Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome or cube operating member incorporating a manual override button. The temperature is controlled by a thermostatic cartridge with dome or cube type operating members incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a lever operating member. Temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Both inlets incorporate an eccentric isolation valve, a stainless-steel strainer and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides back flow protection. The shower outlet connection on the main valve incorporates a flow restrictor (H9741 model only). Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C
Wall mounted thermostatic shower valves (Chrome plated) brass body. Incorporating a quarter turn ceramic disc headwork controlling the flow to the shower handset using a cubed type operating member. The temperature is controlled via a thermostatic cartridge with a cube type operating member incorporating a manual override button. The inlets incorporate stainless steel strainers, screwdriver operated spherical valves and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product includes, a riser rail, shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type, thermostatic shower mixers (chromium plated brass), incorporating a 2 way ceramic disc diverter headwork with a dome type or single lever operating member (see model) controlling the flow between each shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type or single lever operating member (see model) incorporating a manual override button. Both inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. All models, except the X-KCTD model are supplied with an overhead shower rose. All products are supplied with a shower hose. All models are supplied with a shower handset, except for the X- prefix models. The following models incorporate additional items on the inlets to the overhead shower or shower handset: KCTSDEF, KCTSDEFMH: Overhead shower and shower handset with a stainless steel strainer and flow restrictor on the inlet. AOSCTSDEF, SJKRDS01CP & SJKRDS01BK: Overhead shower with a stainless steel strainer and flow restrictor on the inlet, shower handset with a plastic flow regulator on the inlet. AOKCTSDEF, RUDCTSDEF: Shower handset with a plastic flow regulator on the inlet. DCTWDEF: Overhead shower with a plastic flow regulator and a combined EPDM washer and stainless steel strainer on the inlet, shower handset with a plastic flow regulator on the inlet. KHCTADEF, KRCTADEF, ASCTADEF: Overhead shower and shower handset with a plastic flow regulator on the inlet. X-ASCTADEF: Overhead shower with a plastic flow regulator on the inlet. X-AOSCTSDEF: Overhead shower with a stainless steel strainer and flow restrictor on the inlet. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
A range either concealed or exposed wall mounted thermostatic mixing valves with brass bodies (exposed models are chromium plated). Models F3004, F2301, F2304, F2303 incorporate ¼ turn ceramic disc headworks. Model F2304, F2092, F2302 incorporate a manual diverter with a shut off. All models incorporate a thermostatic cartridge that controls the temperature, expect model F3002 that incorporates a combined shut off a thermostatic cartridge with single lever operating members. Model F3004 has a single lever operating member for the headwork and a cross top operating member for the thermostatic cartridge. The inlets of all models expect F3004 incorporate stainless steel filters and approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Range of concealed thermostatic mixing valves, incorporating quarter turn ceramic disc headworks, with dome type operating members, controlling the flow to multiple shower outlets. The temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporates stainless steel strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 65036+54073 supplied with a shower handset and hose. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Wall mounted, thermostatic shower valve (chromium plated brass). Flow is controlled by a quarter turn ceramic disc headwork with single lever operating member. Temperature is controlled independently by a thermostatic cartridge with a cross-top operating member that incorporates a manual override button. The product is supplied with a shower rail and overhead shower. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Wall mounted, concealed, thermostatic blending valve with brass body and chrome plated trim set. Incorporating a thermostatic cartridge headwork with dome type operating member incorporating a manual override button. The valve is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of wall mounted, thermostatic, shower mixers incorporating brass bodies (various finishes) 2-way ceramic disc diverter headwork to control the flow between two shower outlets with various operating members (see model). Temperature is controlled independently via a thermostatic cartridge using various operating members (see model) that also incorporates a manual override button. The inlets incorporate a combined EPDM washer and stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the overhead shower incorporates a combined EPDM washer and stainless-steel strainer. The products are supplied with a shower head, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Concealed, thermostatic shower blending valve, incorporating a brass body and a (chrome plated) trim set. The trim set comprises of a 2 way ceramic disc diverter headwork with a dome type operating member controlling the flow, and a thermostatic cartridge controlling the temperature with a dome type operating member incorporating a manual override button. The trim set is also supplied with two brass assemblies comprising of a plastic filter, EPDM ‘O’-rings and an approved check valve cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection.. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted exposed thermostatic mixing valves with brass bodies (various finishes). Incorporating a ceramic disc headwork with single lever operating member controlling the flow of the outlet on the bottom of the valve and three push button cartridges, two control the flow to outlets at the rear of the valve, and one to the outlet on the bottom of the valve all with cube type operating members. The temperature is controlled independently via thermostatic cartridge with a dome type operating member with a manual override button. The inlets and outlet at the bottom of the valve incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum working temperature 65°C.
Range of wall mounted exposed thermostatic mixing valves with brass bodies (various finishes). Incorporating a ceramic disc headwork with a single lever operating member controlling the flow to a hose outlet and then two push button cartridges, one controls the flow to an outlet at the rear of the valve and the other to the outlet on the bottom of the valve with cube type operating members. The temperature is controlled independently via thermostatic cartridge with a dome type operating member with a manual override button. The inlets and outlet at the bottom of the valve incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets incorporate stainless steel strainers. Maximum working pressure 10.0 bar. Maximum working temperature 65°C.
