Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.
Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C
Range of direct gas fired condensing storage water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 80°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Range of wall mounted combination boilers providing domestic hot water (DHW) via a plate heat exchanger and pressurised central heating (CH) system. Incorporating a pressure relief valve set at 3.0 bar and expansion vessel. Supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressure Primary circuit (CH) 2.5Bar, Secondary circuit (DHW) 10.0 Bar Maximum operating temperature 90.0°C
Octave range of water meters with blue epoxy coated cast iron or plastic bodies (see models). Maximum working pressure 16.0 Bar. Maximum operating temperature 50.0°C
‘Helvatron H2O’ range of ultrasonic water meters with brass bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Arrangement of PVC-U pipe and fittings for use with the Orca System. Maximum working pressure 9.0 bar. Cold water use only.
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower hose. Model (5840/MBG/W) is supplied with a single lever trim set. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
‘Monsoon Standard’ range of single and twin ended shower booster pumps with brass bodies, brass impellers, EPDM seals and NBR ‘O’-rings. The inlet(s) of the pump body incorporate(s) a plastic strainer. Models with push fit connections include an integral isolation valve. Pushfit connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.
Range of multistage pumps with stainless steel bodies, impellers, shaft and outer sleeve. SC family models are submersible pumps. SCD family models are surface pumps only. SCDS family models can be used either as a surface pump or as a submersible pump. SCD/SCDS models: Maximum working pressure 10.0 bar. SC models: Open outlet use only. Cold water use only.
Range of overhead shower outlets with chromium plated brass bodies. For installation with specific rough kit sets, incorporating stainless steel strainers and flow regulators in the inlet. Maximum operating temperature 80.0°C For open outlet use
Concealed, wall mounted elbow fitting with a brass body incorporating EDPM `O`-rings. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 70.0°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of shower outlets with chrome plated brass bodies incorporating a single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 28450410 is a wall elbow for use with the shower sets and incorporates a check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature: 60.0°C
Range of shower outlets, (brass bodies - various finishes), incorporating ball joints, EPDM ‘O’-rings and NBR rubber seals. Maximum operating temperature 60°C
Range of wall or ceiling mounted shower outlets with plastic bodies (various finishes) and brass shower arms (various finishes, incorporating EPDM O-rings and plastic flow regulators. Maximum operating temperature 60°C.
Range of chrome plated plastic bodied or brass bodied (28 489 xxx model) overhead shower outlets. The 27 405 xxx model is supplied with a ceiling mounted shower arm and the 27 424 xxx models with a wall mounted shower arm, both are chromium plated brass. All shower outlets incorporate a combined EPDM washer and plastic strainer on the inlet. Maximum operating temperature 70°C.
Range of shower kits, comprising of (chrome or matte black) shower handsets, shower hoses and riser rail assemblies. The shower handsets incorporate plastic flow regulators. Maximum operating temperature: 60°C.
Range of showers handsets with plastic bodies. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower heads with plastic bodies. with stainless-steel strainer plastic flow regulator on the inlet.
Non-metallic materials and components comply with BS6920 at 60°C
Range of electronic pressure switches housed in a plastic body with a ceramic sensor and NBR gaskets and/or ‘O’-rings. The 1091203260 & G0912026 models incorporate a spring-loaded plastic flow restrictor. Maximum working pressure 12.0 bar. Cold water only.
Range of drain taps with brass body and rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of bath pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks and cross top operating members. The spout outlet incorporates a plastic aerator and is supplied with metal backnuts. Maximum working pressure 10 Bar. Maximum operating temperature 60°C.
Range of deck mounted, fixed or swivel (model 909101 only), self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operating members (see models). The outlets incorporate a plastic flow straightener or aerator. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, fixed, self-closing basin pillar taps (chromium plated brass), incorporating a spring-loaded headwork controlling the flow with either dome type or lever operated operating members (see models). The outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of PE lined, nylon braided (black or grey) flexible hose assemblies. The hoses are available with a variety of end connections with different finishes (see model). Maximum operating temperature 85°C. Open outlet use only.
