Range of DZR brass couplings incorporating EPDM ‘O’-rings for use with Uponor Ecoflex Aqua and Uponor Ecoflex VIP Aqua PE-Xa pipe. For above and below ground use. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
>B< Press range of stainless-steel SUS316L fittings for use with 316L stainless steel tube manufactured to EN10312. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Dual flush WC outlet valve with an ABS body, incorporating a silicone seal and internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
WC dual flush drop valve comprising of a plastic body, silicone seating washer and an internal overflow. The valve is operated via a push button assembly (not included) for either full or reduced flush. Cold water use only.
Range of plate heat exchanger with stainless steel bodies. Maximum working pressure10 bar. Maximum operating temperature 100°C.
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Range of commercial ice making machines with flow controlled via solenoid valve. Maximum working pressure 8 bar. Cold water use.
Range of water meters with blue epoxy coated iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of three or four-hole single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Four hole models Incorporate quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to a shower outlet.. Three hole models Incorporate a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to a shower outlet. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. The product is supplied with a shower hose and shower handset. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of pressure transmitters with stainless steel bodies. Maximum working pressure 10.0 to 200.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of spout outlets with brass bodies (various finishes) incorporating an aerator. Product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of brass (chrome plated) quick fit connectors. Maximum operating temperature 60°C
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (46553 - Stuart CH 4-30 & 46554 - Stuart CH 4-40 models) or 9.0 bar (46555 - Stuart CH 4-50 &46556 - Stuart CH 4-60 models). Maximum operating temperature 65°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of brushless DC centrifugal pumps with a plastic body. Maximum working pressure 1.0 Bar. Maximum operating temperature 70°C.
Range of single and twin shower booster pumps with brass bodies, DZR brass impellers, NBR ‘O’-ring and EPDM seals. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Shower head with a brass body (various finishes), incorporating EPDM O- rings and a stainless-steel strainer at the inlet. Maximum operating temperature 60.0°C
Wall mounted outlet bracket incorporating a brass body (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 60°C.
Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Range of shower outlets (celing or wall mounted arms - see model) with chrome plated brass bodies and silicone nozzles. The products incorporate a swivel joint connection to the shower head which incorporates a combined NBR washer and stainless steel strainer. All models, except for the 15199 model, include a plastic flow regulator on the inlet to the shower head. Maximum operating temperature 60°C.
Range of overhead shower outlets with brass bodies (various finishes, see model), incorporating stainless steel strainer and flow regulator on the inlets. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated ABS plastic bodies. Maximum operating temperature 65°C
Range of shower arms, ceiling arms, water intakes and wall mounted outlet brackets (all models excluding INOX are chrome plated brass, INOX models are stainless steel). Maximum operating temperature 60.0°C
Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The 1BCB001 & 1BCB701 models incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated) brass bodies with quarter turn ceramic disc headworks and single lever type operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
‘Tempomix 3’ range of self-closing combination tap assemblies (chromium plated brass) with spring loaded headwork controlling both the flow and temperature with a dome type operating member. The spout outlets incorporate a plastic flow straightener. The inlet hoses each incorporate a plastic strainer and a plastic flow restrictor either side of an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The 794000 and 79400015 models are supplied with ⅜” BSP (M) x ⅜” captive nut inline isolation valves. The 79400015 model is also supplied with a ⅜ BSP (M) x ½” BSP (M) brass adaptor. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of plastic shower hoses (chrome effect finish) incorporating a PVC inner liner, with EPDM ‘O’-rings and/or washers. Maximum operating temperature 60°C.
Range of stainless steel braided HDPE lined flexible hose assemblies incorporating EPDM ‘O’-rings and/or washers depending on end connection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel or nylon braided PEX lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided, PEX lined flexible hose assemblies with a variety of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies incorporating EPDM washers and ‘O’-rings, and various end connections, some of which include a brass bodied screwdriver operated spherical valve with chrome plated brass ball (see model). For use with copper pipe (EN 1057) Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies incorporating EPDM washers and ‘O’-rings, and various end connections, some of which include a brass bodied screwdriver operated spherical valve with chrome plated brass ball (see model). For use with copper pipe (EN 1057) Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of 2, 3 or 4 way manifolds with a brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, manually operated, concealed blending valves with brass bodies (chrome plated) faceplates, incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Wall mounted, exposed, manual blending valve (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member controlling both flow and temperature. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of deck mounted, manually operated, concealed blending valves with chromium plated brass bodies and either brass or stainless-steel trim (see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The product is supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ¾” captive nut end connection for installation on the outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
A range of wall mounted thermostatic blending valves with brass bodies (various finishes). The temperature is controlled via a thermostatic cartridge and dome operating member and flow is controlled via a quarter turn ceramic headwork. Product can come with one, two or three push type cartridges that divert the flow to various outlets (see model) The inlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Concealed electronic thermostatic shower valve with a plastic body, the flow is controlled via two motorised valves for hot and cold supply. Both inlets incorporate a plastic strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7 bar. Maximum working temperature 65°C.
Range of wall mounted thermostatic blending valves with brass bodies (chrome plated), incorporating two way diverter valves controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°.
Range of concealed thermostatic shower valves with brass bodies incorporating a quarter turn ceramic disc headwork controlling the flow to the shower outlet model VV135-IS incorporates a single shower outlet (x1 headwork) and model V134-IS incorporates a double shower outlet (x2 headworks). The temperature is controlled independently via a thermostatic cartridge. Both inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of concealed, wall mounted, thermostatic mixer valves with brass bodies (various finishes) with 1 - 6 outlets. Flow is controlled to each outlet by ‘detent’ (push to on push to off) headworks. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate a combined plastic washer and stainless steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model SL-T50004BW has a maximum working pressure of 10.0 bar. All other models have a maximum working pressure of 6.0 bar. Maximum operating temperature is 85°C.
Range of wall mounted, exposed bar type thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork controlling the flow with a dome operating member and manual override button. The temperature is controlled by a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless-steel strainer and single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar type thermostatic blending valves (chromium plated brass) incorporating a 2-way manual diverter valve controlling and diverting the flow between an overhead shower and a shower outlet with dome type operating members, model (34458892) is supplied with cross-top operating members. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the overhead shower incorporates a stainless steel strainers and flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Page 27 of 125
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.