Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of waste water heat recovery systems incorporating a twin wall copper coil (7773414 models) or stainless steel (7771332 models). Maximum working pressure 10.0 bar. Cold water use only.
Gas fired water heaters incorporating a heat exchanger and flow sensor. The inlet incorporates a plastic strainer. The products are supplied with isolation valves for installation on the cold inlet and hot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60˚C
Range of gas fired condensing water heaters incorporating stainless steel storage tank, buffer tank and strainer on the cold water inlet. Maximum working pressure 10.0 Bar, maximum working temperature 83˚C.
Range of gas fired water heaters incorporating stainless steel strainers on the inlets. Maximum working pressure 10.0 Bar Maximum working temperature 85˚C
LCB700 range of internal and external oil-fired condensing combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). Operating parameters: Primary (space heating) circuit: Maximum working pressure 2.5 Bar. Maximum operating temperature 105°C. Secondary (DHW) circuit: Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of heat interface units (HIU) with either twin or single stainless steel copper brazed plate heat exchangers (depending on model) providing heating and hot water (twin unit) hot water only, or heating only. The hot water is generated via a plate heat exchanger. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product incorporates a CAb backflow prevention device (suitable for backflow protection against Fluid Category 3) for filling the heating circuit. The inlet and outlet of all circuits incorporate a lever operated spherical valve. Maximum working pressures and operating temperatures: Primary (district heating): 10.0 bar and 85˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 80˚C.
Range of ice making machines which incorporate a solenoid valve to control the flow. Maximum working pressure 5.0 bar. Cold water use only.
Range of commercial ice making machines which incorporate a solenoid valve controlling the flow. Maximum working pressure 7.8 bar. Cold water use only.
Range of water meters with plastic or brass bodies. The inlets incorporate a plastic strainer. Maximum working pressure 16.0 bar. RTKD range has a maximum operating temperature of 50°C. RTKD-L range has a maximum operating temperature of 30°C.
Ultrasonic water meter with a blue epoxy coated ductile iron body and EPDM ‘O’ rings. Maximum working pressure 16.0 Bar. Maximum operating temperature 50°C.
Range of rotating piston, volumetric in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Cold water use only.
Wallgate CWC Series 250 WC pan with direct acting flush valve and DFKIT03 air break (DC device). WC flushing mechanism has a solenoid valve controlling the flow, the valves are operated via an infrared sensor or a piezo control button, this mechanism is fitted with a DC pipe interrupter, the DFKIT03 is fitted with a flow regulator. Maximum working pressure 2.0 bar. Cold water use only.
Shower kit, intended for use with ovens, incorporating a triple layered hose on a reel and a push-button operated shower handset. The inlet of the shower handset incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 4.0 bar. Cold water use only.
Range of circulation valves and flow sensor valves with EPDM seals and O-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 90ºC.
Range of concealed bathroom boxes with extractable shower hoses. The inlet attached to the concealed box incorporates an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet of the shower hose also includes a stainless steel strainer. Maximum operating temperature 60°C.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: DST-P140 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Vola 200M separate outlet socket with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of circulating pumps, with plastic or stainless steel bodies (cast EN 1.4308 or plate EN 1.4301) and a plastic impeller. Maximum working pressure 10.0 bar (stainless steel bodied pumps), 3.0 bar (plastic bodied pumps). Maximum operating temperature 95°C.
Range of single stage circulating pumps with plastic impellers and stainless steel housing, (red or black external coating, and from July 2023 a yellow external coating on the 1½" model with 130mm port length). From December 2023 the UPS25 prefix models can be supplied with EPDM inlet/outlet gaskets and the UPS32 prefix models can be supplied with fibre/NBR inlet/outlet gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C (s/steel plate EN 1.4301/1.4401 models) or 99°C (s/steel cast EN 1.4308 models).
Range of wall or ceiling mounted overhead shower outlets (chromium plated brass) and shower arm. Maximum operating temperature 60°C.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only. From July 2023 can also be supplied without the check valve at the inlet.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower outlets with chromium plated bodies with check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum operating temperature 70°C. Open outlet use only.
