‘SharkBite’ range of brass push fit fittings incorporating an EPDM ‘O’-ring. For use with the following pipes: JG Speedfit Layflat Polybutylene Barrier Pipe (JG BPB pipe manufactured to BS EN 7291-2:2010), 'BPEX' Barrier Pipe (JG BPEX pipe manufactured to BS EN 7291-3:2010), Polybutylene barrier pipe (manufactured to BS EN 7291-2:2010), PEX barrier pipe (manufactured to BS EN 7291-3:2010) and Copper pipe (manufactured to BS EN1057:2006). Maximum working pressures and operating temperatures: When used with Polybutylene barrier pipes (manufactured to BS EN 7291-2:2010) and PEX barrier pipes (manufactured to BS EN 7291-3:2010): 12.5 bar, cold water use only. 6.0 bar @ 95°C. When used with copper pipe (manufactured to BS EN1057:2006): 10mm sizes: Maximum working pressure 16.0 bar. Cold water use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. 15-22mm sizes: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C. 28mm size added April 2024: Maximum working pressure 20.0 bar. Cold water use only. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of Redman fittings with mild steel bodies (polyamide coating) for use with Puriton II PE-AL-PE barrier pipe - For above and below ground and cold-water use. Jointing is achieved by hydraulic compression. Maximum working pressures: 12.5 Bar for 63mm SDR 11 PE80 pipe system, 10.0 Bar for 90mm to 180mm SDR 17 PE100 pipe system, 16.0 bar for 90mm to 180mm SDR 11 PE100 pipe system. Cold water use only.
Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of water meter housings. The 4414-WMH-20 (threaded) model has a DZR brass body and a check valve cartridge on the inlet verified by test (suitable for backflow protection against Fluid Category 2). The 4414-WMH-1 & 4414-WMH-2 (compression) models have a brass body and an approved check valve cartridge on the inlet, however, the complete product has not been fully tested to demonstrate that it provides adequate backflow protection. The compression models are for use with copper pipe (manufactured to EN 1057). Maximum operating pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ancillary connections with brass bodies (various finishes). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
`UPM3` range of single stage circulator pumps, with stainless steel or plastic bodies, plastic impellers, ceramic shafts and bearings, EPDM 'O'-rings and seals. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of plastic shower handsets available in various finishes. Maximum operating temperature 65°C.
Range of shower handsets with brass bodies (various finishes – see models), available with various handle finishes. Maximum working pressure: Open Outlet. Maximum operating temperature: 65.0°C.
Range of shower handsets and overhead shower with various finishes. Model HS149 incorporates a stainless steel strainer washer at the inlet. Maximum operating temperature 65°C.
Range of hand showers (various finishes). Maximum operating temperature 65°C
Range of shower panel units incorporating an overhead shower outlet. Flow is controlled via spring-loaded headworks using a push-button mechanism. The shower outlet connection incorporates an approved single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of shower arms and ceiling connectors (brass bodies – various finishes) & overhead shower outlets (plastic bodies - various finishes), incorporating EPDM O rings, plastic flow regulators and stainless-steel strainers. Open outlet use only Maximum operating temperature 60.0°C
Range of shower handsets, plastic bodies. Maximum operating temperature 70 °C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of shower arms and brackets (brass or stainless steel bodies - various finishes). Open outlet use only. Maximum operating temperature 85°C.
Range of nylon or stainless steel braided flexible hose assemblies incorporating a PE-X inner hose, EPDM ‘O’-rings and/or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of PVC lined shower hoses with silicone rubber gaskets and interlocked chromium plated outer coating. For open outlet use only. Maximum operating temperature 65°C.
Range of nylon braided (DG50X model series) or stainless steel braided (DG10X model series), PEX lined flexible hose assemblies with a variety of end connections (see models for full breakdown), including EPDM washers and ‘O’-rings where applicable. Some models are supplied with screwdriver operated isolation valves (see model list). All compression and push-fit fittings are to be used with copper pipe (manufactured to EN 1057). Maximum working pressure: 16 bar. Maximum operating temperature: 85°C.
Range of stainless steel braided, EPDM lined flexible hose assemblies. Models are available with a variety of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and an approved check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 3.0 Bar Secondary: 5.5 Bar Solar: 3.0 bar Maximum operating temperature 90.0°C
Range of non-return, swing gate valves with gunmetal bronze bodies. Maximum working pressure 20.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of pressure reducing valves with a DZR brass body, stainless steel strainer and EPDM membrane. Maximum inlet supply pressure 25.0 bar. Outlet pressure in the range of 1.0-6.0 bar. Maximum operating temperature 80°C.
Range of servicing valves with chrome plated brass balls and brass bodies (chrome plated) with either lever operating or butterfly operating members (see models). Compression connection to be used with copper pipe EN1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85ºC.
Range of lever or butterfly operated spherical valves with brass or nickel plate bodies and ball. Maximum working pressure: Various – see model section. Maximum operating temperature 99.0°C
Range of lever operated spherical valves with DZR brass or stainless-steel bodies and ball. Models beginning with ‘GP’ and ‘GPH’ are for use with copper pipes (manufactured to EN 1057). Models beginning with ‘GPMS’ and ‘GPHS’ are for use with stainless steel (SS316L) pipe (manufactured to EN 10312). Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of bedpan washing & disinfection machines. The flow is controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure - See models Maximum operating temperature - 90 °C
Range of commercial washing machines with flow controlled by solenoid valves and discharged via type AB air gap assembly (verified by test - suitable for backflow protection against fluid category 5). The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
“CN Pressure vessel” range incorporating a HDPE liner. The products have a separate outer layer (with black, blue, grey or natural finishes). The CN Pressure vessel 24x72” D-4 model has a top and bottom opening. Maximum operating pressure 10.5 bar. Cold water use only.
