'Sung Il & GRP ENM Tank Panel'. Light grey coloured, hot pressed GRP panel. For use with water up to 50°C.
'Pipeco Korea Tank Panel'. Light grey coloured, hot pressed GRP panel. For use with water up to 50°C.
'Sangwon GRP Water Tank Panel'. Light grey coloured, hot pressed GRP panel. For use with water up to 50°C.
'Myungjin GRP Water Tank Panel'. Light grey coloured, hot pressed GRP panel. For use with water up to 50°C.
"Reinert-Ritz PE 100 Fittings". Black coloured, extruded polyethylene fittings. For use with water up to 85°C.
'LL 8460.29'. Natural (appears white and opaque) LLDPE material manufactured by rotational moulding. For use with water up to 85°C.
'EPDM G7503'. Black coloured, injection moulded EPDM rubber material. Shore hardness 75. Tested in-radius size 1.1mm. For use with water up to 50°C.
'XR0240012'. Black coloured, compression moulded EPDM material. Shore hardness 40. Tested in-radius size 1.5mm. For use with water up to 85°C.
'EPDM 69064340'. Black coloured, injection moulded EPDM sheet material. Shore hardness 57. Tested in-radius size 0.9mm. For use with water up to 23°C.
'RE EP/50, 'RE EP/60, 'RE EP/70 & RE EP/80'. Black coloured, compression moulded EPDM materials. Shore hardness between 50 & 80. Tested in-radius size 1.0mm. For use with water up to 60°C.
'Rapidstick™ 8243’ Site applied, blue coloured anaerobic adhesive. Apply and cure as per manufacturer's instructions. 'Rapidstick™ 8243' is for use with water up to 85°C.
'Brymec PVC Solvent Cement'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions 'TDS Brymec CEMENT Rev 01' review date '27-05-2022'. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Astral PVC Gel'. Clear, transparent (un-pigmented) solvent cement, (intended to join PVC pipe and fittings). Apply as per manufacturer's instructions review date '2019-09-11'. Cure for 20 days at 7°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled combination tap assemblies (brushed stainless steel). The flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. The products are supplied with plastic backnuts and a stainless steel braided PEX lined flexible hose assembly for installation between the tap and the solenoid valve. Supplied with a plastic flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
A range of single-hole, single outlet fixed or swivel electronically controlled tap assemblies with brass bodies in various finishes (see models). Flow is controlled by a solenoid valve activated via an infra-red sensor and a ceramic cartridge with a single lever operating members controlling both the flow and temperature for all models excluding 62816, which uses a mixer to control the temperature only with a single lever operating member. The spout outlets incorporate plastic aerators. All models (excluding AZL10range) incorporate a separate approved check valve cartridge on the inlet, verified by test (suitable for backflow protection against Fluid Category 2), The inlets of all models incorporate stainless steel strainers. Maximum working pressure 5.0 bar Maximum working temperature 60°C.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of single check valve assemblies with DZR brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with either a single lever or dome type operating member (see model). The spout outlet incorporates a plastic aerator (specific models only - see model section). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks with either a single lever, cross top or dome type operating member (see model). The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a waterfall type with or without a stainless-steel mesh (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
A range of single hole single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating either ceramic cartridge or quarter turn ceramic disc headwork with a single lever, cross top or dome type operating member. The spout outlets incorporate either a plastic flow straightener or aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assembly with brass body (chrome plated), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold water inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with various operating members (see models). The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlets are a waterfall type incorporating a stainless steel strainer. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
STH Ranges of brass crimp fit fittings incorporating EPDM ‘O’-rings for use with copper pipe (manufactured to EN1057-2006). 74232, 74233, 74234, 74226, 74227, 74228, 74229 & 74231 models also incorporate a NBR gasket. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of Y type strainers with blue epoxy coated ductile iron bodies and EPDM ‘O’-rings. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Combination tap assembly (chrome plated brass), with a dome type operating member controlling the flow and temperature with a non-concussive thermostatic cartridge headwork. The spout outlet incorporates a plastic aerator. The inlets incorporate approved single check valve cartridges, however, the complete assembly has not been tested to demonstrate backflow protection. Maximum working pressure 5.0 Bar Maximum operating temperature 85°C.
