Range of check valve cartridges with plastic bodies to be housed in specifically dimensioned bodies. The product incorporates a plastic flow regulator. Maximum working pressure 16.0 bar & maximum operating temperature 65°C.
Non-verifiable single check valve assembly consisting of a spring loaded, resilient trim, single check valve cartridge with a brushed chrome DZR brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of single check valve assemblies incorporating DZR brass bodies. Maximum working pressure 10 bar. Maximum operating temperature 85°C.
Range of in-line, non-verifiable single check valve assemblies with DZR brass bodies and spring loaded, resilient trim check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC
Non- verifiable double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a chrome plated DZR brass body with an integral insolation valve between the cartridges. For use with copper pipes to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies (DZR brass bodies) incorporating spherical valves and either red or blue butterfly handles. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body (chrome plated or brass finish) with a port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks incorporating NBR ‘O’ rings and silicone seals. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic disc headworks incorporating brass bodies and NBR ‘O’-rings. For insertion into any specifically dimensioned tap assemblies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of quarter turn ceramic disc and cartridge headworks with plastic bodies to be inserted into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of quarter turn ceramic disc headworks with metal bodies to be inserted in specifically dimensioned bodies. Maximum working pressure 17.0 bar. Maximum operating temperature 85°C.
Range of headwork assemblies with brass bodies incorporating a quarter turn ceramic disc headwork. Maximum working pressure 17.0 bar. Maximum operating temperature 85°C.
Range of quarter turn ceramic disc headworks with brass bodies (various finishes on the stem), silicone seals, and EPDM ‘O’-rings for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and silicone gaskets. The products are intended for insertion into specifically dimensioned tap bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of thermostatic cartridges incorporating brass bodies (GH25W, GH35W) or plastic body (GH35T), and NBR ‘O’-rings. For insertion into specifically dimensioned bodies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of single hole single outlet fixed combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The product incorporates a plastic flow regulator in the spout body, and a plastic aerator in the spout outlet. Certain models are supplied with click type waste (See models). Maximum working pressure 10 bar. Maximum working temperature 60 °C.
Wall mounted single-hole, single outlet, fixed, combination tap assembly with a brass body in a variety of finishes (See models). Incorporating a ceramic disc headwork with a dome type operating member. The temperature is controlled separately via a rotary ceramic cartridge headwork that can also be used as a shut off with a dome type operating member. The inlets to the tap incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and plastic flow regulator. Maximum working pressure 10 bar. Maximum working temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, metal, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate plastic aerators. The 31 609 xxx model is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 5 bar. Maximum operating temperature 85°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener (AX-MAT-137-CP) or plastic aerator (AX-ROW-137-CP). The product is supplied with metal back nuts. Maximum working pressure 5 bar. Maximum operating temperature 85°C
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. To be used with rough set 13622180. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of concealed two hole, single outlet (fixed) wall mounted tap assemblies, with a brass bodies and chrome plated trim set. Consisting of a rough in set 63397 and external trim 65088 and 65089. Incorproating a ceramic cartridge headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with dome type operating members (922036 model only) and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The 922308 and 922317 models are also supplied with an optional plastic aerator. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly with brass body (various finishes). Incorporating quarter turn ceramic disc headworks, and self cancelling diverter to shower outlet. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see models). The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies with M8 x ⅜” captive nut end connections and a combined NBR washer and stainless steel strainer (x2) for installation between the side valves and the brass tee piece to the spout. The inlets of the brass tee piece incorporate an approved single check cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose fibre gaskets for installation on each inelt hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Range of three hole, single outlet (fixed) wall mounted, concealed tap assemblies with brass bodies and chrome plated trim set. Consisting of a rough in set 45089 and extermnal trim 65090 and 65091. Incorproating a quarter turn ceramic disc headworks and single lever operating members.The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlet incorporates a self-cancelling diverter to the shower outlet and a plastic flow straightener with stainless steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to the shower outlet and a plastic flow straightener with a stainless-steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to shower outlet and a plastic flow straightener with stainless steel mesh. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
A range of four-hole single outlet fixed combination tap assemblies with brass bodies in a variety of finishes (See models). Incorporating ¼ ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator. The shower outlet elbow incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. This product is supplied with a shower hose, shower handset and metal screw clamp type back nuts. The side valves and the spout are connected with a copper tube. Maximum working pressure 10 bar. Maximum working temperature 60 °C.
‘CD3 Series’ chlorine dioxide dosing system incorporating a single check valve positioned at the point of injection. Maximum working pressure 6.0 bar. Cold water use only.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Models VB8, VB12, VB18 & VB24 have a maximum working pressure of 16.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of filling loop assemblies, comprising of a stainless steel braided EPDM lined hose, isolation valve with a DZR brass body and ball and an isolation valve with a DZR brass body and ball incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The F1400120012211 model has an isolation valve incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3) at each end of the filling loop. All items except the hoses are nickel plated. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of copper press fittings with EPDM seals for use with EN1057 copper tube. The joints are achieved by means of a press tool. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Boss Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass tee fittings for use with copper pipe to EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of end feed copper solder fittings for use with copper tube. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
Page 27 of 158
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.