Range of single-hole, single outlet, fixed combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with level operating members. The spout outlets incorporate plastic aerators. The products are supplied with click wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass bodies), incorporating a ceramic cartridge headwork and single lever operating members. The spout outlet is a waterfall type. The products are supplied with a click type pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 85ºC.
Range of single hole, single outlet, fixed combination tap assembly, (chrome plated brass bodies) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate aerators and plastic flow straighteners. The products are supplied with a click type pop-up waste. Maximum working pressure 16 bar. Maximum operating temperature 60°C
Range of single-hole, single outlet, (swivel), combination tap assemblies (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members. Models (ASP2/CH, ASPQ2/CH & SLD2CH) incorporate ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature - see models.
Single hole, single outlet, swivel combination tap assembly with brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet, swivel combination tap assemblies (brass bodies, various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The vented models are supplied with a stainless steel braided PEX lined flexible hose assembly incorporating a ½" captive nut end connection, which provides main cold water to a venturi device which is part of a command centre (not supplied). The Arc vented models are supplied with a DZR brass tee piece, two DZR brass adaptors, two stainless-steel strainers (each combined with an EPDM washer) and a plastic flow restrictor, for installation prior to the cold inlet hose. The Arc and Cube mains models are supplied with two DZR brass adaptors and two stainless-steel strainers (each combined with an EPDM washer), for installation on each inlet hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Two hole, single outlet (fixed) combination tap assembly (chromium plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator and the product is supplied with metal backnuts. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of wall mounted two-hole, single outlet, (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with dome or cube type operating members and a manual diverter located on the spout to a shower handset or spout Temperature is controlled by a thermostatic cartridge with a dome or cubed type operating member with an override button. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Deck mounted two-hole, single outlet (fixed) combination tap assembly (chromium plated brass) with a self-cancelling diverter to a shower outlet. The product incorporates a ¼ turn ceramic disc headwork and single lever operating members. The spout outlet incorporates a plastic aerator. The products are supplied with metal backnuts, stainless steel braided PVC lined shower hose and chromium plated shower handset. Maximum operating pressure 5 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted, two-hole, single outlet (fixed) combination tap assembly, (brass body - various finishes), incorporating quarter turn ceramic disc headworks with various operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener, and the shower outlet connection incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models are supplied with a shower hose and handset. The shower handset incorporates a plastic flow restrictor on the inlet. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (matte black or chrome plated finish). Incorporating quarter turn ceramic disc headworks, single lever operating members and a manual diverter to shower outlet. Products are supplied with shower hose and handset. Product incorporates approved check valve cartridges however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of two-hole, single outlet (fixed) combination tap assemblies, (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic aerator or open outlet. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet (fixed) combination tap assemblies, (brass bodies – various finishes) incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Two-hole, single outlet (fixed) combination tap assemblies, (brass bodies, various finishes) incorporating quarter turn ceramic disc headworks with dome operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with metal back nuts. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with cross top operating members and a manual diverter to shower outlet. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
Range of two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to shower outlet. The spout outlets incorporate plastic aerators. The products are supplied with metal back nuts. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 65°C
A range of wall mounted two-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes see models), incorporating quarter turn ceramic disc headworks, dome type operating members and self-cancelling diverter to shower outlets. The temperature is controlled independently via thermostatic cartridges with dome type operating members. Both operating members incorporate a manual override. Spout outlet incorporates a plastic aerator. Products are supplied with shower hose, shower handset and overhead shower. The inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Two-hole, single outlet (fixed) combination tap assembly, (brass body - various finishes), incorporating quarter turn ceramic disc headworks with various operating members, and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The inlet to the shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models are supplied with a shower hose and handset. The shower handset incorporates a plastic flow restrictor on the inlet. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a lockable self-cancelling diverter to shower outlet. The flow is controlled by a quarter turn ceramic disc headwork with a dome operating member and the temperature is controlled independently via a thermostatic cartridge with a dome operating member and manual override button. Both inlets incorporate stainless-steel strainers and a single check valve cartridge (however, the complete product has not been fully tested to demonstrate it provides backflow protection). The spout outlet incorporates plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with either single lever (16 535 xx0) or cross top (16 536 xx0) operating members. The spout outlet incorporates a plastic aerator. The product is supplied with a lever type operated pop-up waste. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 70°C
Range of three-hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes) incorporating quarter turn ceramic disc headwork with single lever operating members. Spouts incorporate plastic aerators. The products are supplied with stainless steel PEX lined flexible connecting hoses incorporating BSP female end connections. Some models supplied with a lever operated pop-up waste (20713831-00, 20713831-69, 20713832-00 & 20713832-69) and all models are supplied with metal backnuts. . Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of bath fillers, waste and overflow assemblies (chromium plated brass and plastic body), incorporating a click type pop-up waste. The inlet of model 58 129 003 Hansgrohe Exafill incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Combined bath filler and overflow waste assembly with plastic bodies (various finishes).The outlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product incorporates click type pop-up waste (verified by test). Open outlet use only. For domestic use IRN R160 applies. For non-domestic use IRN R090 applies. Maximum operating temperature 45°C.
