Range of WC flushing cisterns incorporating a BS 1212-4 (2016) side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres or 4.5/3 litre flush volumes. The cistern is operated by a manual push button and the product incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush pneumatic outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Incorporating a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of floor mounted, single hole, single outlet (fixed), combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator (SH-T9050N model) or a plastic flow straightener (all other models). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of in-line non-verifiable single check valve assemblies consisting of a spring loaded resilient trim single check valve cartridge housed within a brushed chrome DZR brass body. For use with copper pipe EN1057. Fitting also incorporates a stainless steel strainer For maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of in-line, non-verifiable single check valve assemblies with DZR brass bodies and spring loaded, resilient trim check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC
Range of Caprice assisted baths which include a choice of with or without a hoist. Flow is controlled via a thermostatic mixing valve supplying the bath spout outlet or shower handset. The discharge from the bath spout and shower handset in via a type AUK 3 airgap, verified by measurement, suitable for Fluid Category 5 backflow protection Maximum working pressure 6.0 bar.
Non-metallic materials and components comply with BS6920 at 46°C
Range of wall mounted, electrically heated catering water boilers. The boilers incorporate stainless steel storage tanks with stainless steel vent and overflow and silicon washers and gaskets, fed via a solenoid valve. The water is discharged via a self-closing tap with single lever operating member. The solenoid valve incorporates a plastic strainer at the inlet. Maximum working pressure 7.0 bar. Maximum operating temperature 98°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings, for insertion into specifically dimensioned bores. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of ceramic disc and non-rising spindle headworks headworks incorporating brass bodies and NBR ‘O’-rings. For insertion into any specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM rubber ‘O’-rings for insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of thermostatic cartridges with brass or plastic bodies (see model) and EPDM ‘O’-rings. The GR-FX-02S, 03SC, 10T, 11T, X02S, X02T & X05 models incorporate a stainless-steel strainer. For insertion into specifically dimensioned bores. Maximum operating temperature 75°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies with stainless steel bodies (in various finishes). The flow is controlled by a solenoid valve activated via an infra-red sensor. The solenoid housing attaches to the main tap body via (black) LLDPE tubing. The spout outlets incorporate a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. The products are available either as a version with a pop-up waste or one with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes – see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporate a plastic aerator. The A42722VUK model is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies, incorporating brass bodies (various finishes). Model 3034-CR has a non-rising spindle headwork with cross top operating members. All other models have a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies, incorporating brass bodies (various finishes), ceramic cartridge headwork with a single lever operating member and waterfall spout outlet. The waterfall spout outlets of models 3110-CR, 3110M-CR & 3260-CR incorporate a stainless-steel mesh. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a lever type pop-up waste. Maximum working pressure 5.0 Bar Maximum operating temperature 65°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with either a single lever or dome type operating member (see model). The spout outlet incorporates a plastic aerator (specific models only - see model section). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies, incorporating brass bodies (various finishes). Model A05406 has a non-rising spindle headwork with cross top operating members. All other models have a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a waterfall type with or without a stainless-steel mesh (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes). Incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. This product also incorporates an additional spring-loaded quarter turn ceramic disc headwork with a single lever operating member for filtered cold water discharged from the spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes - see model) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener (TR1027 and TR1005 models) or a plastic aerator (all other models). The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted two-hole, metal, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic disc diverter headwork controlling the flow between the spout outlet and the shower outlet with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating members that incorporates a manual override button. The spout outlet incorporates a plastic aerator. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (various finishes, see models). Incorporating ceramic cartridge headworks and single operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of five-hole, single outlet (fixed) combination tap assembly (chromium plated) brass bodies incorporating a quarter turn ceramic disc headworks to control the flow with single lever operating members. The product is supplied with stainless steel braided EPDM lined flexible interconnecting hose assemblies to connect between the valves and a lockable self-cancelling diverter that controls flow between spout and shower handset. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
Range of combined bath fillers and overflow waste assemblies (plated brass covers and plastic hoses) with pop-up wastes. Maximum operating temperature 65ºC. Open outlet use only.
