Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headworks with single lever operating members and a self-cancelling diverter to shower outlet with Type HC device (verified by test - suitable for backflow protection against Fluid Category 3 The spout outlet incorporates an aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Two hole, single outlet (swivel) combination tap assembly (chrome plated brass) incorporating non rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headworks with dome type or single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and metal backnuts. The spout outlets incorporate a plastic aerator. The headwork is connected to the spout via interconnecting stainless steel braided, EPDM lined flexible hoses. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Expansion vessel with a stainless-steel body. Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
‘MUFA’ and ‘MUPA’ ranges of expansion vessels with epoxy coated bodies. ‘MUFA’ models have a maximum working pressure of 8.6 bar. ‘MUPA’ models have a maximum working pressure of 10.0 Bar. Cold water use only.
The products incorporate two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3), a pressure reducing valve adjustable between 1.0 bar and 3.0 bar (but pre-set at 2.5 bar for 523.815 model and 1.4 bar for the 523.816 model). The product incorporates a push type valve which allows water to flow when operated until the required pressure is achieved. There is a drain port below the push valve piston chamber. Compression connections are for use with copper pipe (manufactured to EN 1057). Maximum supply pressure 10.0 bar. Maximum operating temperature 80°C.
Range of filter heads with plastic bodies. Models with threaded connections incorporate a non-return valve (not suitable for backflow protection). Maximum working pressure 8.0 bar. Cold water use only.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of in-line water filter cartridges with plastic bodies. Maximum working pressure 8.0 bar. Cold water use only.
Range of RidgeLock™ sets consisting of Ridgeline corrugated stainless steel tubing adapter, sealing rings connected using EN 1254-2 brass fittings to achieve a compression connection. Maximum operating pressure 10 bar. Maximum operating temperature 85°C
Range of press fittings (brass bodies - various finishes) with stainless steel press (Unipress MLCP ) collars and EPDM O-rings for use with “EA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Supreme range of fittings for use with PE pipes (manufactured to EN12201-2). Supplied with a plastic pipe support liner For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube to EN 1057. For above and below ground use. Maximum working pressure: 6mm-54mm 16.0bar, 64mm-108mm 10.0bar. Maximum operating temperature 85°C
Shower wastewater heat recovery units with a copper body and twin wall separation. Maximum working pressure 10.0 Bar. Maximum operating temperature 45°C.
Range of ultrasonic water meters with brass bodies. The products incorporate a motorised butterfly valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line water meters with brass or plastic bodies. Models with a minimum length of 130mm and a maximum operating temperature of 50°C are supplied with an optional, non-return valve to be fitted by the installer (not suitable for backflow protection). Maximum working pressure 16.0 bar. The meters can be supplied with a maximum operating temperature of 50°C or 70°C.
Page 430 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.