Wall mounted spout assembly, (brass body – various finishes), incorporating a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall-mounted spout outlet consisting of a brass body with various finishes, plastic aerator and EPDM ‘O’ rings. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
‘Blutron’ plastic bodied filter head incorporating EPDM ‘O’-rings for use with filter cartridges (not supplied).For use with LLDPE tube (manufactured to DIN 8072). All models can be specified with or without an integral bracket. Maximum working pressure 6.0 bar. Cold water use only.
Range on inline filter cartridges incorporating plastic bodies. The filter media varies between models and includes active carbon, silver impregnated active carbon, silver carbon block & weak/strong cationic resin. Maximum working pressure 6.0 bar. Cold water use only.
Range on inline filter cartridges incorporating plastic bodies. The filter media varies between models and includes active carbon, silver impregnated active carbon, silver carbon block & weak/strong cationic resin. Maximum working pressure 6.0 bar. Cold water use only.
Range of JG Twist & Lock Speedfit push-fit fittings for use with JG Speedfit Layflat Polybutylene Barrier Pipe (BPB Pipe to BS EN 7291-2:2010), 'BPEX' Barrier Pipe.(BPEX Pipe to BS EN 7291-3:2010) and Copper Pipe to BS EN1057:2006 Max working pressure & operating temperature: 12.5 Bar at 20°C 6.0 Bar at 83°C
‘Atlas’ range of green fusion welded polypropylene fittings for use with ‘Atlas’ PPRGF or PPR pipes. Maximum working pressure 20.0 bar. Cold water use only.
Range of brass compression fittings for use with copper pipe only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
‘Trustlene’ range of electrofusion and spigot fittings, with PE100 or brass bodies, for use with SDR11 PE100 pipe (manufactured to IS 4984: 2016). For use above and below ground. Maximum working pressure 16.0 bar. Cold water use only.
Range of Effast PVC-u solvent welded and/or threaded fittings for use with PVC-u pipe manufactured to (EN1452-2). Maximum working pressure 16.0 bar. Cold water use only.
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
‘G5 B’ & ‘G5 BA’ ranges of command centres that provide instant near boiling (filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
SATK Series 22 range of wall-mounted direct heat interface units providing heating and instantaneous hot water. The hot water is generated via a plate heat exchanger. Maximum working pressure of all water circuits (secondary hot water, primary and space heating) 10.0 bar. Maximum operating temperature 90°C.
‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of water meters with brass bodies. The inlets incorporate a plastic filter. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 50°C
Range of in-line water meters with brass bodies. The inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of water meters with plastic bodies. Maximum working pressure 16 Bar.
Non-metallic materials and components comply with BS6920 at 50°C
Water meter with a plastic body and working chamber incorporating and EPDM ‘O’-ring, NBR ‘O’-ring and seal. Maximum working pressure 16.0 bar. Cold Water use only.
Range of water meters with brass bodies, with integral plastic strainer and EPDM ‘O’- rings. The product is supplied with an optional combined plastic washer and stainless-steel strainer for installation on the inlet. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with plastic or brass bodies, incorporating EPDM O-rings. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 50°C
ALTAIR V5 Type A3 range of inline and concentric water meters. Inline models have brass or plastic bodies, concentric models are available with DZR brass or plastic bodies, the MCI model has a plastic body. Incorporates a plastic strainer. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with blue epoxy power coated cast iron bodies, incorporating plastic turbines, NBR ‘O’-rings and gaskets. Maximum working pressure 16.0 bar. BS6920 50°C.
Range of water meters with epoxy coated cast iron bodies. Maximum working pressure 16.0 bar. Cold water use only.
Pentobox range of water meter manifolds with plastic bodies and an integral spherical valve on the inlet. The models incorporate a non-return valve, (not suitable for backflow protection). Compression models are for use with metric and imperial PE80 pipe (manufactured to BS EN 12201). Maximum working pressure 16.0 bar. Cold water use only.
Magnetic non-return valve with a brass body and EPDM seals. Maximum working pressure 16.0 Bar. Cold water use only.
Range of hose assemblies. Models B0301-148036-000 & B0301-148038-000 comprise of a spherical valve, stainless-steel braided EPDM lined flexible hose and double check valve assembly (suitable for backflow protection against fluid category 3). Model B0301-148037-000 comprises of a double check valve assembly (suitable for backflow protection against fluid category 3), stainless-steel braided EPDM lined flexible hose and ‘T’ type spherical valve. Maximum working pressure 10.0 bar. Cold water use only.
Page 87 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.