Aquaflow range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of black polyethylene electrofusion fittings for use with PE100 pipe (manufactured to EN 12201-2). Please refer to model for maximum working pressures. For below ground and cold water use only.
Dual flush WC outlet valve incorporating an ABS body, operated via a push button assembly or a battery powered infra red sensor for either full or reduced flush. Cold water use only.
Range of automatic urinal flush valves with a plastic body. STD - Maximum working pressure 6.0 bar. LP - Maximum working pressure 0.5 bar. Cold water use only
Range of plate heat exchangers with stainless steel plates, for primary and secondary circulation. Models E040-2M-GB6 and R040-H2M-G6B are secondary use only. Maximum working pressure - R040-HNM-G6B range = 30.0 Bar and E040-NM-GB6 range = 20.0 Bar Maximum operating temperature - 99 °C
Alfa Laval range of copper brazed and stainless-steel fusion bonded, stainless steel heat exchangers in various sizes ranging from 4 plates to 300 plates. Maximum working pressures and temperatures: CB10, CB11, CB15, CB16, CB16AQ, CB18, CB18AQ & CB18DW: S1/S2 circuit: 5 Bar. S3/S4 circuit 10 Bar. Max working temperature 150°C. CB20 & CB20AQ: S1/S2 circuit: 16 Bar. S3/S4 circuit 16 Bar. Max working temperature 225°C. CB65, CB65AQ & CBH65: S1/S2 circuit: 18 Bar. S3/S4 circuit 37 Bar. Max working temperature 225°C. CBH16 & CBH18: S1/S2 circuit: 32 Bar. S3/S4 circuit 32 Bar. Max working temperature 150°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC. Models added March 2023: CBH30: 50 Bar (S1/S2/S3/S4) & 225.0°C, CBH112: 45 Bar (S1/S2) 51 Bar (S3/S4) & 225.0°C, CB30: 41 Bar (S1/S2/S3/S4) & 225.0°C, CB60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB60AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH60: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB62AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CBH62: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB30AQ: 40 Bar (S1/S2/S3/S4) & 225.0°C, CB110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB110AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CBH110: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB112AQ: 37 Bar (S1/S2/S3/S4) & 225.0°C, CB24: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, CB24AQ: 29 Bar (S1/S2) 37 Bar (S3/S4) & 225.0°C, ANTW66: 29.0 Bar (S1/S2/S3/S4), ANTW18: 23 Bar (S1/S2) 28 Bar (S3/S4) 225.0°C and RM11: 15 Bar (S3/S4) & 225.0°C. Maximum operating temperatures detailed above are for primary circuits only, secondary circuits approved to 99oC.
Electric, instantaneous, vented, mains water heaters with plastic housings and silicon gaskets. Model AQ5001353 incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow prevention. Maximum working pressure 1.5 bar.
Non-metallic materials and components comply with BS6920 at 98°C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of static ultrasonic bulk water meters with stainless steel bodies and EPDM 'O'-rings. The products are supplied with two sets of optional (green) gaskets. Maximum operating temperature: Products marked T50: 65°C. Products marked T30: cold water use only.
Range of water meters with blue epoxy coated ductile iron bodies, plastic measurement chambers and vanes and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of in-line ultrasonic water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
Leak detection and prevention device consisting of an inline solenoid valve and flow meter. Maximum working pressure 10.0 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at 23°C
Range of solid copper alloy and bi-metallic flanges. Solid models are bronze, bi- metallic models are bronze with an epoxy coated steel outer flange.
Range of tee pieces with nickel plated brass bodies. Models 0912/15CVCC & 0912/CVCC incorporate a non-return valve (not suitable for backflow prevention) and stainless steel retaining clip. Compression connections to be used with copper pipe to BS EN 1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85˚C.
Wall mounted shower outlet elbow with a chromium plated brass body incorporating EPDM ‘O’-rings. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
‘Alpha’ range of circulator pumps with either a composite (plastic) or stainless steel body, plastic impellor and EPDM ‘O’-rings. The Alpha 1 model B CIL3 has a black motor housing. The Alpha 1 model B and the Alpha 2 model E stainless steel body models have either a black or red motor housing. All other models have a red motor housing. The 1”-1½” models are supplied with EPDM gaskets for the inlet and outlet. The 2” model has fibre/NBR gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of water pressure booster pumps, comprising of a multi-stage pump with a brass body, and an expansion vessel. The product is supplied with a strainer and two stainless steel braided EPDM lined flexible hose assemblies. The outlet assembly incorporates a non-return valve, not suitable for backflow protection. Maximum working pressure models 46601 and 46602 6.0 bar, models 46622 and 46624 9.0 bar. Cold water use only.
Range of centrifugal multi-stage horizontal pressure booster pumps with brass bodies. The 46593, 46594, 46595 and 46610 models include a non-return valve (not suitable for backflow protection) and an expansion vessel. They are also supplied inline strainer and two stainless steel braided EPDM lined flexible hose assemblies with 1” captive nut x 1" BSP (M) end connection for the inlet and outlet. Maximum working pressure models 46578, 46596, 46605 and 46606: 6.0 bar, Models 46593, 46594, 46595 and 46610: 9.0 bar. Maximum operating temperature 65°C
Range of shower handsets with chromium plated ABS bodies with multi-spray patterns. Maximum operating temperature 60 °C.
Range of shower handsets incorporating chromium plated plastic or chromium plated brass bodies (see model). Inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets with ABS plastic bodies (various finishes, see models). Maximum operating temperature (see models).
Range of shower handsets with ABS plastic bodies (various finishes, see models).. Maximum operating temperature (see models).
