Range of shower hoses incorporating stainless steel interlocking outer with PVC inner liner or PVC outer and PVC inner liner (see model). Maximum operating temperature 65°C.
Range of chromium plated stainless steel or brass interlocked shower hoses with an optional PVC outer layer. Incorporating either a PVC or TPE inner hose and EPDM gaskets. Maximum operating temperature 60°C.
‘PARINOX/STRONGFLEX S-200' range of stainless-steel braided EPDM lined flexible hose with various end connections (see model). Compression connections are for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
McDonald Steel Flow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
SSB, SSI SST range of stainless steel unvented cylinders provided with an unvented kit supplied with cylinders containing a temperature and pressure reducing valve set at 3.0 bar and an expansion vessel and single check valve (suitable for fluid category 2) . Available as storage tank, indirect or twin coil. Maximum working pressure of the cylinder 6.0 bar, maximum working pressure of the coil or coils 12.0 bar. Maximum operating temperature 95°C.
Range of wall mounted, exposed, bar type thermostatic shower mixers (chromium plated brass) with a 2-way ceramic disc diverter controlling the flow to either shower outlet. Temperature is controlled independently via a thermostatic cartridge which incorporates a manual override button. The S06 model has dome type operating members and the S15-2 model has cube type operating members. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed, thermostatic mixing vales with brass bodies and chrome plated trim sets, incorporating one or two quarter turn ceramic disc headworks with various operating members (see models). Temperature is controlled independently via a thermostatic cartridge with various operating members (see model) which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic blending valves (chromium plated brass) incorporating a quarter turn ceramic disc headwork (with various operating members). The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved check valve cartridge(s), however, the complete product has not been fully tested to demonstrate it provides backflow protection and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature is 85°C.
Range of water filters cartridges with plastic bodies and either carbon block or activated carbon filter media. Maximum working pressure 8.6 bar. Maximum operating temperature 38°C.
Wall mounted exposed thermostatic shower valve incorporating a brass body (various finishes), quarter turn ceramic disc headwork with single lever operating members and manual diverter to shower outlet. The temperature is controlled independently via a thermostatic cartridge with cross top type operating member. The inlets incorporate a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). The product is supplied with an overhead shower, shower handset, riser rail and shower hose. Maximum working pressure 5.0 bar Maximum operating temperature 60°C.
Range of wall mounted thermostatic shower valves (chrome plated) brass bodies incorporating a single sequential thermostatic cartridge controlling both flow and temperature. Models 86005770 & 86005780 have single lever operating members. Model 86005760 is not supplied with an operating member. both inlets incorporate single check valve cartridges (suitable for backflow protection against fluid category 2). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic shower valves incorporating brass bodies (chrome plated) and a quarter turn ceramic disc headwork controlling the flow with single lever, cross top or dome type operating members. The temperature controlled is independently via a thermostatic cartridge incorporating a manual override button with cross top, dome type or single lever operating members. Both inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete assemblies have not been fully tested to demonstrate that they provide adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic bar shower valve, riser rail, shower handset, shower hose and overhead shower outlet. The valve incorporates a brass body (chrome plated) and ceramic disc headwork with dome type operating member which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. The inlets incorporate stainless steel filters and a single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Thermostatic cartridge with brass body, and EPDM ‘O’-rings. For insertion into specifically dimensioned bores. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Wall mounted thermostatic blending valve (chrome plated brass) incorporating a quarter turn ceramic disc headwork with dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button. The inlets incorporate approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature is 60°C.
Range of wall mounted, concealed, thermostatic shower blending valves incorporating stainless steel bodies, a 2-way ceramic disc headwork and a single lever operating member controlling the flow. The temperature is controlled independently via a thermostatic cartridge with a single lever incorporating a manual override operating member. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic bar type shower mixing valves (chromium plated brass). The246PG model incorporates a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between an overhead shower outlet and a shower handset. The 536PG model incorporates a quarter turn ceramic disc headwork with a dome type operating member controlling the flow to a shower handset. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. Both inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Both products are supplied with a shower hose and handset, the B36264 model also includes a shower riser to an overhead shower outlet. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wafer and lugged type, concentric butterfly valves with epoxy coated cast iron bodies, austenitic steel discs and EPDM seats. Maximum working pressure 16.0 bar. Cold water use only.
Range of butterfly valves incorporating blue epoxy coated ductile iron bodies & wedges and EPDM sealing gasket. The closing mechanism is controlled by a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85˚C.