A range of spout outlets with PVC lined stainless steel interlocked tube covered by silica gel. Model WD-PVC-09-10 is a double outlet. Maximum working temperature 65°C.
Filling link assembly with a nylon body and EPDM ‘O’-rings. The product incorporates a screwdriver operated shut off valve and two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The product is also supplied with two screwdriver operated angled spherical valves and a mounting bracket. Maximum working pressure 10.0 bar. Cold water use only.
A range of water filter cartridges with polypropylene bodies. Maximum working pressure 8.6 bar. Cold water use only.
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of DZR brass couplings incorporating EPDM ‘O’-rings for use with Uponor Ecoflex Aqua and Uponor Ecoflex VIP Aqua PE-Xa pipe. For above and below ground use. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Pexal range of brass press fittings with EPDM ‘O’-rings for use with copper pipe EN1057. Model VS0171373 incorporates 90° copper elbow (chrome plated) Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
>B< Press range of stainless-steel SUS316L fittings for use with 316L stainless steel tube manufactured to EN10312. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). The AF14 and AF15 tap connector models incorporate an EPDM washer. Maximum working pressure 16.0 bar. Maximum working temperature 85˚C
‘Tectite Sprint’ range of pushfit fittings with copper or DZR brass bodies. 10mm, 15mm, 22mm & 28mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) and polybutylene barrier pipe and cross linked PEX barrier pipe (manufactured to BS 7291). 35mm, 42mm & 54mm pushfit fittings are for use with copper pipe (manufactured to BS EN 1057) only. When used with PB & PEX pipes operating parameter are: 12.0 bar@cold water. 3.0 bar@92°C. When used with copper pipes operating parameter are: 20.0 bar@cold water. 10.0 bar@100°C.
Electric instantaneous, vented mains water heater with plastic a housing and silicon rubber hose. Maximum operating temperature 98°C.
Under counter electric instantaneous water heater with a stainless steel tank. The flow is controlled via a solenoid valve. The product is supplied with a 3 way isolation valve (15mm compression x 15mm compression x ¾” BSP (M)), as well as a filter head and filter cartridge for installation prior to the under counter unit. LLDPE tubing and pushfit connections are provided for connecting between these items. The filter head inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet to the under counter unit incorporates a combined silicone washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 98˚C. Cold water supply only.
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Hydraulic block assembly comprising of a flow regulator, central heating pump assembly and a stainless-steel plate heat exchanger. Maximum working pressures: DHW circuit: 10.0 Bar Central heating circuit: 2.5 Bar Maximum operating temperature: DHW Circuit: 65.0°C Central heating circuit: 90.0°C
Spout end flow control device (aerator with ‘switchable’ spray formation). Maximum operating temperature 65°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (46553 - Stuart CH 4-30 & 46554 - Stuart CH 4-40 models) or 9.0 bar (46555 - Stuart CH 4-50 &46556 - Stuart CH 4-60 models). Maximum operating temperature 65°C.
Range of brushless DC centrifugal pumps with a plastic body. Maximum working pressure 1.0 Bar. Maximum operating temperature 70°C.
Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.
Range of self-priming jet pumps with stainless steel bodies. Maximum working pressure 6.0 bar. Maximum operating temperature 45°C
Ranges of overhead shower outlets with brass bodies, chrome plated plastic shower handsets, shower sets and shower kits. The shower sets comprise of a chrome plated plastic shower handset and shower hose. The shower kits comprise of a chrome plated plastic shower handset, brass wall elbow and either stainless steel interlocked, or PVC coated, shower hoses. The inlets of the shower handsets incorporate a plastic flow regulator at the inlet. Shower kits with ½” (M) inlets are also supplied with a brass wall elbow which incorporate a plastic flow regulator and an approved single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). Maximum operating temperature 60°C.
Page 21 of 83
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.