Chrome plated plastic shower handset incorporating a flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range shower outlets and accessories with brass bodies (various finishes). The inlet of the overhead shower outlet incorporates a stainless steel strainer. Maximum operating temperature 85°C. Open outlet use only.
Range of overhead shower outlets, (brass bodies – various finishes) incorporating NBR O rings. Maximum operating temperature: 65C
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
A range of ‘Y’-patterned strainers with bronze bodies incorporating a stainless-steel mesh strainer and PTFE washers. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wall mounted bib tap with a nickel-plated brass body, chrome plated brass ball, NBR ‘O’-rings and gasket, and PTFE seats. The product incorporates a hose union outlet with an integral plastic flow straightener. Maximum working pressure 20.0 bar. Maximum operating pressure 85°C.
Draining tap with elbow shaped DZR brass body and a rising spindle headwork. Maximum working pressure 15.0 bar. Maximum operating temperature 85°C.
Pillar tap (chrome plated brass body) incorporating quarter turn ceramic disc headwork with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Self-closing combination tap assembly (chromium plated brass) with a spring-loaded headwork controlling both temperature and flow with a dome type operating member. The spout outlet incorporates a plastic flow straightener. The flexible hose inlets incorporate a combined EPDM washer and stainless-steel strainer, as well as an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of self-closing pillar taps (chrome plated brass bodies) with spring loaded headwork and dome type operating member. The spout outlet incorporates a plastic flow straightner. The products are supplied with metal backnuts and stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, self-closing bib tap, (chrome plated brass body) with spring loaded headwork and dome type operating member. The spout outlet incorporates a plastic flow straightner. The inlet incorporates a stainless steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of black HDPE Pipe SDR 11 manufactured to ISO 4427 / DIN 8074 / EN12201. Maximum working pressure: 16 Bar. Maximum operating temperature: Cold water use only.
Range of multilayer PVC hoses. Maximum operating temperature 65°C. Open outlet use only.
Range of stainless steel or black nylon braided PEX lined flexible hose assemblies with brass end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless steel braided PEX lined flexible hose assemblies with EPDM washers and/or ‘O’-rings, and brass end connections. The 15mm compression connection incorporates an isolation valve. The models with compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Range of stainless steel braided, EPDM lined flexible hose assemblies with a variety of end connections (see models for full breakdown), including EPDM washers and ‘O’-rings where applicable. Some models are supplied with screwdriver operated isolation valves (see model list). All compression and push-fit fittings are to be used with copper pipe (manufactured to BS EN 1057). Maximum working pressure: 16 bar. Maximum operating temperature: 85°C.
Range of stainless steel interlocked shower hoses with EPDM O-rings. Maximum operating temperature 65°C. Open outlet use only.
Range of stainless steel or black nylon braided EPDM lined flexible hose assemblies with EPDM washers and/or ‘O’-rings, and brass end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Stainless steel braided or nylon braided PEX lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 Bar Maximum operating temperature 85 °C.
Range of wall mounted, manually blended, shower valves, (brass bodies – various finishes). Incorporating a ceramic cartridge controlling both the flow and temperature. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, manually operated blending valves (brass bodies - various finishes) incorporating a ceramic cartridge headwork controlling both flow and temperature and a self cancelling diverter with a lever type operating member. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of concealed manually operated blending valves with (brass bodies - various finishes), incorporating a ceramic cartridge headwork controlling the flow and temperature, a manually operated diverter to shower outlets and a lever type operating member. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.

Range of wall mounted thermostatic blending shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc two-way diverter headwork controlling the flow with dome or square type operating members. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with dome or square type operating members. The inlets incorporate a stainless-steel strainer and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure; 5 Bar Maximum operating temperature 60°C
Range of wall mounted concealed thermostatic blending valves with (brass bodies - various finishes,). The product incorporates a manual diverter valve which can be limited to control the flow between 1, 2 or 3 outlets, a separate thermostatic cartridge controls the temperature. The inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of plastic smart box blending valves, incorporating a brass flow meter with or without an insulated body (see models). The products incorporate a non-return valve. For use with Polybutylene Barrier Pipe (manufactured to BS EN 7291-2:2010 ) and PEX Barrier Pipe (manufactured to BS EN 7291-3:2010) and Copper Pipe (manufactured to BS EN1057) Maximum working pressure 3.0 Bar. Maximum operating temperature 65.0°C
Range of wall mounted concealed electronically controlled thermostatic shower mixers, incorporating plastic solenoid valves to control the flow to various outlets activated via a remote actuator. The temperature is controlled via two transducers housed within the concealed box. The products incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure: 6.0 bar. Maximum operating temperature: 65°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating ceramic disc headwork which controls the flow to 2 outlets with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of wall mounted thermostatic blending valves, (brass bodies - various finishes) incorporating a single sequential headwork, controlling the flow and the temperature and a manually operated diverter to the shower outlets The inlet on the shower handset incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of flanged butterfly valves incorporating blue epoxy coated ductile iron bodies and discs with EPDM rubber seats. Models incorporate hand wheel operating members. Maximum working pressure 16.0 Bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wafer and fully lugged butterfly valves with a blue epoxy coated cast iron bodies, EPDM seat and a stainless steel or chrome plated iron disc. Products are either handwheel or gear operated. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of lugged and wafer type butterfly valves with blue epoxy coated bodies, incorporating EPDM rubber ‘O’-rings and seat, and either a bronze (AB2), stainless steel (CF8 & CF8M) or blue epoxy coated or nickel plated, ductile iron (DI) disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of wall mounted flow control valves (brass bodies – various finishes) incorporating quarter turn ceramic disc headwork. The valves are supplied with multiple trim sets and operating members. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two way diverter valves, (brass bodies – various finishes). Incorporating a quarter turn ceramic headwork. The valves are supplied with multiple trim sets and operating members. Maximum operating pressure 5 bar. Maximum operating temperature 60°C
Range of spring loaded, non-return valves with ductile iron bodies (blue epoxy powder coated) with stainless steel discs, springs and shafts and EPDM seat. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
A range of spring loaded, resilient trim non-return valves with EPDM seat, blue epoxy coated cast-iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85ºC.
