Range of wall mounted, two-hole, single outlet (fixed) concealed combination tap assemblies (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a stainless steel strainer with a plastic flow straightener. The product is supplied with metal back nuts. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet, fixed combination tap assembly (chromium plated brass) incorporating ceramic disc headworks with single lever operating members. The product incorporates a waterfall type spout with a stainless steel mesh strainer. The product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass). Incorporating quarter turn ceramic disc headworks with cross-top type operating members and manually operated diverter to shower outlet with a single lever operating member. The product is supplied with a shower hose and handset. The product is also supplied with metal backnuts. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with dome type operating members (922036 model only) and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The 922308 and 922317 models are also supplied with an optional plastic aerator. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly with brass body (various finishes). Incorporating quarter turn ceramic disc headworks, and self cancelling diverter to shower outlet. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with single lever operating member and self-cancelling diverter to shower outlet. The inlets incorporate a stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of floor mounted, two-hole, single outlet (swivel) combination tap assemblies (stainless steel and brass bodies various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 70.0°C
Range of two hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated). Incorporating non-rising spindle headworks with dome type operating members (model 922040) and ceramic disc headwork with single lever operating members (model 922075). The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet fixed combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), quarter turn ceramic disc headwork and choice of single lever or dome type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass spout and trim set), incorporating quarter turn ceramic disc headworks with dome type operating members. The inlet of the spout incorporates a plastic flow regulator, and the spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet, (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks with dome type operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. The spout inlet incorporates a plastic flow restrictor, and the spout outlet incorporates plastic aerator. The products are supplied with click type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes, see models) incorporating quarter turn ceramic disc headworks with wheel type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. Model 65011 and 65012 are supplied with a pop-up waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with various operating members (see models). The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (fixed) combination tap assembly with a brass body (various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever operating members. The products are supplied with two stainless steel braided EPDM lined flexible hose assemblies with ½” captive nut end connections for installation between the side valves and the spout. The spout outlet incorporates a combined plastic aerator. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator and is connected to the headworks via stainless steel braided PEX lined hose assemblies. Model 65015 is supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies with M8 x ⅜” captive nut end connections and a combined NBR washer and stainless steel strainer (x2) for installation between the side valves and the brass tee piece to the spout. The inlets of the brass tee piece incorporate an approved single check cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose fibre gaskets for installation on each inelt hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Rangle of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members and self-cancelling diverter to shower outlet The spout outlets incorporate a plastic aerator is connected to the headworks via stainless steel braided PEX lined hose assemblies. Product is supplied with a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlet incorporates a self-cancelling diverter to the shower outlet and a plastic flow straightener with stainless steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to the shower outlet and a plastic flow straightener with a stainless-steel mesh strainer. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes). Incorporating quarter turn ceramic disc headworks, with various operating members. interconnecting flexible hoses. The spout outlets incorporate a self-cancelling diverter to shower outlet and a plastic flow straightener with stainless steel mesh. The product is supplied with a shower handset that incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of floor mounted, single hole, single outlet fixed combination tap assemblies (chromium plated brass with a self-cancelling diverter to shower outlet. The product incorporates a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate an aerator and the product is supplied with a hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall elbows incorporating brass bodies (various finishes) and various back plates. Maximum operating temperature 95ºC.
Range of wall mounted spout outlets, (brass bodies with various finishes) incorporating a plastic aerator. Maximum operating temperature: 60°C
Range of wall mounted spout outlets incorporating brass bodies (various finishes) and plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
‘CD3 Series’ chlorine dioxide dosing system incorporating a single check valve positioned at the point of injection. Maximum working pressure 6.0 bar. Cold water use only.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Models VB8, VB12, VB18 & VB24 have a maximum working pressure of 16.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of expansion vessels with stainless steel and epoxy coated carbon steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of filling loop assemblies, comprising of a stainless steel braided EPDM lined hose, isolation valve with a DZR brass body and ball and an isolation valve with a DZR brass body and ball incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3). The F1400120012211 model has an isolation valve incorporating two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3) at each end of the filling loop. All items except the hoses are nickel plated. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of carbon block water filters and housings. Maximum working pressure 10.5 bar. Cold water use only.
Range of water filter housings with plastic heads and bodies (various colours - see model), incorporating NBR ‘O’-rings (158087/088/207/208/218/219/261 models only) or with EPDM ‘O’-rings (all other models). Big Blue for Cartridges - Maximum working pressure 6.9 bar (10” filter housings) and 6.2 bar (20” filter housings). Maximum working temp 38°C. All other models - Maximum working pressure 8.62 bar. Maximum working temp 52°C.
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
‘Comisa’ range of brass bodied press-fit and threaded fittings for use with `Comisa’ (PE-RT/AL/PE-LMD) multi-layer pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Boss Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
‘Aquila V4 C1’ range of water meters (brass or bronze bodies) with a plastic working chamber, flow regulator and impellor, and either NBR or EPDM ‘O’-rings. The products are supplied with loose NBR/fibre flange gaskets. Maximum working pressure 16.0 bar. Cold water use only.
A range of water meters incorporating brass or plastic bodies (See models), EDPM ‘O’-rings, plastic strainer on the inlet and a plastic impellor. Maximum working pressure 16.0 bar. Maximum working temperature 85°C (brass bodies) or cold water use only (plastic bodies)
Range of water meter manifolds (also known as double box valves) for use with MDPE pipe (manufactured to BS EN 12201). The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 16 bar. Cold water use only.
Range of flow control valves for domestic hot water with plastic bodies and EPDM ‘O’-rings The products incorporate a motor which adjusts the flow, a flow sensor which measures the flow rate and a plastic filter on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pressure gauge with brass body and a plastic case. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Page 30 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.