Rainwater harvesting back up device used to top up rainwater harvesting tanks with mains water. The device is fed by a solenoid valve and discharges via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Cold water use only.
Non-verifiable single check valve assembly with chrome plated DZR brass body. Maximum working pressure 14.0 bar. Maximum operating temperature 85ºC.
Tundish with a black metal body and a straight through pattern. The tundish complies with the requirements of an air gap to drain. Maximum operating temperature 99°C.
All pressure, single fixed, dual fixed and variable flow rate ranges of constant flow regulators. Maximum operating temperature (Grey, Natural & White) 85°C. Models UDC ll, N & N-cart have a maximum operating temperature of 60°C.
Quarter turn ceramic disc headwork (model FCN0538) and non-rising spindle headwork (model FLG0398) with brass bodies and NBR ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge assemblies with plastic bodies for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of ceramic disc diverter cartridges with flow control having plastic bodies for use in specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Non rising spindle headwork with EPDM seals and brass body. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Two way ceramic disc headwork with a plastic body and EPDM ‘O’-rings. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Ceramic cartridge headwork (sequential) incorporating a plastic body and silicone seals. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with a plastic body and NBR seals to be housed in specifically dimensioned bodies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies and EPDM ‘O’-rings. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Thermostat with a wax senor having a brass body and stainless steel guide. For insertion into specifically dimensioned bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of thermostatic mixing cartridges with plastic bodies incorporating NBR ‘O’-rings and stainless-steel filters, for insertion into specifically dimensioned bores. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Single hole single outlet (swivel) pull out spray combination tap assembly (chromium plated brass) with ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole single outlet (swivel) pull out spray combination tap assembly (chromium plated brass) with ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature with single lever type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. The product is supplied with a click type waste. Maximum working pressure 5.0 Bar. Maximum operating temperature 70°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. The product is supplied with a click type waste. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes, see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Each hose inlet incorporates an EPDM seal with a stainless steel mesh filter. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass) with a solenoid valve controlling the flow and activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies, except for /501 suffix model which is gold plated), incorporating quarter turn ceramic disc headworks or a ceramic cartridge headwork (ELAN113 & DAR113 models only), all with single lever operating members, except GE04 models which have cross top operating members. The spout outlet incorporates a plastic flow straightener, except the DAR113 model which has a plastic aerator. The DLT113 models are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Deck mounted, single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator (COB BAS C) or flow straightener (COB SMBAS C). Model COB BAS C is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating. The spout outlet incorporates a flow straightener. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Product is supplied with a click type waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (fixed) combination tap assembles with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The outlet incorporates a plastic aerator. Some models are supplied with a pop up or click type waste, see model.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated or unlaquered brass), incorporating ceramic cartridge headworks and single lever operating members. The outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with a click waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C
Range of single hole, single outlet (swivel) combination tap assemblies incorporating brass bodies (various finishes) and ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies incorporating a brass body (chrome, nickel or black finish) and ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated or brushed nickel brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Supplied with a combined isolation valve and single check valve assembly (suitable for Fluid Category 2) for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium or gold plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with a combined isolation valve and single check valve assembly (suitable for Fluid Category 2) for both inlets. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium or gold plated brass), incorporating non-rising spindle headworks with cross top operating members. The spout outlet incorporates a plastic flow straightener. Supplied with a combined isolation valve and single check valve assembly (suitable for Fluid Category 2) for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold water inlet tail incorporates approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (chromium plated), incorporating ceramic cartridge headworks and single lever operating member. The connection to flexible hose and spray outlets incorporates an approved single check valve cartridge (however, the whole product has not been fully tested to demonstrate that it provides adequate backflow protection) the outlets incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes) incorporating a ¼ turn ceramic disc headwork supplied with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies incorporating a brass body (chrome, nickel or black finish) and ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, double outlet (swivel) combination tap assemblies (chromium plated or white painted brass), incorporating quarter turn ceramic disc headworks and single lever type operating members. Outlets incorporates a plastic flow straightener. Maximum operating pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes) incorporating a quarter turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operaring temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and ceramic cartridge headwork with a single lever operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, metal, single outlet (fixed) combination tap assemblies with brass bodies (various finishes) incorporating quarter turn ceramic disc cartridge headwork with single lever operating members. The outlets incorporate a plastic aerator and the products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Page 1 of 224
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.