Range of lug type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs, EPDM seats and lever type operating member. Maximum working pressure 16.0 bar (models 2108 12, 2108 13 and 2108 14). Maximum working pressure 10.0 bar (models 210816 and 2108 18). Maximum operating temperature 100°C.
Range of lug type butterfly valves incorporating blue epoxy coated cast iron bodies, stainless steel discs, EPDM seats and lever type operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of shower bars with brass bodies (various finishes), incorporating a manual diverter with cube or dome type operating members, which diverts between an overhead shower and a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
2-way ceramic disc diverter with a plastic body, NBR ‘O’-rings and silicone seals. For insertion into specifically dimensioned bores. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of wall mounted, concealed flow control valves with brass bodies, incorporating either one or two quarter turn ceramic disc headworks with single lever operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
‘Europress’ range of in-line pressure reducing valves, with DZR brass bodies and EPDM ‘O’-rings and washer. The outlet pressure is adjustable between 1.0 - 5.5 bar. Operating parameters: 2430012 EUROPRESS model: Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C. 2430034 EUROPRESS & 2430100 EUROPRESS models: Maximum inlet supply pressure 16.0 bar. Maximum operating temperature 99°C.
Range of adjustable pressure reducing valves incorporating a plastic body and EPDM ‘O’-rings and stainless steel strainers. Outlet pressure 1.2 - 8.0 bar. Maximum inlet supply pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pressure relief valves pre-set @ 6.0 bar, incorporating DZR brass bodies, EPDM seal cup and EPDM ‘O’-ring. Maximum operating temperature 99˚C
‘EV220A-W’ range of normally closed solenoid valves with brass bodies, EPDM diaphragms and ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Aquatsop leak detection system intended to shut the water supply in the event of a water leak. Consisting of two single normally closed servo controlled solenoid valves with a flow regulator and stainless steel filter at the inlet. A LDPE inner hose with corrugated plastic outer hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of angled isolation valves with brass bodies (brushed chrome plated), for use with copper tube manufactured to EN1057. The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of spherical valves with bronze bodies, DZR brass ball (sizes ½” to 1”) and bronze ball (sizes 1 ¼” to 2”) PTFE seats and various operating member types (see models). Maximum working pressure: 25.0 bar. Maximum operating temperature: 85⁰C.
Range of gate valves incorporating brass bodies and wedges with EPDM ‘O’-rings and a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves incorporating ductile iron epoxy coted bodies and with EPDM ‘O’-ring seals and discs. The valves are operated via a non-rising spindle with a hand wheel operating member Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of 115 gate valves with blue epoxy coated ductile iron bodies and EPDM coated ductile iron wedges. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of commercial dishwashers with flow controlled by a solenoid valve and discharged via a type AB air gap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 4.0 bar. Cold water use only.
Range of water conditioners incorporating a static PTFE and zinc anode in a brass or nickel plated bronze body. Between November 2021 and December 2023 the maximum working pressure is: ET/ETD models = 10.0bar, EF/EF-16 models = 16.0 bar, EF-40 models = 40.0 bar. From January 2024 the maximum working pressure is: ET/ETD/EF/EF-16 models = 16.0 bar & EF-40 models = 40.0 bar. Maximum operating temperature 60°C.
Range of electrolytic scale inhibitors incorporating copper bodies. For use with copper pipe complying with BS EN 1057. Maximum working pressure 10.0 bar. Maximum operating temperature 40°C.
Range of UV disinfection units with stainless steel and EPDM seals. The UV lamps are housed inside synthetic quartz tubes Maximum working pressure 6.9 bar. Cold water use only.