'KAJ1207'. Factory applied, blue coloured epoxy coating. Apply as per manufacturer's instructions 'file no. I01-KAJ1207' dated '2019.1.14'. Cure for 15 minutes@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Hempadur 3556K’. Factory applied, cream coloured epoxy coating consisting of a two-part primer and two-part top coat. The two-part primer is Hempadur 15590 red (56880) and this is mixed in a volume ratio of 7.93:2.14 and applied as per manufacturer's Product Data Sheet dated February 2024. Cure for 24 hours@20°C. The two-part top coat is Hempadur 3556K cream (20320) and this is mixed in a volume ratio of 6.8:2 and applied as per manufacturer's Product Data Sheet dated March 2024. Cure for 7 days@20°C. For use with water up to 35°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'ES 988 DWPU'. Site applied, two-component polyurethane coatings which are available in blue or grey colours (once mixed). Mix Part A (blue or grey opaque liquid) with Part B (amber, translucent liquid) in a 100:30.5 weight ratio and apply as per manufacturer's technical data sheet 'TDS507DWPU.rv2.17102018'. Cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘Sikadur-Combiflex® SG System’ comprising of ‘Sikadur® 31 DW’ epoxy adhesive to be used in conjunction with ‘Sika Combiflex® SG Membrane’. ‘Sikadur® 31 DW’ is a site applied, grey coloured, two-part epoxy adhesive consisting of Part A (white coloured) and Part B (black coloured). Part A and Part B are mixed in a weight ratio of 3:1, applied and cured for 14 days@30°C. ‘Sika Combiflex® SG Membrane’ is a modified flexible Polyolefin (FPO) waterproofing tape to be applied over the adhesive and is approved as the water contact layer. Apply as per ‘Sikadur-Combiflex® SG System’ System Product Data Sheet, ‘Edition: 24/10/2012, Identification no: 02 07 03 02 System, Version: GCC’. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘Sikagard®-1814 - RAL 7035’. Site applied, grey coloured (once mixed), two-component epoxy polysulfide resin coating. Mix Part A (light grey, opaque liquid) and Part B (light yellow, translucent liquid) in a 78:22 weight ratio and apply 2 coats as per manufacturer’s TDS ‘MBS_CC-UAE/Pr_1814_06_23/v1/01_24’. Cure coat 1 for 9 hours@25°C. Cure coat 2 for 14 days@25°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LEXAN EXL1494T-NA8A005T'. Colourless, injection moulded Polycarbonate material. For use with water up to 85°C.
'Icorene 1440 NAT & Icorene 1440 BLK 9001'. Natural (appears off-white) & black, rotationally moulded polyethylene materials. For use with water up to 23°C.
‘Tecotek OP20 BK014 01 0A QF, Tecotek OP20 GR30 BK014 01 0A QF, Tecotek OP20 GR10 BK014 01 0A QF & Tecotek OP20 GR20 BK014 01 0A QF’. Tecotek OP20 BK014 01 0A QF is a black coloured, injection moulded, unfilled PPO/HIPS material. Between February 2024 and April 2025, it was for use with water up to 23°C. Between May 2025 and February 2029, it’s for use with water up to 85°C. Tecotek OP20 GR30 BK014 01 0A QF, Tecotek OP20 GR10 BK014 01 0A QF & Tecotek OP20 GR20 BK014 01 0A QF are black coloured, injection moulded, filled PPO/HIPS materials suitable for use with water up to 85°C.
'NORYL FE1410PW – 73701, NORYL FE1520PW – 73701, NORYL FE1630PW – 73701 & NORYL FE1740PW – 73701'. Black coloured, injection moulded PPE + PS materials. For use with water up to 85°C.
'NORYL FE1410PW - 801' (appears yellow-cream coloured) & 'NORYL FE1410PW - 960' (light-grey coloured). Injection moulded PPE & PS materials. For use with water up to 85°C.
'EH700-144'. Black coloured, compression moulded EPDM material. Shore hardness 72. Tested in-radius size 1.0mm. For use with water up to 85°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies, (Chrome plated - brass bodies). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlets incorporate plastic aerators. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies, (Chrome plated - brass bodies). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlets incorporate plastic aerators. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of spring loaded resilient trim check valve cartridges with a plastic body and EPDM ‘O’-rings. For insertion into specifically dimensioned bores Maximum working pressure 10 Bar Maximum operating temperature 85°C
In-line non-verifiable check valve assembly with integral isolation valve. Consisting of spring loaded resilient trim check valve cartridge housed within a DZR brass body, verified by test (suitable for backflow protection against Fluid Category 2). Compression connection to be used with copper pipe to BS EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of deck mounted single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate plastic aerators, flow straighteners, stainless steel strainers or open outlet type spouts (see models). Some models are supplied with a click type pop-up wastes, that have been verified by test (see models). Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C.
Single hole, single outlet (fixed) combination tap assembies (brass bodies – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating ceramic cartridge headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener or plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Single hole, single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating ceramic cartridge headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener or plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet of the 62638-5101 model incorporates a plastic aerator. The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model), incorporating quarter turn ceramic disc headworks with either cross top, dome type or single lever operating members (see model). The spout outlet, excluding the F6134 & F6144 models, incorporates a plastic aerator. The products are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Page 17 of 24
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.