Range of wall mounted concealed four-hole, single outlet (fixed) combination tap assemblies (brass body with chrome plated or matt black finish trim set), incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The spout inlet has a compression connection for use with copper pipe (manufactured to EN 1057) and incorporates a plastic aerator on the outlet. The product is supplied with a wall mounted shower outlet elbow with integral handset holder, shower hose and a shower handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of brass elbows for combination tap assemblies with EPDM gaskets and pillars to suit bath mixers. Maximum working pressure 10 bar. Maximum operating temperature 65°C
Wall mounted spout with a brass body (various finishes) and a brass rough kit incorporating a stainless-steel strainer and a plastic flow regulator on the inlet of the spout. Open outlet use only. Maximum operating temperature: 60.0°C (10 942 xx0) and 80.0°C (10 941 180)
Range of stainless-steel braided convoluted hose assemblies and expansion joints with either threaded or flanged end connections. Maximum working pressure: 16bar. Maximum operating temperature: 90oC.
Range of filter housings with plastic bodies. Maximum working pressure 12.0 bar. Cold water use only.
Range of in-line water filter cartridges with polypropylene body. Maximum working pressure 8.618 bar. Cold water use only.
Range of press fittings and pipe. Fittings incorporate EPDM ‘O’-rings Maximum working pressure 10 bar. Maximum operating temperature 95°C
Inoxpres range of stainless-steel crimp fittings with EPDM ‘O’-rings and gasket for use with Inoxpres stainless-steel tube (1.4404 AISI 316L or 1.4521 AISI 444 – annealed or not-annealed). The connection is created by using a pressing tool. For above and below ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 95°C.
Instantor Metric Copper Press Range crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of Cupro- Fit press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Press (TH press profile) and screw/compression fittings with brass bodies for use with Comisa Evo Pipe (PE-RT/AL/PE), for above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
IDC ‘BDGxxx’ range of press fittings with brass or nickel plated brass bodies (see model) incorporating EPDM ‘O’-rings and stainless steel crimp sleeves for use with PEX/AL/PEX multilayer pipe (manufactured to EN ISO 21003). The BDG241 and BDG257 prefix models incorporate an EPDM gasket on the captive nut end connection. Pressfit jointing is achieved by either a U or TH crimping profile. Compression connections are for use with copper pipe 12-28mm (manufactured to EN1057) or Irish copper pipe 14.7-27.4mm (manufactured to EN1057). For above ground use only. Maximum working pressure 10.0 bar. 20, 25 & 26mm pressfit sizes cold water use only. Threaded, compression and 16 & 32mm pressfit sizes maximum operating temperature 95°C. From June 2025: The 20, 25 & 26mm pressfit sizes (TH profile only) maximum operating temperature 95°C.
MecFlow Press (PPSU & Brass) Ranges of press fittings for use with MecFlow Press pipes. Maximum working pressure 10.0 bar. The maximum operating temperature is 95oC.
"Yi Sin" Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Universal plastic compression adaptor kits for use with SAB A16 fitting body (not included as part of this approval) and galvanised steel pipe (manufactured to EN 10255). Maximum working pressure 16 bar. Cold water use only.
Allpex range of end feed capillary fittings and brazing fittings for use with copper tube (manufactured to BS EN 1057). EG fittings have gunmetal bodies, ED fittings have DZR brass bodies & EB fittings have brass bodies. For above ground use only. Maximum working pressure: 6mm – 34mm 25Bar, 34mm -54mm 25Bar, 54mm – 108mm 16Bar, 108mm – 159mm 5 Bar. Maximum operating temperature 30°C
Range of dual flush WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of dual flush syphonic WC flush valves. Cold water use only.
Range of dual flush syphonic WC flush valves. Cold water use only.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C
Ultrims Ultrasonic range of in-line water meters with brass or plastic (-01 suffix models) bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Octave range of water meters with blue epoxy coated cast iron or plastic bodies (see models). Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C
‘Helvatron H2O’ range of ultrasonic water meters with brass bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of concealed rough-in sets with brass bodies, intended for use in conjunction with trim and finish sets. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower hose. Model (5840/MBG/W) is supplied with a single lever trim set. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Pump with a plastic body and impeller. Maximum working pressure 0.3 bar. Maximum operating temperature 98°C.