Non-metallic materials and components comply with BS6920 at 85°C
Centerstore ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with cube type operating member. Temperature is controlled independently via a thermostatic cartridge with a cube type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Range of ozone cleaning units with a plastic body. The water which is discharged from these units is intended to be used for cleaning surfaces. The products incorporate a filter (cartridge and housing), pressure regulator and a stainless-steel strainer at the inlet. The flow is controlled via a metal solenoid which is operated by a switch on the front panel. Maximum working pressure 5.0 bar. Cold water use only.
Range of ion exchange water softeners (salt regenerated) for domestic use. Maximum working pressure 6.0 bar. Cold water use only.
'Relipoxy 342'. Factory applied, red coloured epoxy coating. Mix in a 3:1 weight ratio and apply in accordance with manufacturer's 'Standard Operating Procedure & Guidelines Revision 2' issue no. and date ;116/2021 15th Feb 2021'. Cure for 24 hours@30°C. For use with water up to 65°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'PPA 571 ES Blue 536'. Factory applied, blue coloured polyolefin coating. Apply as per manufacturer's instructions dated '08/2022'. Cure for 20 minutes@200°C. For use with water up to 23°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Apcoflor MFP 140 Primer and Smartcare Polyurea PW Coating'. Factory applied, grey coloured (once mixed), two-component primer (non-water contact primer) and two-component coating (water contact coating). Mix Apcoflor MFP 140 Primer in a 1:1 mix ratio and apply as per Product Data Sheet ‘Version ‘0’, dated ‘Aug.2007’. Cure for 2 hours@25°C. Then mix and apply Smartcare Polyurea PW Coating as per Product Data Sheet ‘V01’, dated ‘8/2022’. Cure for 1 minute@25°C. For use with water up to 85°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Cementitious Coating 851 Grey'. Site applied, two part, grey coloured cementitious waterproof mortar which can be applied as a one-coat or two-coat system Mix liquid (Part A) and powder (Part B) in a weight ratio of 1:3.92 and apply as per manufacturer’s instructions 'Bulletin No.851 /031/012' dated July 2021. When using as a one-coat system cure for 21 days@7°C. When using as a two-coat system cure coat one for 1 hour@7°C and cure coat two for 21 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'ELEC GRP Pipe A'. Brown coloured GRP pipe manufactured by filament winding. For use with water up to 23°C.
'CK GRP Water Tank Panel'. Light grey coloured, hot pressed GRP panel. For use with water up to 50°C.
'BÜFA®-ISO-Gelcoat 3000-H 572-9735 & Synolite 5410-P-4'. Grey coloured, unsaturated polyester gelcoat with a hand-laid unsaturated polyester resin and fibreglass laminate. Apply and cure in accordance with manufacturer's user guides 'Q-035, issue 1' & 'BUKUG 1001, issue 1' dated 19/08/2020. For use with water up to 23°C.
'509 OE/UHMWPE' hose, manufactured by mandrel wrapping and vulcanisation. Multi-layered hose comprising of a clear PE inner layer, blue coloured EPDM second layer, white coloured reinforcement third layer, blue coloured EPDM fourth layer, grey coloured helix wire fifth layer and blue coloured EPDM outer layer. For use with water up to 23°C.
`TUB05`. Extruded, dual layered hose consisting of a clear PE liner and black coloured EPDM outer layer. Shore hardness 85. For use with water up to 85°C.
'PE-BWG'. Transparent, extruded, single layer, polyethylene hose. For use with water up to 85°C.
'FlowGuard™'. Tan coloured, extruded CPVC pipe. For use with water up to 85°C.
'TCM585RE'. Red coloured chemical anchor resin supplied in a pre-weighed dual cartridge. Apply as per manufacturer's instructions dated '21.07.2021'. Cure for 48 hours@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'STRONGHOLD SH-EP3'. Red coloured chemical anchor resin supplied in a pre-weighed dual cartridge. Apply as per manufacturer's instructions dated '12/11/2020'. Cure for 48 hours@7°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 40 of 71
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.