Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Overhead ceiling or wall mounted (depending on shower arm) shower outlet with chrome plated plastic body, EPDM o-rings and a plastic flow restrictor at the ball joint. Maximum working pressure: Open outlet. Maximum operating temperature: 60°C.
Range of overhead shower outlets, (brass bodies - various finishes. The inlets incorporate combined EPDM washers and stainless-steel strainers. Open outlet use only Maximum operating temperature 60°C
Range of wall or ceiling mounted shower outlets (chromium plated brass). All models except SH5010 incorporate a flow regulator. Open outlet use only. Maximum operating temperature 65 °C.
Range of showerheads with a plastic body (various finishes - see model) and brass connections. The A7889, A7890 and A7891 models incorporate two solenoids controlling the flow to the spray plate or a central plastic aerator. The showerhead inlet also incorporates a plastic flow regulator (except for the A7889 models). Open outlet use only. Maximum operating temperature 60.0°C
Range of shower handsets with brass bodies (various finishes). The inlets incorporate a plastic flow regulator and an approved single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C.
EASO range of shower head and hand showers, with ABS bodies and chromium plated finish. Open outlet use. Maximum operating temperature - 65 °C.
Shower handset with plastic body. Maximum operating temperature 85C Open outlet use only
Non-metallic materials and components comply with BS6920 at 70°C
Range of in-line `Y` patterned strainers with brass bodies and stainless steel filters. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Range of `Y` patterned in-line strainers with black epoxy coated cast iron bodies and stainless-steel screens. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Flow sensor with a plastic and brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of wall mounted hose union bib taps incorporating a rising spindle headwork with a T - handle operating member. Model 13.20202.G15.CP5R-8511 has a DZR brass body, all other models have a brass body. Model 13.20252.G15.CP5R-8510 incorporates a lockshield device at the base of the operating stem. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps, (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork with a cross top operating member. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of pillar taps with (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Self-closing, wall mounted bib tap (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlet incorporates a plastic aerator with integral flow regulator or optional flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of TPE shower hoses (various finishes) with EPDM seals. Open outlet use only. Maximum operating temperature 60.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection). Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of Compress 5800i AW vertical cased and insulated indirect unvented stainless steel hot water storage cylinders fitted with a Caleffi 309508 CST temperature and pressure relief valve set at 10 bar & 90°C, and supplied with a Caleffi inlet control group consisting of in-line pressure reducing valve (set at 3.5 bar) and pressure relief valve (set at 6 bar) and incorporates an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2). The cyclinders also supplied with an 18L expansion vessel and Intatec filling loop assembley (FL12041510). Maximum working pressure 10 bar. Maximum operating temperature 80°C.
Range of single/double orifice air venting valves with blue epoxy coated ductile iron bodies, and a stainless-steel float ball. Incorporating EPDM washers. Maximum working pressure 16.0 Bar. Maximum operating temperature 80.0°C.
Range of air venting valves with blue epoxy coated ductile iron bodies and a plastic float. Maximum working pressure16.0 bar. Cold water use only.
Range of manually operated flow control valves with (brass bodies - various finishes), incorporating either a non-rising spindle headwork or (quarter turn ceramic disc headwork model 16 973 180 only) with cross top, lever or dome type operating members. Maximum working pressure; 10Bar Maximum operating temperature 70°C
Range of wall mounted concealed, manual blending valves with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever type operating member. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a single sequential headwork with a single lever operating member. The inlets incorporate a concentric isolation valve, plastic flow regulator & stainless-steel strainer. The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating quarter turn ceramic disc headwork and a two-way, half-turn ceramic disc manual diverter for dual outlet models. The inlets incorporate a stainless-steel strainer & an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of T-Type thermostatic mixing valve (chromium plated brass). For use with copper pipe to BS EN1057. Maximum working pressure; 10 Bar Maximum operating temperature 85°C.
Range of thermostatic blending valve (chromium plated brass). The inlets incorporate stainless steel strainers and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted bar type shower mixing valve (brass body, various finishes - see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The hose outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of concealed, wall mounted thermostatic blending valves with brass bodies (chromium plated trim sets). The products consist of a two-way diverter and a thermostatic cartridge controlling the temperature. All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 90°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 100°C.
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies), incorporating ceramic disc diverter valve controlling the flow with a cubed type operating member. The temperature is controlled independently via a thermostatic cartridge with a cubed type operating member that incorporates a manual override button. The inlets incorporate stainless-steel strainer washers and approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). Products are supplied with shower handset, shower hose, overhead shower and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Ranges of wafer or lugged butterfly valves with blue epoxy coated ductile iron bodies incorporating EPDM seat. The valves can be supplied with either Stainless steel, Nickel or blue epoxy coated ductile iron discs. Maximum working pressure: 16.0bar. Maximum operating temperature: 85°C.
Range of plastic, ceramic disc diverter valves. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Concealed three-way diverter valve with various body finishes and EPDM ‘O’-rings. Also supplied with various trim sets. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of pilot operated flow control valves with (blue or red/brown) epoxy coated stainless steel bodies and EPDM ‘O’-rings. Auxiliary components include stainless steel tube with fittings, a strainer, spherical valves, needle valve and restriction orifice. Maximum working pressure 16.0 Bar Maximum operating temperature 65 °C.

Range of deck mounted flow control valves (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork and a single lever or cross top operating member. Maximum working pressure 5.0 Bar Maximum operating temperature 85.0°C
Range of deck mounted flow control valves which incorporate a quarter-turn ceramic disc headworks with either T shaped, cross top, single lever or dome type operating members. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of eccentric plug valves with blue epoxy coated ductile iron bodies, PTFE washers a stainless steel plug which is fully encapsulated with EPDM. Maximum working pressure 16 Bar. Maximum operating temperature 80°C.
Range of swing gate, non-return valves with (blue, black or red epoxy powder coated) ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non-return, swing gate valves with bronze, DZR brass or brass bodies and DZR brass, bronze or brass discs. Maximum working pressure 20.0 bar or 16.0 bar (please refer to model) Maximum operating temperature 85°C.
533 series of in-line, manually adjustable pressure reducing valves (DZR brass or brushed chrome plated DZR brass bodies) incorporating a stainless-steel strainer. All models except 533159 are supplied with a pressure gauge. Models with compression connection are for use with copper tube (manufactured to BS EN 1057). Maximum supply pressure 16.0 bar. Outlet pressures between 1.0 – 6.0 bar. Maximum operating temperature 40°C.
Range of adjustable pressure reducing valves with stainless steel bodies and EPDM ‘O’-rings and diaphragm. These products are available with the following adjustable outlet pressures: between 1.0 and 6.0 bar (model REF-150-S is between 1.2 and 6 bar), between 4.0 and 10.0 bar or between 8.0 and 13.0 bar. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of pilot operated pressure reducing valves with blue epoxy coated ductile iron bodies. The valves have an adjustable pressure reducing facility controlled via a pilot valve (with an operating range of 1 to 6 bar), with auxiliary components including stainless steel tubing, fittings and spherical valves. Maximum working pressure 16.0 bar. Maximum operating temperature 23°C.
Range of spherical valves with DZR brass bodies and brass ball. For use with copper pipe manufactured to EN1057. Maximum working pressure 25.0 Bar Maximum operating temperature 85.0°C
Range of inline spherical ball valves with black plastic bodies and POM (Acetal) seats. Maximum working pressure - 16.0 Bar. Maximum operating temperature - Cold water use only.
Range of gate valves with brass bodies, bonnets and non-rising stems, with hand wheel or lockshield operating members. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Page 109 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.