Range of wafer or globe type spring loaded, resilient trim, non-return valves with cast iron bodies (blue epoxy powder coated). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of adjustable, in-line pressure reducing valves with blue epoxy coated, cast iron bodies. SP models: maximum supply pressure 25.0 bar, outlet pressure range 1.5 to 7.0 bar. HP models: maximum supply pressure 25.0 bar, outlet pressure range 3.0 to 12.0 bar. LP models: maximum supply pressure 8.0 bar, outlet pressure range 0.5 to 3.0 bar. Maximum operating temperature 60°C.
Range of pre-set, in-line pressure reducing valves incorporating DZR brass or bronze bodies and a stainless-steel strainer. The valves are supplied with an adjustable pressure range between 0.5-6.0 bar. Maximum inlet supply pressure 25.0 bar; except for 536660 with 16.0 bar. Maximum operating temperature 85°C.
Range of in-line adjustable pressure reducing valves with DZR brass bodies. Maximum supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range 1.5 to 6.0 bar. Maximum operating temperature 65°C.
Range of in-line, adjustable, pressure reducing valves with DZR brass bodies. For use with copper pipe to EN 1057. Maximum inlet pressure 16.0 bar. Outlet pressure adjustable between 1.5 bar & 5.5 bar. Cold water use only.
Range of pre-set pressure relief valves incorporating DZR brass bodies and an EPDM diaphragms and PTFE washers. The valve is fitted with hand operated rotating easing gear. Maximum working – see model. Maximum operating temperature 85°C
Range of monostable/normally closed pilot operated solenoid valves mounted in plastic bodies. Valve bodies can also be mounted together in multiples. Push-fit connections to be used with PTFE tube. Maximum working pressure 10 bar. Maximum operating temperature 70°C.
Range of swing gate valves with blue epoxy coated ductile iron bodies, (metal to metal seal). The valves are supplied with an external weighted arm. Maximum working pressure 16.0 bar. Cold water use only.
Range angle valves with brass bodies incorporating non-rising spindle headworks with dome type operating members. Maximum working pressure 10.0 bar. Maximum working temperature 82°C.
‘Instantor’ range of lever operated spherical valves with brass bodies and balls (chromium plated), incorporating PTFE seats, EPDM ‘o’ rings single lever handles (red or blue). For use with imperial Irish copper pipe (manufactured to IS EN 1057). Maximum working pressure 16 bar. Maximum operating temperature 85°C
Range of brass or chrome plated spherical valves with lever or butterfly handles. Maximum working pressure: ¼”- ¾” - 42 bar, Maximum working pressure: 1” – 2” 35 bar and 2 ½” 28 bar. Maximum operating temperature 60°C
Range of lever operated spherical valves with a nickel-plated brass body and a chrome plated brass ball, NBR ‘O’-rings and PTFE seats. Maximum working pressure 30.0 bar. Maximum operating pressure 85°C.
A screwdriver operated spherical ball valve with brass body, chromium plated brass ball and EPDM O-ring. Maximum working pressure 5.5 bar. Maximum operating temperature 85oC.
Range of spherical valves with PVC-U or ABS bodies and ball (see models).. PVC-U models with a solvent weld pipe connection are for use with PVC-U pipe (manufactured to ISO 1452) and are supplied with a PVC-U solvent cement. ABS models with a solvent weld pipe connection are for use with ABS pipe (manufactured to ISO 15493) and are supplied with an ABS solvent cement. Maximum working pressure 16.0 Bar. Cold water use only.
Page 115 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.