Range of two-hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating non-rising spindle headworks with dome type operating member and a quarter turn ceramic disc headwork with single lever operating member. The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 6.0 Bar Maximum operating temperature 65.0°C
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with either cross top, dome type or single lever operating members (see model). The products are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator or flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar Maximum operating temperature 65°C.
Two-hole, single outlet, swivel, combination tap assembly with (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The product is supplied with a stainless steel braided PEX lined flexible hose assembly for connection between the control valve and the spout. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of two-hole, metal, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disk headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts, a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C (except CLF106 & PSA106 which is Maximum operating temperature 65°C)
Range of two-hole, metal, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disk headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts, a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two-hole, single outlet (fixed) combination tap assemblies, various finishes incorporating quarter turn ceramic disc headworks with various operating members and lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks, single lever operating members and a manual diverter to shower outlet. Models (HB6001737) incorporate a plastic flow straightener at the spout outlet. Models (HB6013738) incorporates a waterfall outlet. The products are supplied with metal back nuts. Maximum working pressure 3.5 Bar. Maximum operating temperature 60.0°C
Range of deck-mounted 3-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating half turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic aerator. The product uses brass back nuts and stainless steel braided, PEX lined interconnecting hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Three hole, single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating quarter turn ceramic disc headworks with dome type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies, for use between the valves and spout. Also supplied with a lever type pop up waste. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Wall mounted spout outlet with chromium plated brass body, incorporating a plastic flow regulator in the inlet. Open outlet use. Maximum operating temperature: 60°C.
Range of wall mounted spout outlets (brass bodies – various finishes), incorporating a plastic aerator. Open outlet use only. Maximum operating temperature 65°C.
Deck mounted spout outlet with chromium plated brass body. The inlet incorporates a plastic flow regulator, and the spout outlet incorporates a plastic flow straightener with an integral strainer. Maximum working pressure: Open Outlet. Maximum operating temperature 60.0°C.
Wall mounted spout with a brass body (various finishes) and a brass rough kit incorporating a stainless-steel strainer and a plastic flow regulator on the inlet of the spout. Open outlet use only. Maximum operating temperature: 60.0°C (10 942 xx0) and 80.0°C (10 941 180)
Range of stainless-steel braided convoluted hose assemblies and expansion joints with either threaded or flanged end connections. Maximum working pressure: 16bar. Maximum operating temperature: 90oC.
Range of horizontal and vertical expansion vessels with EPDM membrane and stainless-steel connections. Maximum working pressure: 8.0 bar (35 litre model); 10.0 bar (50 litre up to 400 litre models).
Range of inline filter cartridges with plastic or chromium plated brass bodies. Models 02-803231, 02-803235 & 02-803236 incorporate a plastic flow regulator, stainless steel filter and and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides adequate backflow protection. Model 02-000242 is a replacement filter for 02-803236 Chrome In-line filter. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Inoxpres range of stainless-steel crimp fittings with EPDM ‘O’-rings and gasket for use with Inoxpres stainless-steel tube (1.4404 AISI 316L or 1.4521 AISI 444 – annealed or not-annealed). The connection is created by using a pressing tool. For above and below ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 95°C.
Instantor Metric Copper Press Range crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of Cupro- Fit press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
“DZRCOM” range of DZR brass compression fittings for use with copper pipe (manufactured to EN 1057). The tank connectors incorporate a NBR gasket. The straight tap connectors incorporate a blue fibre gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
MecFlow Press (PPSU & Brass) Ranges of press fittings for use with MecFlow Press pipes. Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
"Yi Sin" Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of water meters with (blue epoxy coated) brass bodies and plastic working chamber. The inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of in-line and concentric water meters with composite bodies, TPE gasket and NBR ‘O’-ring(s). The products have an integral plastic filter. The inlet of the in-line models includes a non-return valve. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. The products have an integral plastic filter. The inlet includes a non-return valve. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Octave range of water meters with blue epoxy coated cast iron or plastic bodies (see models). Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C
Range of submersible pressure sensors and hydrostatic transmitters (supplied in lengths up to 1000m). Cold water use only.
Range of concealed, wall mounted rough insets, incorporating cross-top and single lever operating members. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower hose. Model (5840/MBG/W) is supplied with a single lever trim set. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of vertical submersible multistage pumps with either threaded or flanged end connections. Maximum operating temperature 23°C. Open outlet use only.
Peripheral pump for mains water applications with a brass body and impeller, . The pushfit connections on the hoses are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Cold water use only.
Range of shower handsets with plated plastic bodies (various finishes). The inlet incorporates a plastic strainer. Maximum operating temperature 60ºC.
Range of plastic shower handsets available in various finishes. Maximum operating temperature 65°C.
Range of shower outlets with plastic bodies (various finishes). Model 100184782 has flow regulator at the inlet and a shower arm. Maximum working pressure: open outlet. Maximum operating temperature: 70°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets with chrome plated brass bodies incorporating a single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 28450410 is a wall elbow for use with the shower sets and incorporates a check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature: 60.0°C
A Range of drain valves with bronze bodies incorporating brass bonnets, stems and baffles with EPDM seats and O’-rings. The products incorporate a rising spindle operating mechanism. Maximum working pressure 16.0bar. Maximum operating temperature 85°C.
Range of draining taps with DZR brass bodies. Incorporating a rising spindle headwork, EPDM or NBR seals and washers. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Pillar tap (chromium plated brass), incorporating quarter turn ceramic disc with single lever operating members and metal backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome type operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of bath pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and cross top operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 10 Bar. Maximum operating temperature 60°C.
Basin pillar tap (chromium plated brass), incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of deck mounted, fixed or swivel (model 909101 only), self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operating members (see models). The outlets incorporate a plastic flow straightener or aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, fixed, self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operated operating members (see models). The outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of stainless-steel interlocked shower hoses and shower hose extension pieces (smaller length versions) incorporating PE/EPDM and PEX inner tube materials. Available with various surface finishes and end connectors. For further details see model section. Maximum working pressure open outlet use. Maximum operating temperature 85.0°C
Range of (grey or black) nylon or polyethylene braided flexible hose assemblies comprising of a multi-layered hose with a black HDPE outer layer and green PEX inner layer. End connections can incorporate an ‘O’-ring, a washer and/or a V-ring. Washers and ‘O’-rings are EPDM, the V-ring is silicone. Maximum operating temperature 60°C.
Multi-layer PVC shower hoses with silver coating, brass end connections, EPDM gasket and NBR ‘O’-ring. Open outlet use only. Maximum operating temperature 65°C
Adaptor assembly consisting of a brass fitting with EPDM washer and PEX hose. Open outlet use only Maximum operating temperature 60°C
Page 109 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.