Wall mounted, exposed thermostatic shower valve (brass body, various finishes) incorporating a non-rising spindle headwork controlling the flow with a dome operating member. The temperature is controlled independently via a thermostatic cartridge with a dome operating member which incorporates a manual override button. Both inlets incorporate stainless steel strainers and an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type thermostatic shower mixers (various finishes). Incorporating a quarter turn ceramic disc headwork controlling the flow to the outlet with a dome type operating member. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member with a manual override button. Both inlets incorporate stainless steel strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of lugged and wafer type butterfly valves with blue epoxy coated bodies, incorporating EPDM rubber ‘O’-rings and seat, and either a bronze (AB2), stainless steel (CF8 & CF8M) or blue epoxy coated ductile iron (DI) disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of lugged and wafer type butterfly valves with blue epoxy coated bodies, incorporating EPDM rubber ‘O’-rings and seat, and either a bronze (AB2), stainless steel (CF8 & CF8M) or blue epoxy coated ductile iron (DI) disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of adjustable in-line pressure reducing valves, the inlets incorporate a stainless-steel strainer. Models TS-504-505 & TS-506-508 have brushed chrome, DZR brass bodies. Model TS-501-503 has a DZR brass body. Maximum supply pressure 8.0 bar. Maximum outlet pressure 1.0 bar to 6.0 bar. Maximum operating temperature 85°C.
Range of pressure reducing valves with nickel plated DZR brass bodies, internal stainless steel filter, EPDM ‘O’-rings and diaphragm. Adjustable outlet pressures between 0.5 and 6.0 bar. The products are supplied with an optional pressure gauge. Maximum inlet supply pressure 16.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass bodies, internal stainless steel filter, EPDM ‘O’-rings and diaphragm. Adjustable outlet pressures between 1.0 and 6.0 bar Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass bodies, internal stainless steel filter, EPDM ‘O’-rings and diaphragm. Adjustable outlet pressures between 1.0 and 6.0 bar. Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass bodies, internal stainless steel filter, EPDM ‘O’-rings and diaphragm. Adjustable outlet pressures between 1.0 and 6.0 bar Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass bodies adjustable between 1.0 and 6.0 bar. The valves incorporate a stainless steel strainer. Maximum supply pressure 25.0 bar or 16.0 bar (see model). Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass bodies, internal stainless steel filter, EPDM ‘O’-rings and diaphragm. Adjustable outlet pressures between 1.0 and 6.0 bar Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
Range of normally open, non-latching solenoid valves with brass bodies and an EPDM diaphragm. The inlet incorporates a stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of normally closed solenoid valves with brass bodies, stainless steel spring, EPDM seal and diaphragm. Maximum working pressure 9.80665 bar. Maximum operating temperature 85°C.
‘1175B’ range of servo-controlled normally closed (NC), normally open (NO) or latching solenoid valves with off-white nylon bodies, incorporating a NBR diaphragm with POM diaphragm inserts. For use with copper tube manufactured to EN1057 or John Guest Speedfit barrier pipe manufactured to BS7291 part 3. Maximum working pressure 10.0 bar. Cold water use only.
Range of quarter turn, lever handle or butterfly operated spherical valves with nickel plated brass bodies, chrome plated brass balls and PTFE seals. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of lever operated spherical valves incorporating brass bodies (nickel plated), brass balls (chrome plated) and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Gate valve with an blue epoxy coated cast iron body, EPDM packing and seal. The valve operates via a hand wheel. Maximum working pressure 16.0 bar. Cold water use only.
Range of gate valves incorporating bronze bodies and wedges. The valves operate via a non-rising spindle headwork with lock shield or hand wheel operating members. Maximum working pressure 20.0 bar. Maximum operating temperature 85ºC.
Range of gate valves incorporating blue epoxy coated ductile iron body and EPDM coated wedge. The valves operate via a non-rising spindle headwork with hand wheel operating member. Maximum working pressure 17.24 bar. Maximum operating temperature 85°C.
Range of angle valves (chromium plated brass bodies) with EPDM O-rings and washers. The products incorporate non-rising spindle headworks with dome type operating members. Maximum working pressure 10 bar. Maximum working temperature 80°C.
Range of double regulating valves incorporating bronze bodies, brass disc face (½” - ¾” models) or PTFE (1” - 2” models), PTFE plate and NBR ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of in line double regulating valves with DZR brass bodies, EPDM ‘O’-rings and PTFE valve seals. The valves incorporate a non-rising spindle headwork regulating the flow and isolation function with a handwheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of double regulating valves incorporating bronze bodies, brass disc face (½” - ¾” models) or PTFE (1” - 2” models), PTFE plate and NBR ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of UV disinfection units with stainless steel bodies and quartz tube. Maximum working pressure 10.0 bar. Cold water use only.
