Range of multistage pumps with brass impellers and stainless steel shaft, incorporating an approved check valve cartridge, however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
Range of overhead shower outlets (chromium plated ABS plastic bodies). Incorporating a combined EPDM washer and stainless-steel strainer on the inlet. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets (chromium plated ABS plastic bodies). Incorporating a combined EPDM washer and stainless-steel strainer on the inlet (all other models). Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of anti-vandal shower outlets, (brass bodies – chrome plated finish), incorporating a flow regulator on the inlet. Open outlet use only Maximum operating temperature 65.0°C
Range of wall elbows with brass bodies (chromium plated) incorporating two check valves cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Wall elbow with brass body (chromium plated) incorporating two check valves cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of overhead shower outlets, (chrome plated brass bodies) incorporating flow regulators on the inlets. Model (716000) is wall mounted, all other models are ceiling mounted. Maximum operating temperature 60.0°C
White plastic shower handset. Maximum operating temperature 60°C
Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C
Range of shower kits comprising of ABS bodied shower handsets and PVC multi-layer hoses incorporating EPDM ‘O’-rings. Supplied with riser rail. Available in various finishes. Maximum operating temperature 60°C
Range of wall mounted shower outlets (chrome plated or white finish). Products either incorporate a filter or a dummy unit for the insertion of a filter. Models 02-092034, 02-092039, 02-803150 & 02-092031 incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Overhead shower outlet with a stainless-steel body and EPDM seals. Maximum operating temperature: 85°C.
Shower handset with a chrome plated ABS plastic body. Maximum operating temperature 85°C.
Range of shower handsets (brass bodies – various finishes). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line Y patterned strainers with bronze bodies and a stainless steel mesh strainer. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C
Range of deck mounted, two hole or single hole laboratory taps (fixed or swivel) with brass bodies, incorporating rising spindle headworks with either dome type or single lever operating members. The spout outlets incorporate a hose union spigot connection and the products are supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straighteners. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Self-closing pillar tap (chromium plated brass) with spring loaded headwork and dome operating member. The spout outlet incorporates a plastic aerator. Supplied with brass backnuts. Maximum working pressure 10 Bar Maximum operating temperature 85°C
Range of stainless-steel braided TPS lined flexible hose assemblies incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves Push-fit fittings for use with: Copper Pipes manufactured in accordance with BS EN 1057 PB pipes manufactured in accordance with BS 7291-2 PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure 12.0 bar. Maximum operating temperature 65°C.
‘Qualflex Excel’ range of stainless steel over braided, PEX lined flexible hoses, incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves. Push-fit fittings for use for with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar. Maximum operating temperature: 65°C.
Flexible safety hose assembly with PVC inner hose and corrugated outer cover incorporating EPDM gaskets. The inlet of the hose incorporates a plastic strainer. The hose is fitted with an integral device consisting of a water sensitive material which expands when in contact and is intended to stop the flow of water (please note that this function has not been verified by test). Maximum working pressure: 10.0 Bar. Maximum operating temperature: 60.0°C.
Inlet hose consisting of a EPDM inner hose layer and corrugated outer cover. The hose is fitted with an integral device consisting of a water sensitive material which expands when in contact with water. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of stainless steel or nylon braided EPDM lined flexible hose assemblies with various brass end connections. Compression connection to be used with copper pipe EN1057. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Nylon and stainless-steel braided EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel braided hoses with EPDM liner and NBR or fibre gaskets. DN13 and DN19 Maximum working pressure 10 bar. Maximum operating temperature 65°C. DN25 Maximum working pressure 10 bar. Cold water use only.
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. SCFA models incorporate a spherical valve. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic blending valves, (brass bodies various finishes), incorporating a quarter turn ceramic disc headwork controlling the flow. Temperature is controlled independently via a thermostatic cartridge with a manual override button incorporating dome or lever type operating members, each inlet incorporates a stainless-steel strainer and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower handset, hose and riser rail. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with DZR brass bodies (various finishes). Compression inlets incorporate a stainless-steel strainer and check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Push-fit inlets incorporate a check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. HEAT112050 & HEAT112055 models incorporate angled inlets with integral spherical valves. HEAT112010, HEAT112015, HEAT112050, HEAT112055 – Compression for use with copper pipe (to BSEN1057:2006) only. HEAT155001, HEAT155010 – Push fit for use with PEX pipe (to BS7291 part 3), Polybutylene pipe (to BS7291 part 2) & Copper pipe (to BSEN1057:2006). Maximum working pressure 10.0 bar at 20°C and 7.0 bar at 85°C.
Range of wall mounted thermostatic bar mixers with brass bodies (Chromium or black finish) incorporating a ceramic disc headwork which controls the flow with lever type operating members. Temperature is controlled independently via a thermostatic cartridge with lever type operating member which incorporates a manual override button. The inlets incorporate stainless steel strainers and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with shower handset, hose and riser rail. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Range of wall mounted shower sets comprising of a concealed, shower valve (brass body – various finishes), overhead shower outlet, shower handset, shower hose and wall elbow. The inlets of both the overhead shower outlet and shower handset incorporate a plastic flow regulator. The flow is controlled to separate shower outlets via a manual diverter. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature with a single lever operating member. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with an isolation valve for each inlet. Maximum working pressure; 10 Bar Maximum operating temperature 85°C
Range of wall mounted thermostatic shower valves (chromium plated brass bodies). Flow is controlled by a quarter turn ceramic disc headwork with dome operating member and temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporate a single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic bar shower mixers with brass bodies, incorporating a thermostatic cartridge controlling the temperature and non-rising spindle headwork controlling the flow. The inlets incorporate stainless steel strainers and an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Exposed wall mounted bar shower mixer (chrome plated brass body), incorporating a two-way ceramic disc diverter headwork controlling the flow with a cubed type operating member. Temperature is controlled independently via a thermostatic cartridge with a cubed type member that incorporates a manual override button. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). The product is supplied with a shower handset, shower hose, overhead shower and a riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of butterfly valves with an epoxy coated ductile iron body, stainless steel disc and single lever or handwheel operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of blue epoxy coated butterfly valves with stainless steel discs and EPDM seal. Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Range of gear operated butterfly valves with blue epoxy coated ductile iron bodies. Maximum working pressure 16 Bar Maximum operating temperature 80°C
Manual diverter with a brass body incorporating EPDM ‘O’-rings and seals. Maximum working pressure 6.0 Bar. Maximum operating temperature 70.0°C
Range of two or five way diverter cartridges with plastic bodies. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Two-way ceramic disc diverter with a plastic body, incorporating a press on-off function. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Two-way ceramic disc diverter headwork (2 on, 1 off) with a plastic body and silicone seals. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of fire hydrants with an epoxy coated, cast iron body, operated via a non-rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C
Fire hydrant with a ductile iron body (blue epoxy powder coated) operated via a non-rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of non-return valves housed within a blue epoxy coated ductile iron body. Maximum working pressure 16.0 bar. Maximum operating temperature 80ºC.
Page 163 of 231
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.