Wall mounted, three-hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with a click type pop-up waste (verified by test). Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole single outlet (fixed) bath and shower mixers with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model) and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The shower outlet incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets with chromium plated brass bodies incorporating plastic aerators. Maximum operating temperature 60°C. Open outlet use only.
Range of deck mounted spout outlets (brass bodies - various finishes). Supplied with metal backnuts. Open outlet use only Maximum operating temperature: 60°C
Range of wall mounted spout outlets (brass bodies – various finishes) incorporating NBR O-rings and plastic aerators. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C
Wall mounted spout outlet with a brass body (various finishes) incorporating a plastic aerator. Maximum operating temperature 65°C.
Range of cylindrical or tubular expansion vessels with epoxy coated carbon steel bodies. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C
Range of ‘NiroSan’ stainless-steel crimped fittings incorporating EPDM ‘O’ Rings, for use with ‘NiroSan’, ‘NiroSan SF’ & ‘NiroSan -ECO’ stainless-steel pipe (all manufactured to EN10312). The fittings and pipe are assembled using a crimping tool with either ‘M’ (15-108mm), ‘V’ (15-54mm) or ‘SA’ (15-108mm) crimping profiles. For above ground use only. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
‘BORPLUS’ range of PP-RCT Socket Fusion fittings used with ‘BORPLUS PP-RCT FASER COMPOSITE STABIL’ pipe. Maximum working pressures at 16.0 Bar @ 23°C and 6.0 Bar @ 85°C.
Range of Reliable press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of M profile brass press fittings with EPDM ‘O’-rings or gaskets to be used with copper pipe manufactured to EN1057 for above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘Isiflo Sprint’ push fit fittings for use with PE100 pipe (manufactured in accordance with EN 12201), for above and below ground use. Isiflo Sprint Family fittings can be installed with seal liners, support liners and without any liner. Maximum working pressure 16 bar. Cold water use only.
SANHA Press Series 6000 & 16000 and PURAPRESS Series 8000 of press-fit fittings with copper (6000), bronze (8000) and chrome plated copper (16000) bodies and EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Range of blue epoxy coated ductile iron dismantling fittings with EPDM sealing rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Domestic hot water heat recovery unit incorporating a stainless steel plate heat exchanger. The product is supplied with 15mm x 15mm compression 90° elbows for installation on the inlet and outlet. Maximum operating pressure 10 bar. Maximum operating temperature 80°C
‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.
Range of electric instantaneous heated showers, incorporating a solenoid valve to control the flow. Products are supplied with a shower hose and handset. Maximum supply pressure 10 bar. Maximum operating temperature 45°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C
Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of solar assisted direct gas fired condensing storage water heaters with an enamel lining and a titanium anode incorporating a solar heat exchanger (max. working pressure 6,0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of ultrasonic water meters with brass bodies and plastic impellers. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters (blue epoxy coated, cast iron bodies). Maximum working pressure 20 Bar. Maximum operating temperature 30°C
Range of submersible pumps with stainless steel bodies and impellers and NBR gaskets and ‘O’-rings. Cold water use only. .
Range of single or twin booster pumps with stainless steel bodies and stainless-steel impellers. Maximum working pressure 8.0 Bar Maximum operating temperature 90.0°C
Range of showers handsets with plastic bodies. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of PVC lined flexible shower hoses (Various finishes see model). Open outlet use only. Maximum operating temperature 60°C.
Range of wall mounted shower outlets (chromium plated brass bodies). The inlets incorporate check valve cartridges, however, the complete assemblies have not been tested to demonstrate they provide backflow protection. The inlets also include built-in flow regulators. Maximum operating temperature 60.0°C. For open outlet use only.
Range of plastic, stainless steel or brass (see models) shower outlets comprising of a shower handset, shower rails and hose (Models: 58004-46XX and 58004-47XX), a shower handset only (Models: 53401-00XX, 56031-00XX, 53283-04XX, 56565-02XX, 56205-00XX, 56321-20XX and 56183-10XX) or an overhead shower head only (models: 51051-12XX, 54012-31XX, 54112-31XX and 54108-00XX). Models 56565-02XX and 54108-00XX incorporate stainless steel strainers. Maximum operating temperature 60.0°C, open outlet use.
A range of plastic overhead shower heads and shower handsets with various finishes. Maximum operating temperature 65.0°C Open outlet use only
Wall outlet with a stainless steel body incorporating a shower handset holder. Maximum operating temperature 65°C.
Range of wall mounted shower arms with brass bodies (various finishes - see models). Maximum working temperature 70°C.
Range of shower handsets and overhead showers, (ABS plastic bodies – various finishes) incorporating plastic flow regulators at the inlets. Maximum operating temperature 60°C. Open outlet use only.
Range of wall mounted shower arms, (brass bodies - various finishes) incorporating EPDM washers. Maximum operating temperature 60°C.
Range of overhead shower outlets with (brass bodies – various finishes) incorporating stainless-steel filter washers at the inlet. Maximum operating temperature 85°C.
Range of wall mounted hose union taps brass body incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chromium plated brass),incorporating either a non-rising spindle headworks (T6317 only) or a 1/4 turn ceramic disc (all other models) with either dome type, single lever or cross top operating members (see models) and metal backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure; 10 Bar Maximum operating temperature 60°C
Range of pillar taps (chrome plated brass bodies), incorporating either a non-rising spindle headworks (T6308 & T6307M only) or quarter turn ceramic disc headworks (all other models) with single lever, dome type or cross top type operating members (see models). The products are supplied with metal back nuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure; 10 Bar Maximum operating temperature 60°C
Range of wall mounted, self-closing, knee operated tap assemblies (chromium plated brass), incorporating spring loaded headwork with single lever type operating member. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of PVC hoses incorporating EPDM washers. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of PVC, Stainless Steel or Nylon shower hoses with PVC or EPDM inner hoses. Maximum operating temperature 65°C or 80°C (See Models) Open Outlet Use Only
Range of plastic shower hoses with a Black PVC inner liner, NBR O-ring and EPDM gaskets available with either brass or stainless-steel ferrules and barbs. Maximum operating temperature: 65⁰ C.
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless-steel or nylon braided PEX lined hoses, incorporating EPDM O-ring or gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided TPSiV lined flexible hose assemblies incorporating EPDM O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of chromium plated interlocked, PEX lined shower hoses with EPDM rubber gaskets. Maximum operating pressure: 6.0 bar. Maximum operating temperature 85°C.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of air venting valves with a stainless-steel bodies and springs, plastic float and EPDM ‘O’-rings. Maximum working pressure 25.0 Bar. Maximum operating temperature 80.0°C.
Range of air release valves with plastic bodies, EPDM ‘O’ rings and polypropylene floats. Maximum working pressure 16.0 bar. Cold water use only.
Page 115 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.