Spring loaded resilient trim in-line check valve cartridge with plastic guide, stem and housing, stainless steel spring and EPDM ‘O’-rings. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of thermostatic cartridges incorporating brass bodies, stainless steel strainers and EPDM ‘O’-rings. For insertion into specifically dimensioned tap bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of deck mounted combination tap assemblies (chromium plated brass) incorporating rising spindle headwork with single lever operating members, swivel spout outlet and separate pull-down spray outlet (with self-closing trigger assembly). The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Models 98008-M001 & 98008-1 are single hole, single outlet. Model 98007-1 is two-hole, single outlet. Model 98001-2 is single hole, double outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted combination tap assemblies (chromium plated brass) incorporating rising spindle headwork with single lever operating members, swivel spout outlet and separate pull-down spray outlet (with self-closing trigger assembly). The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Model 98011-1 is single hole, single outlet. Models 98002-1 & 98002-M001 are two-hole, single outlet. Model 98002MN-2 is two-hole, double outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with a single lever operating member. The inlets incorporate plastic strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets of ‘2820’ incorporate a spherical valve. The spout outlets incorporate a plastic flow straightener and the products are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with a single lever operating member. The inlets of model 2820 incorporates a flow restrictor and spherical valves. The spout outlets incorporate a plastic flow straightener and the products are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. The product is supplied with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating a single sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Product is supplied with a T-Type thermostatic mixing valve. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass), incorporating a thermostatic sequential headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (swivel) combination tap assemblies with (chromium plated) brass bodies, incorporating quarter turn ceramic disc headworks or ceramic cartridge headworks (see models) with single lever operating members. The swivel spout of the TMO35SSCM model is (chromium plated) stainless steel. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated or brushed nickel coated brass), with quarter turn ceramic disk headworks and cube operating members. The spout outlet incorporates a plastic flow straightener. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass) with non-rising spindle headworks and cross top operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 7.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disk headwork’s with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of two hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), Models M33136 & M1006 incorporate a quarter turn ceramic disc headwork with single lever operating members. Models M4306, M4306E & M4306F incorporate a non rising spindle headwork with dome type operating members. Model M4306G incorporate a non rising spindle headwork with cross top operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Two-hole, single outlet (fixed) combination tap assembly with a brass body (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet is a waterfall design. The inlets incorporate plastic flow restrictors. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. The products are supplied with metal backnuts. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly with a brass body (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet is a waterfall design. The inlets incorporate plastic flow restrictors. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assemblies (chrome plated brass) incorporating quarter turn ceramic disk headworks and lever operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet swivel combination tap assembly (chrome plated brass), incorporating non-rising spindle headworks with dome operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating non rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted thermostatic shower mixers with brass bodies (chrome plated), incorporating ceramic disc headworks with dome type operating members controlling the flow and a lockable self-cancelling diverter to shower outlet. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that also incorporates a manual override button. Spout outlet incorporates a plastic flow straightener. Both inlets incorporate a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection) and stainless-steel strainers. Model DYN106 is supplied with a shower hose and shower handset, all other models are supplied with a shower hose, shower handset, riser rail and soap dish. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self- cancelling diverter to the shower outlet. The waterfall spout outlet incorporates a stainless-steel aerator. The product is supplied with metal backnuts, as well as a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of deck mounted two hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc (DLV305B, DLT305B) or rising spindle (CR305 “Bridge”, CR305/501 “Bridge” & GEO305) headworks. Models GEO305, DLT305B and DLV305B incorporate single lever type operating members. Models CR305 and CR305/501 incorporate cross top operating members. The products are supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, double outlet (swivel) combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks and single lever type operating members. The product is supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating quarter turn ceramic discs. No operating members supplied. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks and dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Three hole, single outlet (swivel) combination tap assembly with brass body (various finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted (swivel) spout outlets with chromium plated brass bodies, EDPM ‘O’-rings and a plastic flow straightener. DJ suffix models have a double swivel arm. Maximum operating temperature 65°C.
Range of brass compression fittings for use with copper pipe (manufactured to IS EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of Irish compression fittings with brass bodies, nut and olives for use with Irish copper pipe manufactured to EN1057:2006+A1:2010. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of compression fittings incorporating polypropylene bodies, plastic pipe liners, plastic grip rings and EPDM seals. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 12.5 bar (PE80 pipe 20mm - 63mm). Maximum working pressure 16.0 bar (PE100 pipe 20mm - 63mm). Maximum working pressure 10.0 bar (PE100 pipe 75mm - 110mm). Cold water use only.
Range of crimp fittings with a bronze body incorporating EPDM O-rings. For use with copper pipe manufactured to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C

Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.
Range of unvented electric storage water heaters consisting of a mild steel, glass/enamel coated tank, heating element and pressure relief valve set at 6.0 bar. Maximum working pressure 5.5 bar. Maximum operating temperature 75°C.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Q4000 range of water meters incorporating stainless steel bodies, FKM rubber gasket and grey epoxy resin liner. Maximum working pressure 16.0 bar. Cold water use only.
H4000 range of helical rotor bulk water meters, with blue epoxy coated cast iron bodies and NBR ‘O’-rings. Maximum working pressure 16.0 Bar. Cold water use only.
Range of flow meters incorporating black epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Wall mounted outlet with detachable shower hose connector (42037UK model) and wall mounted shower outlet (42018UK model). The 42018UK model is supplied with an optional, detachable shower hose connector assembly which incorporates an integral plastic flow regulator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 42037UK has a maximum operating temperature of 80°C. Model 42018UK has a maximum operating temperature of 60°C.
Wall bracket with a brass body (chrome plated) and EPMD ‘O’-rings. Maximum operating temperature 85°C.
Range of 2,3 or 4 way manifolds incorporating a nickel plated brass body with non-rising spindle stop valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of shower outlet elbows with brass bodies (chrome plated,with exception of model 27.076.LS0). Some models incorporate a shower handset holder. The outlet incorporates a check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Page 1 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.