Range of shower handsets and shower heads with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Range of inline strainers incorporating DZR brass bodies and a stainless steel mesh. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of flow switches with brass bodies incorporating EPDM ‘O’-rings, acting as a leak detection system that actuates an integral spherical valve to shut off the water supply. The inlet incorporates a stainless steel strainer. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 30°C.
Range of pillar taps with brass bodies (chromium plated) incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chrome plated brass) with quarter turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener or aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating pressure 85°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps with brass bodies (various finishes) incorporating non-rising spindle headworks using either dome type or cross top operating members. Spout outlets incorporate plastic flow straighteners. The products are also supplied with metal back nuts. Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Self-closing basin tap assembly (chromium plated brass) incorporating spring loaded headwork and dome type operating members. The inlet incorporates a plastic flow restrictor and the spout outlet incorporates a plastic flow straightener. The product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of stainless-steel braided EPDM lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of multi-layer shower hoses with a PVC inner hose, supplied with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Advance Appliance ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.
Range of 2, 3 and 4 port manifold assemblies with either DRZ brass or brushed chrome plated brass bodies incorporating screw down isolation valves with dome type operating members. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of 2, 3 and 4 port manifold assemblies with brass bodies (brushed chrome finish). The products are supplied with isolation valves. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
502 series of automatic air venting valves with brass bodies, plastic float and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 115°C. Model added September 2021 (501500) has a maximum operating temperature of 120°C. All other models have a maximum operating temperature of 115°C.
Range of deck mounted, manually operated blending valves with brass bodies (various finishes), incorporating ceramic cartridge headworks with either single lever (6900XX/METAL only) or dome type (all other models). The product is supplied with a shower hose and handset. Maximum working pressure 3.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed shower valves (chromium plated brass) incorporating a ceramic cartridge headwork with single lever operating member. The shower outlet incorporates an approved single check valve cartridge however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection. Products are supplied with overhead shower outlet and shower hose. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted manually operated, concealed blending valves (cast brass body) with a ceramic cartridge headwork controlling both flow and temperature with as single lever operating member and a manual diverter to shower outlets with a single lever operating member. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Wall mounted thermostatic bar type shower valve incorporating a ceramic cartridge headwork, with single lever operating member, which controls and diverts the flow between the two shower outlets. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member which incorporates a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
3 outlet concealed wall mounted thermostatic mixer valve incorporating a quarter turn ceramic disc headwork controlling the flow. The temperature is controlled independently via a thermostatic cartridge. Inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65.0°C
Range of concealed thermostatic mixing valves with brass bodies and exposed trim sets (various finishes). Incorporating a ceramic disc headwork controlling and diverting the flow between shower outlets and an independent thermostatic cartridge controlling the temperature. The inlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic shower valves with brass bodies and various trim plates (see model). V-BOX Therm. 2 way Shower Mixers incorporate a 2-way ceramic disc diverters/headworks (2 on, 1 off) controlling the flow with a single lever operating member. V-BOX Therm. 1 way Shower Mixers incorporate a quarter turn ceramic disc headwork controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member which incorporates a manual override button. Each inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Non-metallic materials and components comply with BS6920 at 60°C
Thermostatic mixing valve with a brass body within a plastic outer case. Flow is controlled via an electronically operated ceramic cartridge via a motor. Temperature is controlled via a temperature sensor that electronically adjusts the ceramic cartridge via a motor. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted bar type thermostatic shower valves (chromium plated brass) incorporating a 2-way ceramic disc diverter headwork controlling the flow between an overhead shower outlet or a shower handset with dome or cube type operating members. The temperature is controlled independently via a thermostatic cartridge with dome or cube type operating member that also incorporates a manual override button. Both inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of butterfly valves with a plastic body, PVDF disc & EPDM sealing ring. The closing mechanism is controlled by a single lever operating member. Maximum working pressure 16.0 Bar. Maximum operating temperature 80°C. Maximum working pressure: (DN200 - 250): 10.0 bar (DN300): - 6.0 bar
Page 28 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.