Range of single hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating a ceramic cartridge headwork and single lever operating members however model 4E6004 – is fitted with a non rising spindle headwork and dome type operating members. The spout outlet incorporates a plastic flow straightener on models: 4E6002, 4E6003, 4E6004 or flow straightener and aerator kit on models: 4E6011, 4E6012 & 4E6013, and some models are supplied with a click waste. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a quarter turn ceramic disc headworks with cross top operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet incorporates an approved check valve cartridge, verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes - see model), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. The inlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a click type pop-up waste. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headwork and single lever operating member. The spout outlets incorporate a plastic aerator. The inlet hose incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass body, various finishes - see model), incorporating quarter turn ceramic disc headworks with single lever, cross top or wheel operating members. The spout outlet incorporates a plastic aerator and the products are supplied with a click type pop-up waste. Maximum operating pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic disc headwork with single lever operating members. The spout outlets incorporate plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The cold water inlet incorporate an approved check valve cartridge, verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating a quarter turn ceramic disc headworks with either single lever, dome or cross-top operating members. The spout outlets incorporate plastic aerators or flow straighteners with a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) incorporating quarter turn ceramic disk headworks with single lever operating members. The cold water inlets is supplied with a chrome plated brass adapter incorporating an approved check valve cartridge which has been verified by test (as suitable for backflow protection against Fluid Category 2) The spout outlets incorporate plastic aerators. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies. Incorporating a quarter turn ceramic disc headworks with either single lever, dome or cross-top operating members. The spout outlets incorporate plastic aerators or flow straighteners with a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes). Incorporating a quarter turn ceramic disc headworks with either single lever, dome or cross-top operating members. The spout outlets incorporate plastic aerators or flow straighteners with a stainless steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. This product also incorporates an additional spring-loaded quarter turn ceramic disc headwork with a single lever operating member for filtered cold water discharged from the spout outlet. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Two-hole, single outlet (fixed) combination tap assembly, (chrome plated brass body) incorporating quarter turn ceramic disc headworks with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C..
Range of wall mounted two hole, single outlet, (fixed) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chrome plated brass). Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate either a plastic flow straightener or aerator depending on model. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a single sequential headwork controlling both flow and temperature using a single lever operating member. Inlets incorporate an isolation valve, stainless steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. SF1134CP model is supplied with a removable spout. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature using a single lever operating member. Inlets incorporate an isolation valve, stainless steel strainers and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. SF1132CP is supplied with a removable spout. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headwork with single lever operating member. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated or matt black finished brass), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets of models 62315-5001, 62901-5001, 62907-5001 incorporate a plastic flow straightener. The inlet of model 62913-5001 incorporates a plastic flow restrictor. The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headwork with single lever or dome type operating members. The spout outlet of model 60828-5301 incorporates a plastic flow straightener. The spout outlet of models 62277-5001 & 62277-5101 incorporates a plastic aerator. Model 62277-5101 is supplied with metal backnuts. Models 60828-5301 & 62277-5001 are supplied with plastic backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks with single lever Operating members and manual diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc or ceramic cartridge headworks various operating members (see models) and a manual diverter to shower outlet. The spout outlet either incorporates a plastic flow straightener, plastic aerator or an open outlet (see models). The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, metal, single outlet (fixed) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a manual diverter to the shower outlet. The products are supplied with a shower hose, shower handset and metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic mixing valves (chrome plated brass bodies), incorporating ceramic disc diverter headworks controlling the flow from spout outlet to shower outlet using either dome or single lever operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button either dome or single lever operating members. The spout outlet incorporates a flow straightener or aerator. The inlets incorporate stainless steel strainers and approved single check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with hose and handset. Maximum working pressure 10.0 bar Maximum operating temperature 60°C
Floor mounted, two hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with cross top operating members and a manually operated diverter to shower outlet. The product is supplied with a shower hose and handset. The shower handset inlet incorporates a plastic flow restrictor. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The4E6008 and 4E6017 models are also supplied with an optional plastic aerator. The products are supplied with a shower hose and handset and metal back nuts. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Two-hole, single outlet (fixed) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disc headworks with single lever operating members and a self-cancelling diverter to the shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with a shower hose and handset and metal back nuts. Models VAL2 BSM E6 C CD & VAL2 BSM E8 C CD come supplied with flow restrictors. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
Range of wall mounted two-hole, single outlet (fixed), combination tap assemblies incorporating brass bodies (various finishes), ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet. The spout outlets incorporate plastic aerators. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two hole, single outlet (swivel) combination tap assembly with brass bodies (chrome plated), incorporating quarter turn ceramic disc headworks and single lever operating members (model 740910) or non-rising spindle headworks with dome type operating member (model 546840). The spout outlet incorporates a plastic aerator or plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members and lockable diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product includes a shower hose, shower handset and is supplied with metal backnuts. Model PAX106 is also supplied with a flow regulator. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of three hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating. The spout outlet incorporates an aerator or a flow straightener. Product supplied with stainless steel braided EPDM lined flexible connection hoses. Maximum working pressure 3.5 Bar. Maximum operating temperature 60°C.