Range of UV disinfection units with stainless steel bodies and EPDM seals. The UV lamps are housed inside quartz tubes. Maximum working pressure 10.3 bar. Maximum operating temperature 40°C.
'Delrin® FG511DP NC010'. White coloured, injection moulded semi-opaque acetal material. For use with water up to 85°C.
'SOLID-02'. Factory applied, black coloured, bituminous coating. Apply as per manufacturer's user instructions 'File No.: SOLID-0069, Vison: SLD-03, Date of issue: 2015-01-01'. Cure for 2 hours @60°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'EPACRETE EPAPOX 25 & EPAPROOF FPCS WFC'. Factory applied, cream coloured (once mixed and applied), two-part polyurea coating system. 'EPACRETE EPAPOX 25’ is a two-component epoxy primer which is to be mixed in a 2:1 weight ratio and applied in accordance with manufacturer’s TDS ‘EN 1504-2’, revision date 01.140317. ‘EPAPROOF FPCS WFC' is a two-component polyurea coating which is to be mixed in a 1:1 ratio and applied in accordance with manufacturer’s TDS ‘EN 1504-2’, revision date ’01-2020’. Cure for 24 hours at 25°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Eurokote® 47-20 Brun Rouge'. Factory applied, red coloured (once mixed and applied), two-component epoxy coating. Mix resin and hardener in an 80:20 mass ratio and apply as per manufacturer's instructions dated '15/06/2021'. Cure for 7 days@20°C. For use with water up to 60°C. his material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'E0-850-5210-001'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instructions 'nr.01, rev.00, issue 01' dated 01/082016. Cure for 30 minutes@210°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'AMMT-001G Two Component Epoxy Resin Coating/Ceramic Epoxy Coating'. Factory applied, off-white coloured, two-component epoxy coating. Components A and B are preheated to 60°C, mixed in a volume ratio of 1:1.& applied as per manufacturer's instructions 'version 2.00', dated '11/01/2021'. Cure for 1 hour@60°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'POWTON E5000P-WT'. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's TDS 'issue reference SPI 20170215' dated 21st January 2015. Cure for 15 minutes@230°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'POWTON E5000P-WT (grey)'. Factory applied, grey coloured, epoxy powder coating. Apply as per manufacturer's TDS dated January 21st 2015. Cure for 15 minutes@230°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Jotaguard VA 5001'. Blue coloured, factory applied, Fusion Bonded Epoxy Powder Coating. Apply as per manufacturer's application guide dated 'October 2018'. Cure for 5 minutes@245°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Vandex Super'. Site applied, two-component, grey coloured (once mixed) cementitious coating. Mix cement powder with water in a weight ratio of 5:2. Apply as per manufacturer's Instructions for Use '2nd issue', dated '18.11.2020'. Cure for 21 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘Sikalastic P 770’ (formerly known as ‘MasterSeal P 770’) Primer for use with ‘Sikalastic M 808’ (formerly known as ‘MasterSeal M 808 Grey’, and ‘MasterSeal M 808 Light Grey’) topcoats. Site applied coating system, which is light grey coloured (once mixed and applied), comprising of a primer and polyurethane coatings. Coat 1 primer: Mix parts A & B of ‘Sikalastic P 770’ Primer in a weight ratio of 2.2:2.8. Apply as per manufacturer’s IFU ‘version No. 1’, dated ‘22nd November 2024’. Cure for 24 hours@7°C. Coat 2 (coating): Mix parts A & B of ‘Sikalastic M 808’, dark grey coloured (once mixed) polyurethane coating in a weight ratio of 3.3:1.7. Apply as per manufacturer’s IFU ‘version No. 1’, dated ‘22nd November 2024’. Cure for 6 hours@7°C. Coat 3 (water contact coating): Mix parts A & B of ‘Sikalastic M 808’, light grey coloured (once mixed) polyurethane coating in a weight ratio of 3.3:1.7. Apply as per manufacturer’s IFU ‘version No. 1’, dated ‘22nd November 2024’. Cure for 7 days@7°C. When applying the coating system to GRP there is no need to apply a primer. Mix, apply and cure ‘Sikalastic M 808’ dark grey and then mix, apply and cure ‘Sikalastic M 808’ light Grey (water contact layer) as detailed above. For use with water up to 23°C.
‘Intergard 269 & Interline 975’. Site applied, white coloured Epoxy coating system comprising of a base coat and a topcoat. ‘Intergard 269’ is a two-component base coat which comprises of Part A (red/brown coloured) and Part B (straw coloured). Mix Part A & Part B in a mass ratio of 7.46:1 and apply as per manufacturer’s TDS ref. ‘206’, dated 08/02/2021. Cure for 12 days@25°C. ‘Interline 975’ is a two-component topcoat which comprises of Part A (white coloured) and Part B (straw coloured). Mix Part A & Part B in a mass ratio of 3.12:1 and apply as per manufacturer’s TDS ref. ‘3577’, dated 31/07/2017. Cure for 14 days@25°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 71 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.