Range of floor mounted, two-hole, single outlet (swivel) combination tap assemblies (stainless steel and brass bodies various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 70.0°C
Range of two hole, single outlet (swivel) combination tap assemblies with brass bodies (chrome plated). Incorporating non-rising spindle headworks with dome type operating members (model 922040) and ceramic disc headwork with single lever operating members (model 922075). The spout outlet incorporates a plastic flow straightener. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a lockable self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The products are supplied with a shower hose and handset, and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes - see model), incorporating quarter turn ceramic disc headworks and either single lever or dome type operating members (see model). The spout inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator (except Broadway and Niagara spout options). The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The spout junction of the Malmaison and Niagara spout options incorporates a plastic flow regulator. The product is also supplied with either a click type or pop-up waste (see model), and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes). Incorporating quarter turn ceramic disc and various operating members. The spout outlet incorporates a plastic aerator. The product is supplied with nylon braided EPDM lined flexible hose assemblies incorporating ½” captive nut end connections on both ends or at one end and M10 at the other. The hoses are intended to connect between the side body headworks and the spout junction. The product is also supplied with a pop-up waste, and a ½” BSP (F) nut and NBR washer to adapt the side valve inlet connections. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes), quarter turn ceramic disc headwork and choice of single lever or dome type operating members. The spout outlets incorporate a plastic aerator. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (chromium plated brass spout and trim set), incorporating quarter turn ceramic disc headworks with dome type operating members. The inlet of the spout incorporates a plastic flow regulator, and the spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of three-hole, single outlet, (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks with dome type operating members. The product is supplied with stainless steel braided PEX lined flexible hose assemblies for connecting the side body headworks and the spout junction. The spout inlet incorporates a plastic flow restrictor, and the spout outlet incorporates plastic aerator. The products are supplied with click type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (various finishes, see models) incorporating quarter turn ceramic disc headworks with wheel type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted spout outlets with brass bodies (chrome plated). Product is supplied with various operating members and pop up click waste. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Wall mounted waterfall, bath spout (chromium plated brass), incorporating a flow regulator on the inlet and stainless-steel strainer at the spout outlet. Maximum operating temperature 80°C. Open outlet use only
Range of wall mounted spout outlets, (brass bodies with various finishes) incorporating a plastic aerator. Maximum operating temperature: 60°C
Chlorine Dioxide dosing system consisting of various PVC pipes and fittings, a water meter and a spherical valve. The inlet incorporates a double check valve assembly (verified by test as suitable for backflow protection against Fluid Category 3). Maximum working pressure 10.0 bar. Cold water use only.
‘CD3 Series’ chlorine dioxide dosing system incorporating a single check valve positioned at the point of injection. Maximum working pressure 6.0 bar. Cold water use only.
Range of expansion vessels with EPDM membrane and stainless steel flange connections. Models VB8, VB12, VB18 & VB24 have a maximum working pressure of 16.0 bar. All other models have a maximum working pressure of 10.0 bar. Maximum operating temperature 100°C.
Range of expansion vessels with stainless steel and epoxy coated carbon steel bodies incorporating a butyl rubber membrane. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
‘Profine’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
Range of carbon block water filters and housings. Maximum working pressure 10.5 bar. Cold water use only.
Range of water filter housings with plastic heads and bodies (various colours - see model), incorporating NBR ‘O’-rings (158087/088/207/208/218/219/261 models only) or with EPDM ‘O’-rings (all other models). Big Blue for Cartridges - Maximum working pressure 6.9 bar (10” filter housings) and 6.2 bar (20” filter housings). Maximum working temp 38°C. All other models - Maximum working pressure 8.62 bar. Maximum working temp 52°C.
Carbon block filter cartridge with plastic body. The cartridge may be installed with a manifold (filter head) for use with PE tubing manufactured to BS 1972. Maximum working pressure 8.6 bar. Cold water use only
‘Multi Press Leak M.P.L’. range of fittings (pressing profile TH and U) for use with Alpex Duo XS multi-layered pipe. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of brass, chrome plated brass or DZR brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of urinal flushing mechanisms with a solenoid valve controlling the flow. The valves are controlled via an infra-red sensor. The inlet incorporates a stainless steel strainer and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
‘Aquila V4 C1’ range of water meters (brass or bronze bodies) with a plastic working chamber, flow regulator and impellor, and either NBR or EPDM ‘O’-rings. The products are supplied with loose NBR/fibre flange gaskets. Maximum working pressure 16.0 bar. Cold water use only.
