum working pressure 6.5 bar. Maximum operating temperature 80°C.
Range of two, three, four and five-way manifold assemblies incorporating brass bodies (brushed chrome finish) and EPDM ‘O’-rings. The products are supplied with isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of concealed, wall mounted, electronically controlled blending valves (brass body). The flow is controlled via a solenoid valve actuated via an infra-red sensor. Inlets to the sensor box incorporate stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Wall mounted, manually operated, concealed blending valves with cast brass bodies with chromium plated faceplates, incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted bar type thermostatic shower valve, with a ceramic cartridge headwork controlling the flow between overhead shower and handset with a dome type operating member incorporating a manual override button. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a strainer and a single check valve cartridge, however, the complete assembly has not been tested to demonstrate it provides backflow protection. Supplied with hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of two detent headworks (push to on, push to off) as the main flow control for each shower outlet, a ¼ turn ceramic disc valve with a dome type operating member controlling the flow volume, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. These assemblies are to be inserted into the concealed body. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed, thermostatic shower blending valves, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of a quarter turn ceramic disc headwork, or a 2 or 3 way ceramic disc diverter headwork (see model) with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) functional trim set. The functional trim set comprises of a 2 way ceramic disc diverter headwork with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The functional trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Thermostatic blending valve (chromium plated brass), the valve body inlets incorporate single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with stainless steel strainers and inlet connections that incorporate screw driver operated spherical valves. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and trim sets (chrome plated). Incorporating a thermostatic cartridge headwork with cubed or dome type operating members. The inlets incorporate a flow regulator and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic blending valves with brass bodies (chrome plated), incorporating a manual diverter to two outlets with an off position (model XB-AZ-037A), two ceramic disc headworks controlling the flow to both outlets (model XB-AZ-035A) or one outlet controlled via a ceramic disc headwork (model XB-AZ-034A). The temperature is controlled via a thermostatic cartridge with various operating members (see models). Inlets incorporate stainless-steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted thermostatic shower blending valves incorporating brass bodies and an external trim set (various finishes). Flow is controlled to each shower outlet via individual ‘detent’ (push to on push to off) headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose, shower handset, riser rail and overhead shower outlet. The product is also supplied with two loose plastic flow regulators for installation between the valve and the shower hose, as well as on the inlet to the overhead shower. Maximum working pressure 5.0 bar. Maximum operating temperatures: shower handset 50°C, all other items 65°C.
Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). The A47203VUK model uses two ‘detent’ (push to on push to off) headworks to control the flow to each outlet. Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer or stainless steel strainer (A47203VUK model) and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.

Range of combined temperature and pressure relief valves incorporating DZR brass bodies, EPDM ‘O’-rings and silicone seat washers. The vales are pre-set at 4.0, 6.0, 7.0 or 10.0 bar (see model). The valves incorporate a manually operated rotational easing gear. Maximum operating pressure 10.0 bar. Maximum operating temperature 90°C.
Range of piston type float operated inlet valves with brass bodies. The valves discharge from a downwards atmospheric discharge arrangement on the underside of the body. Maximum working pressure: 3.0 (1FVA106 & 1FVA104 models only) or 14.0 Bar (all other models) Cold water use only.
Piston type float operated inlet valves with blue epoxy coated ductile iron bodies. The products are supplied with a plastic float and carbon steel (galvanised) lever. The valves discharges from a downwards atmospheric discharge arrangement on the underside of the body. Maximum working pressure 16.0 bar. Cold water use only.
Monobloc assembly with a DZR brass body comprising of a stainless steel strainer, adjustable pressure reducing valve and two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose pressure gauges. For use with copper pipe (manufactured to EN1057). The product is also supplied with Maximum inlet supply pressure 6.0 bar. Maximum outlet pressure 0.8 bar to 6.0 bar. Maximum operating temperature 35°C.
Range of adjustable, bronze in-line pressure reducing valves. Model 753A ½”, ¾” & 1” sizes and model 754A 1¼” size have inspection ports on the outlet only. Model 754A 2” and 4” sizes have inspection ports on the inlet and outlet. The valves incorporate a stainless-steel strainer. Maximum inlet supply pressure 20.0 bar. Maximum outlet pressure 1.0 bar to 4.0 bar. Maximum operating temperature 70°C.
Range of pre-set, spring loaded, angled pressure relief valves, with a plastic body and EPDM diaphragm. The B312021 CST model only is pre-set at 4.0 bar, all other models are pre-set at 3.0 bar. The valves are fitted with either rotary type easing gear or hand operated lifting gear. Maximum operating temperature 99°C.
Range of latching and non-latching solenoid valves with brass bodies and an integral stainless-steel strainer. X262513141 (abc) (dd) models have a NBR ‘O’-Ring and diaphragm, all other models have an EPDM ‘O’-Ring and diaphragm. Maximum working pressure: see model. Maximum operating temperatures: X262513141(abc)(dd) models 65°C, all other models 85°C.
Range of in-line, “T” type or angled spherical valves incorporating brass bodies and brass ball, EPDM ‘O’-rings/Washers, PTFE seats and single lever or butterfly lever operating members. Some models incorporate port or pressure gauge. Models 0516/03DCVR1, 0516/03DCVR2 & 0516/04TR1 incorporate approved check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressures 10.0 bar Maximum operating temperature 100°C.
Range of brass bodied, straight and angled two and three-port spherical valves. Some models incorporate a screw-down pattern drain valve. Products incorporate a chrome-plated brass ball and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves (nickel plated) brass bodies with single lever operating members, (chromium plated) brass ball and PTFE seat. Maximum working pressure 40.0 bar (Models 124-1027 CST, 124-1028 CST and 124-1029 CST) Maximum working pressure 25.0 bar (Models 124-1030 CST and 124-1031 CST) Maximum working pressure 16.0 bar (Models 124-1032 CST and 124-1033 CST) Maximum operating temperature 85°C.
Range of angled isolation ball valves incorporating brushed chrome plated DZR brass bodies, DZR brass ball (chrome plated), stainless steel strainer and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pressfit connection spherical valves incorporating DZR brass bodies, PTFE seat and packing, NBR ‘O’-rings and various operating members: lever, lever lockable, T-handle and butterfly. For use with copper pipe (manufactured to BS EN 1057), stainless steel pipe (manufactured to BS EN 10312) and carbon steel pipe (ISO 4200 Groupe 1 Series 3). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of spherical valves incorporating stainless steel strainers, chrome plated brass ball, housed within DZR brass bodies with a brushed chrome finish. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of straight, angled, tee and Y shaped isolation valves incorporating brass bodies, NBR ‘O’-rings or PTFE seats depending on model variant. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Page 12 of 131
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.