Hostaform®, injection moulded POM materials. For use with water up to 85°C: Hostaform® Special Grade: M25AE 10-2013 & M25AE 10-2013 ECO-B (black coloured). Hostaform® Glass Bead Filled Grade: C9021 GV3/30 NATURAL. Hostaform® M30RS Natural & M30RS ECO-B NATURAL. For use with water up to 65°C: Hostaform® Unfilled Grades: T1020 NATURAL. Hostaform® Glass Fibre Filled Grades: C9021 GV1/10 NATURAL, C9021 GV1/20 NATURAL, C9021 GV1/30 NATURAL, C9021 GV1/30 3134 NATURAL & C9021 GV1/30 3134 ECO-B NATURAL. Hostaform® Glass Bead Filled Grades: C9021 GV3/10 NATURAL & C9021 GV3/20 NATURAL. Hostaform® Special Grades: M25IE natural, M25IE ECO-B NATURAL & M30AE. Between April 2021 and 2nd August 2022, these grades were for use with water up to 65°C. Between 3rd August 2022 and 30th April 2026, these grades are for use with water up to 85°C: Hostaform® Unfilled Grades: M15HP NATURAL, M15HP ECO-B NATURAL, C2521 NATURAL, C2521 ECO-B NATURAL, C9021, C9021 ECO-B NATURAL, C 9021 ECO-C 872 NATURAL, C13021 NATURAL, C13021 ECO-B NATURAL, C 13021 ECO-C 872 NATURAL, C13031 NATURAL, C13031 ECO-B NATURAL, C 13031 ECO-C 872 NATURAL, C27021 NATURAL, C27021 ECO-B NATURAL & C 27021 ECO-C 872 NATURAL. Hostaform® Lubricated Grades: C9021 M (Natural colour is grey), C9021 M ECO-B NATURAL, C9021 FCT1 NATURAL, C9021 FCT1 ECO-B NATURAL, C9021 TF NATURAL, C9021 TF ECO-B NATURAL, C9021 K NATURAL, C9021 K ECO-B NATURAL, C13021RM NATURAL & C13021RM ECO-B NATURAL. Hostaform® Special Grade: MR130ACS NATURAL & MR130ACS ECO-B NATURAL. These grades were added January 2022. Between January 2022 and 2nd August 2022, these grades were for use with water up to 65°C. Between 3rd August 2022 and 30th April 2026, these grades are for use with water up to 85°C: Tarnoform® 200 CE natural, 300 CE natural, 400 CE natural, 411 CE natural & 500 CE natural. Between April 2021 and xx February 2023, these grades were for use with water up to 65°C. Between 16th February 2023 and 30th April 2026, these grades are for use with water up to 85°C: Hostaform® Unfilled Grades: C 52021 NATURAL & C 52021 ECO-B NATURAL. Tarnoform® 700 CE. Hostaform® Special Grades: C13031 XAS-G NATURAL, C13031 XAS-G ECO-B NATURAL, M25AE NATURAL, M25AE ECO-B NATURAL & HF M25AE ECO-C 872 NATURAL. For use with water up to 65°C: Grade added February 2023: Hostaform® M25AE 10/5358 DW. Grade added April 2025: Hostaform® MR130 ACS 10/5358 DW Black. For use with water up to 85°C: Grade added April 2025: Hostaform® M25AE 10/5358 DW black.
`POWLAC EY161`. Factory applied, blue coloured epoxy powder coating. Apply as per manufacturer's instructions `no. CKP-2015-0172`. Cure for 5 minutes@180°C. For use with water up to 85°C. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'ELASTOPOXY PRIMER HP and ELASTOSEAL W Coating'. Factory applied, grey coloured (once mixed), two-component primer (non-water contact primer) and two-component coating (water contact coating). Mix and apply 'ELASTOPOXY PRIMER HP as per Product Data Sheet ‘TSS/TD/280721/C’. Cure for 2 hours@25°C. Then mix and apply ‘ELASTOSEAL W Coating’ as per Product Data Sheet ‘TSS/TDS/260721-B’. Cure for 1 minute@25°C. For use with water up to 85°C.
'SYI-03'. Factory applied, grey coloured, Portland cement mortar. Mix cement, sand and water in a mass ratio of 1:1.5:0.6. Cure for 4 hours@23°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Nu Vista'. Factory applied, grey coloured Portland Slag Cement. Mix water, sand and cement in a mass ratio of 1:2:3. Cure for 1.5 hours@30°C, then 4 hours at 45°C and then 28 days (672 hours)@35°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'TML Dalmia Infra Pro'. Factory applied, grey coloured Portland Slag Cement. Mix water, sand and cement in a mass ratio of 1:2:3. Cure for 1.5 hours@30°C, then 4 hours@45°C and then 28 days (672 hours) @35°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'SC2 Coating'. Factory applied, clear, PTFE based coating. Apply and cure as per manufacturer's instructions 'LDAP-002 issue 1' dated 09-08-2016. For use with water up to 85°C.
'Protecfull SFP 108'. Factory applied, two-component, cream coloured polyurethane coating. Mix part A & part B in a 75:25 volume ratio and apply as per manufacturer's instructions reference '016. Ed.01.21' dated August 24, 2021. Cure for 7 days@23°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempaline Defend 630 Cure 72'. Factory applied, white coloured, two-component epoxy coating. Mix base and curing agent in a 3:1 volume ratio and apply as per manufacturer's product data sheets dated June 2021, Cure for 6 days@20°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 24 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.