A range of water meters incorporating brass or plastic bodies (See models), EDPM ‘O’-rings, plastic strainer on the inlet and a plastic impellor. Maximum working pressure 16.0 bar. Maximum working temperature 85°C (brass bodies) or cold water use only (plastic bodies)
Range of water meter assemblies which incorporating DZR brass bodies, spherical valve and pressure reducing valve (1.5 to 6.0 bar range). The products incorporate two approved, in-line single check valve cartridges, (verified by test, suitable for backflow protection against Fluid Category 3). Fitting is also supplied with a pressure guage. Maximum working pressure 10.0 bar. Cold water use only.
Range of meter boxes incorporating a plastic manifold arrangement consisting of a stop valve with non-rising spindle , check valve (however the complete assembly has not been tested to demonstrate it provides adequate backflow) and concentric meter port. Some models incorporate a drain off or blacking plug. Connections can be compression or push fit (see model). For use with PE8-0 pipe to BS EN 12201 and copper to EN 1057. Maximum working pressure 16.0 bar. Cold water use only.
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of water hammer arrestor’s incorporating brass bodies (various finishes). The 525152 model is supplied with a reinforced captive nut. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C. For products manufactured from June 2023 Maximum operating temperature 85°C
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Range of flow control valves for domestic hot water with plastic bodies and EPDM ‘O’-rings The products incorporate a motor which adjusts the flow, a flow sensor which measures the flow rate and a plastic filter on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Pressure gauge with brass body and a plastic case. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C
Range of bidet spray kits comprising of a hand set with self-closing trigger, wall bracket, flexible hose assembly, thermostatic blending valve and isolation valve. Maximum working pressure 5 bar. Maximum working temperature 60°C
‘Para Z’ range of circulating pumps with either stainless steel, bronze or plastic bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘e-SH’ range of centrifugal booster pumps with a blue polymer coated stainless steel body, stainless steel impeller and EPDM ‘O’-rings. Maximum working pressure 12.0 bar. Cold water use only.
Shower outlets incorporating chrome plated ABS bodies. Maximum operating temperature 65°C.
Range of overhead showers and shower handsets with plastic body (various finishes). Overhead shower inlets incorporate a stainless steel strainer Maximum operating temperature 60°C.
Range of shower handsets incorporating plastic bodies (various finishes), plastic flow regulators and stainless steel strainers. Maximum operating temperature 60°C.
Range of shower kits, shower outlets and shower hoses. The shower handsets and overhead shower inlets incorporate a plastic flow regulator. Maximum operating temperature 45°C.
Shower handset with a plastic body in a variety of finishes (see model). The inlet incorporates a combined EPDM washer and stainless-steel strainer, and a plastic flow regulator. Maximum operating temperature 60°C.
Shower kit consisting of a wall mounted elbow (brass body various finishes - see model), shower hose and handset. The outlet of the wall elbow incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The shower handset inlet incorporates a stainless-steel strainer and a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower outlets and shower handsets. The shower heads have a brass body and ball joint, NBR ‘O’-ring, stainless-steel strainer and silicon nozzles. The shower handset has a brass body, NBR ‘O’-rings, silicon nozzles and incorporate a plastic flow regulator on the inlet. Model ‘100274774 N200000068’ is supplied with a double interlocked hose and a single check valve cartridge (to be installed on the inlet to the hose) however the complete product has not been fully tested to demonstrate it provides backflow protection. Model ‘100274774 N200000068’ has a maximum operating temperature of 60°C. All other models have a maximum operating temperature of 85°C.
Range of wall mounted shower kits, incorporating a shower handset, shower hose and wall elbow connection. Maximum operating temperature 60°C.
Range of shower columns with chromium plated brass bodies. Maximum operating temperature 60°C.
Range of shower handsets plastic bodies (various finishes) and EPDM ‘O’-rings. All models include a button on the shower face which alters the spray pattern. The product incorporates either a plastic strainer (26 050 & 26 530) or a stainless-steel strainer and a plastic flow regulator (26 051 & 26 531) on the inlet. Maximum operating temperature 60°C.
Range of flow switches with plastic bodies. The VKX15M prefix models are supplied with an inline brass adaptor. The VKX05M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of flow switches with plastic bodies. The VK308/10/15/20/25/32/40/50M and VKS08/10/15/20/25/32/40/50M prefix models are supplied with an inline brass adaptor. The VK305/306/309M and VKS05/06/09M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Page 35 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.