Range of wall mounted spout outlets (brass bodies - various plated) incorporating a plastic aerator. Maximum operating temperature: 60 °C
Deck mounted spout outlet with chromium plated brass body incorporating a plastic aerator. Maximum operating temperature 60°C.
Wall mounted spout outlet, (chromium plated brass body) incorporating a plastic aerator. Maximum operating temperature 60°C.
SuperFlow MCPA, MCMA & MCUA ranges of expansion vessels. Maximum working pressures: MCPA Series = 10.0 bar, MCMA Series = 16.0 bar, MCUA Series = 25.0 bar. Maximum operating temperature 65°C.
Filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve (suitable for back flow protection against fluid category 3) and a stainless steel braided EPDM lined hose. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of brass press fittings (TH and U crimp profiles) for use with RIIFO B1 PEX/AL/PEX multilayer pipe. Maximum working pressure: 10 bar Maximum operating temperature: 95 °C
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use (sizes 12mm-54mm only. 66.7mm, 76.1mm, 88.9mm & 108mm for above ground use only) Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of PCC type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Tectite Classic and Tectite Pro ranges of copper alloy push-fit fittings The Tectite Classic range is for use with copper tube (manufactured to BS EN 1057) and PEX & Polybutylene tube (manufactured to BS 7291). The fittings are supplied with plastic inserts. The Tectite Pro range is for use with copper tube (manufactured to BS EN 1057). Maximum working pressures & operating temperatures: Tectite Classic fittings with copper pipe: 6.0 bar @ 95°C, 16.0 Bar cold water use. Tectite Classic fittings with PEX & Polybutylene 6.0 bar @ 95°C, 12.0 Bar cold water use. Tectite Pro fittings (15mm - 28mm): 6.0 bar @ 95°C, 20.0 Bar cold water use. Tectite Pro fittings (32mm - 54mm): 6.0 bar @ 95°C, 16.0 Bar cold water use.
Range of plastic ball floats. Grade C Blue float - cold water use only. Grade H Red float - for use up to 93°C.
Range of urinal flushing mechanisms, consisting of a solenoid valve controlling the flow which is actuated via an infra-red sensor. Models are either mains or battery operated and are available in a variety of enclosure options Maximum operating pressure 8 bar. Maximum operating temperature 23°C

Range of ultrasonic water meters with brass or stainless steel bodies and plastic or stainless steel transducers. The SC-F models incorporate a spherical valve operated via a motor controlled by computer software. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line water meters with stainless steel bodies Maximum working pressure 10.0 Bar. Maximum operating temperature 50.0°C.
Range of water meters with blue epoxy power coated cast iron bodies, incorporating plastic turbines, NBR ‘O’-rings and gaskets. Maximum working pressure 16.0 bar. BS6920 50°C.
Range of water meters with plastic bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meter manifolds with plastic bodies, incorporating plastic pushfit inlets and plastic pushfit outlets. The inlets incorporate a spherical ball valve. Models MB40408256DCVDM & MB40408254DCVDM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds with plastic bodies, incorporating plastic inlets and gunmetal outlets. The inlets incorporate a spherical ball valve. Models MB40408036CGDCVM & MB40408034CGDCVM incorporate two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16 bar. Cold water use only.
Range of water meter manifolds incorporated into a meter chamber. The inlet of all models incorporates an isolation valve and an approved check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection. MK7000003003 is for use with MDPE plastic pipe (manufactured to BS EN 12202-1:2011). Maximum working pressure 12.5 bar. Cold water use only.


Page 367 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.