Peripheral pump for mains water applications with a brass body and impeller, . The pushfit connections on the hoses are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Cold water use only.
Range of shower handsets with plated plastic bodies (various finishes). The inlet incorporates a plastic strainer. Maximum operating temperature 60ºC.
Range of plastic shower handsets available in various finishes. Maximum operating temperature 65°C.
Range of overhead shower outlets with chromium plated brass bodies. For installation with specific rough kit sets, incorporating stainless steel strainers and flow regulators in the inlet. Maximum operating temperature 80.0°C For open outlet use
Concealed, wall mounted elbow fitting with a brass body incorporating EDPM `O`-rings. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 70.0°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets with chrome plated brass bodies incorporating a single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 28450410 is a wall elbow for use with the shower sets and incorporates a check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature: 60.0°C
Range of shower outlets, (brass bodies - various finishes), incorporating ball joints, EPDM ‘O’-rings and NBR rubber seals. Maximum operating temperature 60°C
A Range of drain valves with bronze bodies incorporating brass bonnets, stems and baffles with EPDM seats and O’-rings. The products incorporate a rising spindle operating mechanism. Maximum working pressure 16.0bar. Maximum operating temperature 85°C.
Pillar tap (chromium plated brass), incorporating quarter turn ceramic disc with single lever operating members and metal backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 6.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of bath pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and cross top operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 10 Bar. Maximum operating temperature 60°C.
Range of deck mounted, fixed or swivel (model 909101 only), self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operating members (see models). The outlets incorporate a plastic flow straightener or aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, fixed, self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operated operating members (see models). The outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of stainless-steel interlocked shower hoses and shower hose extension pieces (smaller length versions) incorporating PE/EPDM and PEX inner tube materials. Available with various surface finishes and end connectors. For further details see model section. Maximum working pressure open outlet use. Maximum operating temperature 85.0°C
Range of PE lined, nylon braided (black or grey) flexible hose assemblies. The hoses are available with a variety of end connections with different finishes (see model). Maximum operating temperature 85°C. Open outlet use only.
Range of wall mounted, manually operated, blending valves, incorporating a ceramic cartridge headwork and single lever operating member with a self-cancelling diverter. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Wall mounted concealed three way diverter valve assembly (brass bodies with trim sets in various finishes). Maximum working pressure 10 bar. Maximum operating temperature 70°C
Range of wall mounted exposed shower valves (Brass bodies – various finishes), incorporating single sequential headworks controlling both flow and temperature with single a single lever operating member. Models (BPMO SHXVO C & BPRR SHXVO C) incorporate non-rising spindle headworks controlling the flow with single lever operating members. The temperature is controlled independently via a thermostatic cartridge with cross-top operating members. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate that it provides backflow protection. Models (Mini TS1203 RR C, R2 SHXRR C & KN2 SHXRR C) are supplied with riser rails and overhead shower outlets. Models (R2 SHXVO C, BPRO SHXVO C & BPMO SHXVO C) valve only. All other models are supplied with shower hose, handset and riser rail assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, bar shower mixers, (chrome plated brass bodies) incorporating a thermostatic cartridge controlling the temperature with either dome or cubed type operating members that incorporate manual override buttons and quarter turn ceramic disc headworks controlling the flow with dome or cubed type operating members. The inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure - 6 Bar. Maximum operating temperature - 65°C.
‘Rada’ electronically controlled thermostatic blending valve, with a stainless-steel body, EPDM ‘o’ rings and seals. Maximum working pressure; 13.8 Bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic shower valves, (brass bodies - various finishes) incorporating two push button headworks controlling the flow to the hand shower or overhead shower outlet. The temperature is controlled independently via a thermostatic cartridge with single lever operating member which incorporates a manual override button. The inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Page 57 of 83
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.