Range of capillary solder ring fittings (bronze body) for use with copper tube (manufactured to to BS EN 1057). Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of brass compression fittings for use with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of Irish compression fittings with brass bodies, nut and olives for use with Irish copper pipe manufactured to EN1057:2006+A1:2010. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of compression fittings incorporating polypropylene bodies, plastic pipe liners, plastic grip rings and EPDM seals. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. For above and below ground use. Maximum working pressure 12.5 bar (PE80 pipe 20mm - 63mm). Maximum working pressure 16.0 bar (PE100 pipe 20mm - 63mm). Maximum working pressure 10.0 bar (PE100 pipe 75mm - 110mm). Cold water use only.
Range of capillary end feed bronze fittings for use with copper tube (manufactured to BS EN 1057). 15mm – 54mm fittings have a maximum working pressure of 25.0 bar. 67mm – 108mm fittings have a maximum working pressure of 16.0 bar. Maximum operating temperature 100°C.
Dual flush, WC outlet valve operated via a push button assembly for either full or reduced flush. Cold water use only
Dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water only.
Range of WC dual flush drop valve with plastic body silicone rubber seal and NBR rubber ‘O’-ring. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of single and dual flush WC outlet valves with ABS body and EPDM seating washers. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold water use only.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.
Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.
Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.
Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Water hammer arrestor with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of 2,3 or 4 way manifolds incorporating a nickel plated brass body with non-rising spindle stop valves. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Intelligent water assist valve consisting of a motorised quarter turn shut off valve which operates in the event a leak on the supply pipe to which it is fitted. Maximum working pressure 10 bar. Cold water use only.
Range of in-line flow sensors with a plastic body, turbine and impeller case. Maximum working pressure 25.0 bar. Cold water use only.
Screw down elbow servicing valve with brass body (brushed chrome) which is intended to connect to an appliance, e.g. washing machine, dishwasher to the water supply. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of threaded fittings with either plain brass, nickel plated brass or chrome plated brass bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 99°C.
Concealed wall insulation unit with a brass body and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of isolation valves with a brass body (various surface finishes - see model) and either a quarter turn ceramic disc (PEX-230-C/P and PEX-231-C/P models) or a non-rising spindle (all other models) with various operating members (see model) and NBR ‘O’-rings. The inlet of the PEX-230-C/P and PEX-231-C/P models incorporates a stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.
MBC 12-22WM & MBC 12-28WM models are wall mounted mains supply booster sets. They are supplied with two spherical isolation valves, a spherical bypass valve and two single check valve assemblies (suitable for backflow protection against Fluid Category 2). The check valve assemblies are to be installed in accordance with the manufacturers instructions, one upstream of the pump inlet and one after the bypass valve. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet and is housed within a wall mounted cabinet. MJ3 VM & MJ3 HM models are mains supply booster sets intended to be mounted on an expansion vessel (not supplied as part of the approval). They comprise of a pump, a suction and discharge manifold with bypass arrangement, and a spherical bypass valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet. Maximum working pressure 6.0 bar. Cold water use only.
Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel (AISI 304) bodies and impellers, and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Maximum operating temperature 90°C.
Range of multistage centrifugal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum operating pressure 11.0 bar. Maximum working temperature 90°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
Range of wall mounted handshower, hose and elbow sets with metal bodies (various finishes), incorporating an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Handsets incorporate an approved check valve cartridge , however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Range of shower handsets and overhead showers with metal chromium plated bodies with. Models 20123 and 15185 are fitted with check valves at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Model 20127 is supplied with a flexable hose connection. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower arms and brackets with brass bodies (various finishes). Shower brackets incorporate single check valves cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum operating temperature 85°C.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Range of overhead shower outlets (chrome plated plastic bodies). Inlets incorporate a strainer. Maximum operating temperature 85°C
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings (280R/W model) or EPDM ‘O’-rings (286P/W model). The inlet of the 286P/W model incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted shower outlets (brass bodies), shower hoses and handsets available in various finishes (see model). The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Range of rim/deck mounted shower handsets with brass bodies (various finishes). The inlet (except for the D5A A02 60A/W model) incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the D5A A02 60A/W model incorporates a plastic flow restrictor. The products are supplied with a shower hose and a stainless steel braided EDPM lined flexible hose assembly (for connection prior to the shower hose). Maximum working temperature 60°C.
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings. Maximum operating temperature 60°C.
Range of ceiling tubes (brass bodies - various finishes) intended for use with shower heads. Maximum operating temperature 85°C.
Range of wall mounted or ceiling mounted shower arms with brass bodies (various finishes) Maximum operating temperature 90°C.
Range of wall or ceiling mounted shower arms and a wall mounted shower outlet + holder. The products incorporate a stainless steel bodies (various finishes). Maximum operating temperature 60°C.
Dolphin Blue Flexi hose range of wall outlets and brackets incorporating stainless steel bodies (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 85°C
Dolphin Blue range of handheld shower outlets with a stainless bodies (various finishes) and EPDM ‘O’-rings. The inlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C
Range of Y pattern strainers incorporating blue epoxy coated ductile iron bodies and stainless steel mesh filter. With PN16 flanges to BS EN 1092-2. Maximum working pressure 16.0 bar. Cold water use only.
Range of Y pattern strainers with a bronze body and stainless steel mesh. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.
Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 7 of 85
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.