'Astral PVC Gel'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions review date '2019-09-11'. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Range of wall mounted electric showers (various finishes). Incorporate a manually operated push button valve controlling the flow and plastic strainer on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 53°C. Cold supply only.
Range of wall mounted electric showers (various finishes). The GSD models incorporate a solenoid valve controlling the flow, which includes a combined plastic and stainless steel strainer and a plastic flow regulator on its inlet. The GSM/ models incorporate a manually operated push button valve controlling the flow and plastic strainer on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 53°C. Cold supply only.
Range of commercial, front loading, heat pump tumble dryers with flow controlled via a solenoid valve. Maximum working pressure 8.0 bar. Cold water use only.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (brushed stainless steel). The flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. The products are supplied with plastic backnuts and a stainless steel braided PEX lined flexible hose assembly for installation between the tap and the solenoid valve. The HK-Rib model is supplied with a plastic flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (brushed stainless steel). The flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. The products are supplied with plastic backnuts and a stainless steel braided PEX lined flexible hose assembly for installation between the tap and the solenoid valve. The HK-Cha models added September are also supplied with a plastic flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (various finishes, see models). Flow is controlled by a solenoid valve activated via an infra-red sensor. The products incorporate a hand dryer feature that are activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The products are supplied with a metal backnut. Maximum working pressure 8.0 bar. Cold water use only.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic aerator and the inlets incorporates stainless steel strainers. Models 351500 & 351510 incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models are either cold/premixed water only or hot and cold supply with a manually adjustable temperature lever. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.
‘Tubular’ range of wall mounted spout outlets (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The box assembly incorporates a solenoid valve, screwdriver operated spherical valve and the spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 1.0 bar. Maximum operating temperature 65°C
Range of wall mounted, single hole, single outlet (fixed) tap assemblies (chromium plated brass) with a solenoid valve controlling the flow and activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connecting hose. Maximum working pressure 8.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a BS 1212-4 side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only
Range of WC flushing cisterns incorporating a side entry BS 1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cisterns incorporating a BS 1212-4 side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 5.5 litres and a reduced flush of up to 2.7 litres and incorporates a servicing valve and flexible hose on the inlet supply. The cistern is operated by a manually operated push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC flushing cisterns incorporating a BS 1212-4 side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3 litres. The cistern is operated by a manual push button and incorporates a angle valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of flushing valves (gunmetal body) which incorporate a screw down stop valve, spherical valve and air gap to drain. Maximum working pressure 10.0 bar. Cold water use only.
Tundish incorporating a plastic body, nut and olives. The tundish complies with the requirements of air gap to drain. Maximum operating temperature 100°C
Range of tundishes with black plastic bodies. The products comply with the requirements of an air gap to drain.
Non-metallic materials and components comply with BS6920 at 65°C
Range of boiling water dispensers incorporating plastic (3-7.5 litre models) or stainless steel (10-40 litre models) cisterns with silicone ‘O’-rings and seals. The flow to the internal reservoir is controlled via a float valve. The internal reservoir incorporates an overflow which acts a vent. The inlet incorporates a plastic filter. Water is dispensed using either a lever or push button (PLUS models only) operated self-closing tap. Maximum working pressure 5.0 bar. Maximum operating temperature 98°C. Cold supply only.
Range of plastic aerators. Aerators which include ‘gpm max’ in the model name, incorporate a plastic flow regulator. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating ceramic cartridge headworks, and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of floor mounted, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with various - operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Single-hole, single outlet, (swivel), combination tap assembly, (chrome plated brass body) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The inlets incorporate screwdriver operated isolation valves incorporating approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Single hole, single outlet (swivel) combination tap assemblies (brass body - varies finishes incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Floor mounted, single hole, single outlet (swivel) combination tap assembly (brass body – various finishes), incorporating two ceramic cartridge headworks with single lever operating members, with the upper headwork functioning as a manual diverter, diverting flow between the spout outlet and shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with a shower hose and handset. Maximum working pressure: 10 Bar. Maximum operating temperature 65°C.
Wall mounted two hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout incorporates a plastic aerator. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Concealed, wall mounted, three-hole, single outlet (fixed) combination tap assembly (brass body - various finishes) incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar
Non-metallic materials and components comply with BS6920 at 60°C
Sensor control boxes, flow is controlled using a solenoid valve assembly. Flow is activated via infra-red sensor and product incorporates a stainless steel filter and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 75°C.
Filling loop assembly comprising of a spherical valve, stainless-steel braided EPDM lined flexible hose and a double check valve assembly ((suitable for backflow protection against fluid category 3) which incorporates a lever operated spherical valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of in-line water filters with polypropylene bodies. Maximum working pressure 8.5 bar. Cold water use only.
Non-metallic materials and components comply with BS6920 at cold water use only°C
‘Unidelta’ brass compression fittings for use with ‘Unidelta UniTerm’ PEX pipe. Maximum working pressure 8.0 bar @ 85°C, 20.0 bar @cold water use.
‘Buteline Polybutylene Plumbing System’ comprising of DZR brass or plastic fittings for use with Buteline polybutylene, EVOH barrier pipe (white or grey). Maximum working pressure 16 bar @ 23°C, 7.0 Bar @ 82°C.
Primaflow ranges of brass, DZR brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
CB ranges of brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe (manufactured to to BS EN1057:2006 + A1:2010). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
‘Trustlene’ range of electrofusion and spigot fittings, with PE100 or brass bodies, for use with SDR11 PE100 pipe (manufactured to IS 4984: 2016). For use above and below ground. Maximum working pressure 16.0 bar. Cold water use only.
Range of Effast PVC-u solvent welded and/or threaded fittings for use with PVC-u pipe manufactured to (EN1452-2). Maximum working pressure 16.0 bar. Cold water use only.
'Dudley Niagara` range of pneumatically operated single and dual flush drop valves. The flush assembly of the dual flush valve is adjustable to give different flush volumes. The valves are operated via a remote button connected by a plastic tube and incorporates an internal overflow. Cold water use only.
Range of dual flush WC drop valves with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Dual flush WC drop valve with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
Range of dual flush WC drop valves with an internal overflow. The valve is operated via a push button assembly for either full or reduced flush. Cold water use only.
‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCU60 UV’ Command centre that provides instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combinations of solenoid valves and electronic pumps to the outlets. A UV unit is incorporated on the outlet from the chilled water tank. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Hydraulic block incorporating a stainless steel and copper brazed plate heat exchanger, plastic fittings and adaptors, recirculation pump and a flow adjustment valve. Maximum operating temperature: Central Heating Circuit: 90°C, Direct Hot Water Circuit: 65°C. Maximum working pressure: Central Heating Circuit: 2.5 bar, Direct Hot Water Circuit: 10 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Page 9 of 20
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.