Range of stainless steel, stainless steel with nylon or nylon braided, EPDM lined hose assemblies. Some models incorporate servicing valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). Maximum working pressure 10 Bar. Maximum operating temperature 85°C
Range of Indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 90˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check cartridge, verified by test (suitable for backflow protection against fluid category 2) an expansion vessel and tundish. Maximum working pressure: Secondary: 4.0 Bar Primary: 3.0 Maximum operating temperature 99.0°C
Range of wall mounted, manually operated, blending valves, incorporating a ceramic cartridge headwork and single lever operating member with a self-cancelling diverter. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted, bar shower mixers, (chrome plated brass bodies) incorporating a thermostatic cartridge controlling the temperature with either dome or cubed type operating members that incorporate manual override buttons and quarter turn ceramic disc headworks controlling the flow with dome or cubed type operating members. The inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure - 6 Bar. Maximum operating temperature - 65°C.
‘Rada’ electronically controlled thermostatic blending valve, with a stainless-steel body, EPDM ‘o’ rings and seals. Maximum working pressure; 13.8 Bar. Maximum operating temperature 85°C.
Range of wall mounted thermostatic shower valves, (brass bodies - various finishes) incorporating two push button headworks controlling the flow to the hand shower or overhead shower outlet. The temperature is controlled independently via a thermostatic cartridge with single lever operating member which incorporates a manual override button. The inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of wall mounted, concealed, thermostatic shower valves (brass bodied - chrome plated trim set), flow is controlled via a solenoid valve that is activated by an infrared sensor or touch sensor. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 8.0 Bar. Maximum operating temperature 65.0°C
Range of wall mounted, concealed, thermostatic shower blending valves with brass bodies and polished stainless-steel trim/faceplates. Flow is controlled by a single sequential headwork with a single lever operating member. The inlets of the H96BOX each incorporates a isolation valve and a plastic strainer. The 9639SRV and 9632SRV models incorporate a plastic strainer and a plastic flow regulator on each inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, exposed, thermostatic bar type shower mixing valve (brass body, various finishes - see model). The product incorporates a 2-way ceramic disc diverter headwork with a single lever operating member controlling the flow to either shower outlet. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member and a manual override button. The product is supplied with a shower riser, overhead shower, shower hose and shower handset. The inlets incorporate a combined washer and stainless-steel strainer, as well as an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending valves, (brass bodies – chrome plated plastic trim sets) incorporating single sequential headworks controlling both flow and temperature. The inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate back flow protection. Model (31997W is valve only) all other models are supplied with shower hose, handset & riser rail assembly. Maximum operating pressure 5 bar. Maximum operating temperature 50°C
ange of wall mounted thermostatic shower valves, (brass bodies – chrome plated plastic trim sets). Incorporating a sequential headwork controlling flow and temperature. Model (31983W-CP) direction of flow is controlled independently with a single lever operating member that diverters from shower to shower. Model (31982W-CP) is supplied with a shower hose, handset & riser rail assembly. Model (31983W-CP) is supplied with a shower hose, handset, over head shower & riser rail assembly. Maximum operating pressure 5 bar. Maximum operating temperature 50°C
Range of pilot operated pressure reducing valves with epoxy coated ductile iron body (either blue or red/brown). The valve has an adjustable pressure reducing facility controlled via a pilot valve, with auxiliary components including stainless steel tubing and fittings, nickel plated brass spherical valves and a ‘Y’-pattern strainer. DN600-DN1400 sizes also incorporate a needle valve and a swing gate valve. Maximum inlet supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range of 1.0 – 7.2 bar. Maximum operating temperature 65°C.
Range of in-line lever operated spherical valves with stainless steel bodies, stainless steel ball and PTFE seats. Maximum working pressure 30 Bar. Maximum operating temperature 85 °C.
Range of lever, handle or square operated (see models) spherical valves with brass bodies, incorporating PTFE seats and a brass ball with a red coating. Maximum working pressure 40.0 Bar Maximum operating temperature 95.0°C
Range of spherical valves incorporating nickel plated (brass bodies with chrome plated brass ball and operated via lever, handle or screwdriver slot. For use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of lever or butterfly operated spherical valves with brass or nickel-plated brass or DZR brass bodies models Models M69150000LPDZR & M69220000FBDZR . Incorporating brass or nickel-plated brass or DZR brass ball. For use with copper pipe BS EN 1057. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
Page 60 of 82
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.