Range of kits comprising of a shower handset, shower hose and riser rail (various finishes - see models). The shower hose incorporates an EPDM washer and stainless-steel strainer Maximum operating temperature 60°C.
A range of ABS plastic shower handsets, (various finishes - see model). Maximum operating temperature 60°C.
Range of deck mounted pull-out shower hose and handsets (various plated brass or stainless-steel bodies). The inlet to the shower handsets incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature: 60°C
Shower kit consisting of shower handset, EPDM lined shower hose, wall outlet and riser rail, available in various finishes (see model). Maximum operating temperature 85.0°C
Over head shower outlet with a chromium plated brass body, with a swivel function. Inlet incorporates NBR gasket with stainless-steel strainer and a flow regulator. Maximum operating temperature 60°C.
Range of shower handsets incorporating flow regulators on the inlets available in chrome and matte black finishes. Maximum operating temperature 60°C.
Range of chrome plated shower kits consisting of shower hoses with EPDM washers incorporating stainless steel strainers at the captive nut, handsets and riser rail assemblies. Maximum operating temperature 60°C.
Range of overhead showers, shower handsets, shower kits and an angled wall outlet. The ARR-HEAD-CP overhead shower has a brass body and wall mounted arm (chrome plated). The CER-HEAD-C/P overhead shower has a plastic body (chrome plated) and incorporates a combined EPDM washer and stainless steel strainer on the inlet. The shower handsets have plastic bodies (chrome plated). The ARR-SFSRK+O-CP shower kit consists of an angled brass wall outlet (chrome plated), multi-layered PVC lined shower hose (silver external appearance), a plastic bodied shower handset (chrome plated) and a riser rail. The ARR-SFMKWO-CP shower kit consists of an angled brass wall outlet with integral handset holder (chrome plated), multi-layered PVC lined shower hose (silver external appearance) and a plastic bodied shower handset (chrome plated). Maximum operating temperature 60°C.
Screwdriver operated spherical (drain) valve with a brass body, brass ball, PTFE seats and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with a single lever, dome, or cross top type operating member (see models). The spout outlet incorporates a plastic flow straightener. Models are supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks with a single lever, dome, or cross top type operating member (see models). The spout outlets incorporate plastic flow straighteners. Models are supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of pillar taps (brass body in various finishes) incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate plastic flow straighteners. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of PVC or EPDM lined shower hoses with stainless steel outer (chrome or black finish) or PVC reinforced (chrome plated finish) outer layer. Maximum operating temperature 65°C.
Range of PVC multi-layer shower hoses incorporating EPDM washers. Maximum operating temperature 60˚C.
Stainless-steel or nylon braided PEX lined flexible hose assemblies with various end connections (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Stainless-steel or nylon braided EPDM lined flexible hoses assemblies with various end connections (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of Direct & Indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The secondary circuit consists of a temperature and pressure relief valve set at 10.0 bar and 90°C and an alternative temperature and pressure relief valve also set at 10.0 bar and 90°C , an inlet control group consisting of a pressure reducing valve pre-set at 3.0 bar, an expansion relief valve set at 8.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum working pressure - Primary circuit: 6.0 bar & Secondary circuit: 7.5 bar Maximum operating temperature 85.0°C
Range of wall mounted thermostatic blending valves (brass bodies), with ceramic cartridge headworks controlling the temperature and the flow and a manual diverter that diverts the flow to two outlets. Both have single lever operating members. Maximum working pressure 5.0 Bar Maximum operating temperature 65°C.
Range of wall mounted, manual, shower blending valves, comprising of a concealed brass body (rough in set) and a trim set (chrome plated), which includes a ceramic cartridge headwork with a single lever operating member. The 2551 and 2551EP trim set models also have a 90° wall outlet elbow. The 2541 and 2551 models are supplied with a combined plastic filter and plastic flow regulator (x2) for installation on each concealed body inlet. The 2541EP and 2551EP models are supplied with a combined plastic filter and an approved single check valve with a plastic flow regulator (x2), for installation on each concealed body inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The concealed rough in set incorporates a manually operated isolation valve on each inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic shower mixers with brass bodies, dome or cube operating members and a thermostatic cartridge controlling the temperature. Models D1001, LB091, LB092, LB093, LB094, LB095, D2002, LB096, LB097, LB098, LB099, LB100, D3001, LB101, LB102, LB103, LB104 & LB105 incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic blending valves with brass bodies (chrome plated), incorporating two way diverter valves controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°.
Range of wall mounted thermostatic shower valves (various finishes) incorporating a quarter turn ceramic disc headworks with single lever type operating members. The temperature is controlled independently via a thermostatic cartridge with manual override and single lever type operating members. Both inlets incorporate approved single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of concealed, thermostatic blending valves with a brass body. The temperature is controlled via a thermostatic cartridge with a dome operating member which incorporates a manual override, and flow is controlled via a push on/off headwork to a single or optional shower outlet, depending on model. The inlet connections incorporate single check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower mixer with brass body (chrome plated), incorporating a ceramic cartridge headwork ,controlling the flow and temperature and single lever operating member. The shower outlet incorporates an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted shower mixer with brass body (chrome plated face plate), incorporating a ceramic cartridge headwork ,controlling the flow and temperature with single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted blending thermostatic shower valve (chrome plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow. The temperature is controlled independently via a thermostatic cartridge. Both using cube type operating members. The inlets incorporate approved check valve cartridges; however, the complete assembly has not been tested to demonstrate it provides backflow protection. The inlets also incorporate ¾” BSP (M) x 15mm compression (chrome plated) spherical ball valves and EPDM washers incorporating stainless steel mesh strainers. The product is supplied with a chrome plated shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 98 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.