Single hole, single outlet (swivel) combination tap assembly (brass body - various finishes), incorporating ceramic cartridge headworks with a single lever operating member. The spout outlet incorporates a plastic flow straightener or plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The cold only inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold inlet hose and the spout outlet incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 75.0°C
Two hole, single outlet fixed combination tap assembly (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed, combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporate a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two-hole, single outlet, (fixed) combination tap assemblies, (brass bodies – various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Model (TVW125003000xx) is supplied with a click type waste (verified by test). Maximum working pressure 10.0 Bar Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet fixed combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with dome or lever type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to a shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts and a shower hose and handset. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts and a shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a quarter turn ceramic disc headwork controlling the flow using a dome type operating member. Temperature is controlled via a thermostatic cartridge also using a dome type operating member with a manual override button, and the product also incorporates a manual diverter to shower outlet. The inlets incorporate a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two hole, single outlet, fixed combination tap assembly (chromium plated brass) incorporating ceramic disc headwork with single lever operating members and manually operated bath to shower diverter. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two-hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The inlets incorporate a stainless strainer and an approved single check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10 bar. Maximum operating temperature 65 °C
Range of two-hole, single outlet (fixed) combination tap assemblies (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with handwheel (T782001 model) or single lever operating members (all other models), and a self-cancelling diverter to shower outlet. The spout outlet of the T781001 & T782001 models incorporates a plastic aerator, all other models incorporate a plastic aerator including a stainless steel mesh. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a stainless steel mesh strainer. The product is supplied with a shower hose and handset and metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of combined bath filler and/or waste and overflow assemblies (see models) in various finishes. Open outlet use only Maximum operating temperature: 60ºC
Range of tap adaptors with chrome plated (brass or plastic) bodies. The outlet of some models incorporates a plastic flow restrictor. The side mount adaptors (except 90-001801) incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The side mount adaptors (except 90-001804) incorporate a piston type component which is intended to stop the flow to change the filter. All side mount adaptors and 90-001869 & 90-001873 Fixed Position Adaptors have a maximum working pressure of 5.0 bar. All other models are open outlet use only. Maximum operating temperature 60°C.
Range of exposed bath fillers (brass body, various finishes) incorporating a ceramic cartridge headwork, controlling both flow and temperature with a single lever operating member. The products incorporate integrated overflow and click type pop-up waste systems. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of wall mounted spout outlets (brass bodies - various finishes). The outlet incorporates a plastic aerator. Maximum operating temperature 60°C. Open outlet use only.
Range of swivel or fixed spout outlets (chromium plated brass) incorporating a plastic aerator. Open outlet use only Maximum operating temperature 60.0°C
‘Flofix’ range of expansion vessels. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of expansion vessels with fibreglass bodies and butyl diaphragms. Maximum working pressure: 8.6 Bar. Maximum operating temperature: 23 °C.
Range of filters with DZR brass bodies, stainless steel sieve. All models incorporate a drain tap and are supplied with a pressure gauge. Maximum working pressure 25.0 bar. Cold water use only.
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of CU type press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of press fittings (brass bodies - various finishes) with stainless steel press (‘TH’ profile) collars and EPDM O-rings for use with “SOUTH PRESS” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
A range of black polyethylene electrofusion fittings from DN 20 to DN 1200 for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. A range of black polyethylene butt-welded fittings from DE 20 to DE 1200 fittings for use with PE100 and PE100-RC pipes conforming to EN 12201 or ISO 4427. Maximum working pressure: 20.0 bar for SDR 9 Maximum working pressure: 16.0 bar for SDR 11 Maximum working pressure: 10.0 bar for SDR 17. For above and below ground and cold water use only.
Range of brass threaded fittings,. Above ground use only. Maximum operating pressure of 16.0 bar. Maximum operating temperature of 85°C.
Range of brass (CW617 or CW511L) press fit fittings (M-Type) for use with copper pipe manufactured to EN 1057. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
Float switch with plastic body. Maximum working pressure 1.2 bar. Maximum operating temperature 23°C.
Range of near boiling hot water dispensers with stainless steel tanks and flow is controlled via float switch. Maximum working pressure 3 Bar. Maximum operating temperature 98°C.
Range of indirect heat interface units (HIU) providing heating and instantaneous hot water. The central heating and hot water is generated via plate heat exchangers. Maximum operating pressure 10 bar (primary and DHW secondary). Maximum operating pressure 2.5 bar CH secondary Maximum operating temperature 90°C
Range of water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
SJC range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of inline water meters with brass bodies (blue or red epoxy coating). The inlet incorporates a plastic strainer. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Range of water meter manifolds with plastic bodies for use with PE80 pipe (manufactured to BS EN 12201) and copper pipe. The products incorporate a drain off valve, plastic strainer and a single check valve cartridge however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Bias chamber incorporating an EPDM diaphragm and ‘O’-ring with a brass body. Maximum working pressure 35.0 bar. Cold water use only.
Range of pressure transducers with stainless steel bodies. Maximum working pressure 10.0 Bar, 20 Bar or 40 Bar. Maximum operating temperature 99°C.
Range of booster sets consisting of two or four electronically controlled pumps, stainless steel manifold, spherical valves, expansion vessels and pressure gauge/transducers and non-return valves. Maximum operating pressure 16 bar. Maximum operating temperature 23°C.
Range of booster sets, incorporating a stainless-steel manifold system and between 2 and 5 pumps depending on model. The booster sets also incorporate spherical valves, non-return valves, pressure switches/sensors and expansion vessels. Maximum working pressure 16.0 Bar. Maximum operating temperature 25.0°C.
Shower handset with a plastic body (chrome plated), and NBR ‘O’-rings. Maximum operating temperature 65°C.
Plastic shower handsets with various finishes. Maximum operating temperature 65.0°C Open outlet use only
Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C
Shower handset with various finishes. Maximum operating temperature 65°C.
Range of shower handsets and overhead shower with various finishes. Model HS149 incorporates a stainless steel strainer washer at the inlet. Maximum operating temperature 65°C.
Page 136 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.