Dual flush, WC outlet valve. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow.
Indirect heat interface unit with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the heating circuit set @ 2.5 bar. The DHW and heating circuits are both fitted with drain valves incorporating cover caps. Maximum working pressure 16 Bar (Primary), 10 Bar (DHW) & 3 Bar (Heating) Maximum operating temperature 95°C
Tudor range of above and under sink range of electrically heated vented water heaters (cased and insulated) incorporating an angle valve on the inlet for flow control. Maximum working pressure 3.5 bar. Maximum operating temperature 75°C.
Range of in-line water meters with brass bodies and plastic turbines. The inlets incorporate plastic filters, and the outlets incorporate non-return valves (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 65.0°C.
Range of water meters with brass bodies with plastic impellers. LXSZ models incorporate a spherical valve on the inlet. Maximum working pressure 16.0 Bar Maximum operating temperature 50.0°C
Range of water meters with cast iron bodies (blue epoxy coating). Maximum working pressure 16.0 Bar Maximum operating temperature 70.0°C
Range of water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 65.0°C
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of in-line water meters with composite bodies, TPE gasket and NBR ‘O’-ring(s). The products have an integral plastic filter. The inlet of the in-line models includes a non-return valve. Maximum working pressure 16.0 bar. Cold water use only.
Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models 3897590 & 3897690 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Self-closing hand spray with a stainless-steel body. The inlet incorporates a flow regulator and an approved check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5 bar. Max operating temperature 60°C.
Range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold and pumps. Maximum working pressure 10 bar. Cold water use only.
‘AMV-FB’ and ‘AMV-FE’ range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold, vertical multistage pumps, expansion vessel, isolation valves, pressure sensor and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of horizontal multistage close coupled centrifugal pumps incorporating stainless steel cased bodies and impellers. Maximum working pressure: See models. Cold water use only.
Range of shower handsets with plastic bodies (various finishes), handset holder, riser rail and TPE inner lined multilayered shower hose. The handset incorporates a flow restrictor at the inlet. Open Outlet. Maximum operating temperature: 60.0°C.
Range of ABS plastic shower handsets, (various finishes) Maximum operating temperature 85°C.
A range of wall mounted shower handsets (brass bodies) incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection, and plastic flow regulators. The products are also supplied with shower hoses and handset holders. Maximum operating temperature 60.0°C Open outlet use only.
Range of shower outlets (brass bodies – various finishes) incorporating a PEX lined hose as an inner pathway with an aerator type outlet. Open outlet use only. Maximum operating temperature 60.0°C
Range wall mounted shower outlet connectors with brass bodies, chrome finish. The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum operating pressure 10 Bar. Maximum operating temperature 70°C.
Range of overhead shower outlets, wall and ceiling mounted shower arms with (brass bodies - various finishes). The overhead shower inlet incorporates a combined NBR washer and stainless steel strainer. Maximum operating pressure 5 bar. Maximum operating temperature 85°C
Page 480 of 555
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.