Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating a ceramic cartridge headworks, and various operating members. The spout outlet incorporates a flow straightener and is also supplied with an optional aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating a quarter turn ceramic disc headworks, and various operating members. The spout outlet incorporates a flow straightener. Product is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The product is supplied with optional ⅜” BSP (M) x ½” BSP (F) adaptors each with a fibre gasket for installation on each inlet hose. The product is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Single hole, single outlet deck mounted (fixed) combination tap assembly with soap dispenser and hand dryer appliances operated via an infra-red sensor. This product incorporates a solenoid valve and plastic flow restrictor. Maximum working pressure 10.0 bar. Maximum operating temperature 50°C.
Range of single hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with a pop up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet wall mounted (fixed) combination tap assembly with soap dispenser and hand dryer appliances operated via an infra-red sensor. This product incorporates a solenoid valve and plastic flow restrictor. Maximum working pressure 10.0 bar. Maximum operating temperature 50°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating quarter turn ceramic disc headworks with cross-top operating members. The inlet hose assemblies incorporate a servicing valve and is supplied with a single check valve assembly verified by test (suitable for backflow protection against Fluid Category 2). The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headwork with cross-top operating members. The inlet hose assemblies incorporate a servicing valve and is supplied with a single check valve assembly verified by test (suitable for backflow protection against Fluid Category 2). The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes).Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a flow straightener and is supplied with an optional plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with (chrome plated) brass bodies. Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a aerator. Inlets incorporate single check valve cartridge (however the the complete assembly has not been tested to demonstrate it provides adequate backflow protection)Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass). Incorporating ceramic cartridge headworks, single lever operating members and pull down spray with pre-rinse trigger mechanism incorporating an approved check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) Both inlet hoses incorporate an approved check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole single outlet fixed combination tap assemblies incorporating brass bodies (variety of finishes) and quarter turn ceramic disc headwork with either cross top or single lever operating members. The spout outlets incorporate a plastic aerator and the products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole single outlet fixed combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating quarter turn ceramic disc headwork with cross-top operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap incorporating a brass body (chrome plated), quarter turn ceramic disc headworks and EPDM ‘O’-rings. The spout outlet incorporates a plastic flow straightner. Product is supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a manual diverter to shower with a single lever operating member. Flow is controlled via a ½ turn ceramic disc headworks with cross top operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC
Two-hole single outlet fixed combination tap assemblies incorporating a brass body (variety of finishes), quarter turn ceramic disc headwork with single lever operating members and manual diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with a cross-top operating member. The products are supplied with a flow regulator, shower handset, shower hose and shower head. The spout outlets incorporate a plastic aerator. The inlets of the tap and the outlet of the shower handset incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole deck mounted combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headworks with either cross top or single lever operating members. The products incorporate a manual diverter to a shower outlet with a single lever operating member and the spout outlets incorporate plastic aerator. The products are supplied with a shower handset, shower hose and metal back nuts. Maximum working pressure 5 bar. Maximum working temperature 60°C.
Deck mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener or an optional aerator. The product is supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, cross top operating members and self cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headwork with either single lever or cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (chrome plated brass) incorporating quarter turn ceramic disc headworks with single lever or dome type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (various finishes) incorporating quarter turn ceramic disk headwork with cross-top operating members. The inlets incorporate approved single check cartridges however the complete assembly has not been tested to demonstrate it provides back flow prevention. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet combination tap assembly with brass bodies (chrome or nickel plated finish, see model) incorporating quarter turn ceramic disc headworks, various operating members, a lockable diverter to the shower outlet and a swivel spout. The shower outlet on the main body incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The spout outlet incorporates a plastic flow straightener, also supplied with an optional areator. The product is supplied with a shower hose and handset and metal backnuts Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc headwork with either single lever or cross top operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three-hole, metal, single outlet (fixed) combination tap assemblies (chrome plated brass)) incorporating quarter turn ceramic disc headworks and either single lever or cross top operating members (see model). The spout outlets incorporates a plastic aerator and the products are supplied with a lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with various operating members. The headworks are connected to the spout via stainless steel braided, PEX lined flexible hose assemblies. The spout outlets incorporate a plastic flow straightener and the products are supplied with a lever operated pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed, wall mounted, three hole, single outlet (fixed) combination tap assemblies (various finishes) incorporating quarter turn ceramic disc headwork and cross top operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted three hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic flow straighterner and is also supplied with an optional aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headwork and cross top operating members (models RIV6 CHR & RIV6 GOLD) or dome type operating members (all other models). The spout outlet incorporates a plastic flow straightener and is supplied with an aerator. The products are also supplied with TAQ PEX lined flexible connecting hose assemblies, intended for use between sidebody valves and spout. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Functional trim set (chrome plated), comprising two quarter turn ceramic disc headworks with either single lever (models ending in 882) or cross top (models ending in 892) operating members and a spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks with various operating members and manually operated diverter to a shower hose and handset. The spout outlet incorporates a plastic flow straightener and is also supplied with an optional aerator. The outlet to the shower incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted bath spout outlet incorporating a brass body (chromium plated) and a plastic flow straightener. Maximum operating temperature 60°C.
Expansion vessels incorporating a stainless steel body and EPDM membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 100˚C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Unidelta range of compression fittings with polypropylene bodies with EPDM ‘O’ rings for use with PE100 polyethylene pipe (manufactured to EN12201). Maximum working pressure 16.0 bar. Cold water use only.
Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of outdoor air to water heat exchanger units incorporating a pump, drain valve and isolation valve. Maximum working pressure 5.0 bar. Maximum operating temperature 90°C
Range of water meters with black epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of hand wash and dryer units The flow is controlled by a solenoid valve activated via an infra-red sensor. The products are supplied with a non-verifiable double check valve assembly (suitable for backflow protection against Fluid category 3) for installation on the inlet. The double check valve assembly also incorporates a drain port, (located in between the cartridges), and an integral spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 50ºC.
Pressure gauge with a plastic case, brass connector and bronze spring tube. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of flow and temperature sensors with stainless steel bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of circulation fittings with gun metal bodies, plastic cones & guides and EPDM ‘O’ rings. The products incorporate a dynamic venturi valve. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Pressure manager pump control unit with a plastic body. The outlet incorporates a non-return valve. Maximum working pressure 10.0 bar. Cold water use only.
Page 43 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.