Four-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter to shower outlet. The spout incorporates a flow restrictor on the inlet and a plastic aerator at the outlet. The product is supplied with a shower hose, handset and metal backnuts. The inlets of the handset and diverter incorporate an approved single check valve cartridge, verified by test, suitable for backflow to fluid category 2. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Five-hole, single outlet, fixed combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks with dome type operating members. The spout inlet has a plastic flow regulator the spout outlet incorporates a plastic aerator. The self-cancelling diverter, shower outlet and the shower handset incorporate an approved check valve cartridge, verified by test, suitable for backflow to fluid category 2. The product is supplied with metal back nuts, shower hose and shower handset. Maximum working pressure 10 bar. Maximum working temperature 60°C
Range of floor standing bath mixers (chromium plated brass) incorporating a ceramic cartridge diverter headwork with dome type or single lever (F3034/6.WR model only) operating members. The spout outlet incorporates a plastic flow straightener. The products are supplied with a shower hose and handset and a floor mounting kit. Maximum working pressure 5.0 bar. Maximum working temperature 60°C.
Range of deck mounted spout outlets incorporating chrome plated brass body (model F2158.WR) or a stainless-steel body (model F2943INOX.WR). The outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted spout with a brass body (chrome plated). The spout outlet incorporates a TPE gasket. Maximum operating temperature 60°C.
Range of wall mounted spout outlets incorporating chrome plated brass bodies (models CPHSP2929, ZCPHSP2929, CPHMA2418 & ZCPHMA2418) or a stainless-steel body (models CPHSP2944SS & ZCPHSP2944SS). The outlets incorporate a plastic flow straightener (models CPHSP2929 & ZCPHSP2929) or a plastic aerator (models CPHMA2418, ZCPHMA2418, CPHSP2944SS & ZCPHSP2944SS) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted spout outlets incorporating chrome plated brass body (models CPHSP2158 & ZCPHSP2158) or a stainless-steel body (models CPHSP2943SS & ZCPHSP2943SS). The outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted spout outlet (chromium plated brass) incorporating a plastic aerator. Maximum operating temperature 60°C, open outlet use only.
Range of horizontal or vertical expansion vessels with an EPDM membrane. Maximum working pressure 10.0 or 16.0 bar (please refer to model). Maximum operating temperature 100°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper press fittings with EPDM ‘O’-rings for use with EN1057 copper tube. The joints are achieved by means of a press tool. For above and below ground use. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Instantor range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Wavin range of Tigris K1 (plastic bodies) and M1 (brass bodies) press-fit fittings for use with Tigris PEX/AL/PE HD (50mm & 63mm) and Tigris PERT/AL/PERT WT (75mm) barrier pipes. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
Range of solder ring copper fittings for use with copper tube to EN 1057. The HLSRDPMFWT and HLSRDPMFZT models incorporate a captive nut on one end with a fibre gasket washer. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 50 of 171
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.