Range of wall mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a single sequential thermostatic cartridge controlling both flow and temperature with a single lever operating member. The spout outlets incorporate a plastic flow straightener The inlets incorporate a concentric isolation valve, stainless steel strainer and a plastic flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a single sequential thermostatic cartridge controlling both flow and temperature with a single lever operating member. The spout outlet incorporates a plastic aerator. The inlets incorporate a stainless steel strainer and a plastic flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Range of Wall mounted, four-hole, single outlet (swivel) combination tap assemblies (Various Finishes). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted or floor standing spout outlets (fixed or swivel - see model in various finishes). All models incorporate a plastic flow straightener, except for the 93-Floor Mounted Bath Filler which has a plastic aerator.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted spout outlets (fixed or swivel - see model, Various finishes) incorporating a plastic flow straightener. The products are supplied with metal backnuts.
Non-metallic materials and components comply with BS6920 at 60°C
Range of PFD press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Flowtech range of green butt welded polypropylene fittings for use with Flowtech’ PPRGF or PPR pipes. Maximum working pressure 20.0 bar. Cold water use only.
Range of fohn stainless steel (SUS304/316L) crimp fittings incorporating EPDM ‘O’-rings. For use with FOHN stainless steel pipes (SUS304/316L). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
TP range of capillary solder ring copper fittings for use with copper tube EN1057, for above ground use only. Maximum working pressure: 25.0 bar. Maximum operating temperature: 85°C.
Range of plastic compression fittings incorporating polypropylene bodies& plastic pipe liners.. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. Maximum working pressure 16 Bar Maximum operating temperature 23°C
‘Tectite 316’ range of push-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with stainless steel tube (Grade 316 manufactured to EN 10312). Maximum working pressure: Fittings 15mm to 28mm 10.0 bar. Fittings 35mm to 54mm 6.0 bar. Maximum operating temperature 90°C.
Range of compression fitting with brass and DZR brass bodies, supplied with brass compression rings. For use with copper tube (manufactured to BS EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘B’ Press XL copper crimped fittings with EPDM ‘O’-rings for use with copper pipe to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of WC dual flush drop valves operated via a two-push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of in-line water meters with plastic bodies. The inlet incorporates a plastic filter. Maximum working pressure; 16 Bar Maximum operating temperature 50°C
Range of water meter manifolds incorporating an isolation valve, housed in a meter box. For use with PE80 pipe to BS EN 12201. Maximum working pressure 16 bar. Cold water use only.
Range of differential pressure sensors with stainless steel bodies. Maximum working pressure 16 Bar. Maximum operating temperature 85°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of tap outlets with chrome plated plastic bodies. Maximum operating temperature 85°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.
Range of ‘Thermowatt’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C
`Prox’ and ‘Wave` ranges of sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C
Range of click type pop-up wastes (brass or plastic bodies - various finishes, see model).
Range of multistage pumps with brass impellers and stainless steel shaft, incorporating an approved check valve cartridge, however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only. ‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only.
Range of positive displacement diaphragm pumps with plastic bodies, EPDM ‘O’-rings and TPE diaphragm. The product incorporates an integral bypass relief valve. For use with John Guest LLDPE Pipe. Maximum working pressure 12.0 Bar. Maximum operating temperature 40.0°C.
Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C
Range of shower kits comprising of ABS bodied shower handsets and PVC multi-layer hoses incorporating EPDM ‘O’-rings. Supplied with riser rail. Available in various finishes. Maximum operating temperature 60°C
Range of wall mounted shower outlets (chrome plated or white finish). Products either incorporate a filter or a dummy unit for the insertion of a filter. Models 02-092034, 02-092039, 02-803150 & 02-092031 incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Overhead ceiling or wall mounted (depending on shower arm) shower outlet with chrome plated plastic body, EPDM o-rings and a plastic flow restrictor at the ball joint. Maximum working pressure: Open outlet. Maximum operating temperature: 60°C.
Range of overhead shower outlets, (brass bodies - various finishes. The inlets incorporate combined EPDM washers and stainless-steel strainers. Open outlet use only Maximum operating temperature 60°C
Range of wall or ceiling mounted shower outlets (chromium plated brass). All models except SH5010 incorporate a flow regulator. Open outlet use only. Maximum operating temperature 65 °C.
Range of showerheads with a plastic body (various finishes - see model) and brass connections. The A7889, A7890 and A7891 models incorporate two solenoids controlling the flow to the spray plate or a central plastic aerator. The showerhead inlet also incorporates a plastic flow regulator (except for the A7889 models). Open outlet use only. Maximum operating temperature 60.0°C
EASO range of shower head and hand showers, with ABS bodies and chromium plated finish. Open outlet use. Maximum operating temperature - 65 °C.
Range of Y pattern strainers having either brass (899ST range) or bronze (900 range) bodies and PTFE seat washers. Maximum working pressure 20.0 Bar (Model 900), Maximum working pressure 32.0 Bar (Model 899ST). Maximum operating temperature 100.0°C.
Range of pillar taps, (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork with a cross top operating member. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of stainless-steel braided TPS lined flexible hose assemblies incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves Push-fit fittings for use with: Copper Pipes manufactured in accordance with BS EN 1057 PB pipes manufactured in accordance with BS 7291-2 PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure 12.0 bar. Maximum operating temperature 65°C.
‘Qualflex Excel’ range of stainless steel over braided, PEX lined flexible hoses, incorporating EPDM or fibre washers. The products can be supplied with a range of end connections and seals. Some models also incorporate integral isolation valves. Push-fit fittings for use for with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar. Maximum operating temperature: 65°C.
Inlet hose consisting of a EPDM inner hose layer and corrugated outer cover. The hose is fitted with an integral device consisting of a water sensitive material which expands when in contact with water. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of stainless steel or nylon braided EPDM lined flexible hose assemblies with various brass end connections. Compression connection to be used with copper pipe EN1057. Maximum working pressure 10 Bar. Maximum operating temperature 70°C.
Nylon and stainless-steel braided EPDM lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C
Range of stainless steel braided hoses with EPDM liner and NBR or fibre gaskets. DN13 and DN19 Maximum working pressure 10 bar. Maximum operating temperature 65°C. DN25 Maximum working pressure 10 bar. Cold water use only.
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Range of stainless steel or brass double interlocking, TPS lined flexible hose assemblies (various finishes) incorporating EPDM gaskets. Maximum operating temperature 60°C. Open Outlet Use Only
Ultraflow ranges of Direct, Indirect, Solar Single, Solar Twin, Slim Direct and Slim Indirect stainless steel insulated unvented hot water storage cylinders with external expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar and 90°C, an inlet control group consisting of a pressure reducing valve adjustable between 2.7 and 3.3 bar, an expansion relief valve (SRV) set at 6.0 bar, a strainer and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) also supplied with a tundish. Maximum supply pressure to the inlet control group 10.0 bar. Maximum working pressures - Primary circuit 6.0 bar, Secondary circuit 5.5 bar. Maximum operating temperature 65˚C.
Page 61 of 86
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.