Bar type thermostatic blending valve with a chromium plated brass body, a quarter turn ceramic disc headwork with single lever type operating member controlling the flow. Temperature is controlled by a thermostatic mixing valve with a single lever type operating member incorporating with a manual override button. The inlets incorporate stainless steel strainers and approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of floor standing, shower to shower, thermostatic blending valves (brass or stainless steel, various finishes, see models). Incorporating a ceramic cartridge headwork with a single lever operating member. The product incorporates a self-cancelling diverter to overhead shower with a dome operating member. The outlet of the diverter incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also supplied with shower hose and shower handset. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Wall mounted, thermostatic blending valve (brass body) incorporating a single sequential headwork and dome operating member. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies) incorporating a two-way ceramic disc diverter with a dome or cubed type operating member. The temperature is controlled independently via a thermostatic cartridge with dome or cubed type operating members that incorporate a manual override button. The inlets incorporate stainless-steel strainers and approved single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. The products are supplied with shower hose, handset, overhead shower and riser rail assembly. Maximum working pressure:10.0 bar. Maximum operating temperature: 65°C.
Range of thermostatic blending valves, (brass bodies – various finishes), incorporating a thermostatic cartridge. The product is supplied with various trim sets incorporating a cross top, lever or dome type operating member. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating pressure 5 bar. Maximum operating temperature 85°C.
Range of concealed and exposed two-way diverters, (brass bodies – various finishes, trim sets and operating members). The inlets on XX1650YY and XX1721YY models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C (PSA019 YY, PSA020 YY & XX1782YY) Maximum operating temperature 60°C (PSH049, XX1650YY, RZ/1721 & XX1721YY).
Range of pre-set pressure relief valves with a DZR brass body, incorporating an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Compression connection for use with copper tube to BS EN 1057. Maximum working pressure: see models. Maximum operating temperature: 23.0°C
Range of cold-water inlet control groups consisting of an in-line, manually adjustable pressure reducing valve and a pressure relief valve pre-set at either 6.0 or 8.0 bar, housed within DZR brass bodies. The products incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. The pressure reducing valves also have stainless-steel strainers. Maximum inlet pressure 16.0 bar. Cold water use only. CWIC351300 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 6.0 bar CWIC351301 – Outlet pressure range 1.0 to 2.1 bar. Pressure relief valve set at 8.0 bar. CWIC351303 – Outlet pressure range 1.0 to 3.5 bar. Pressure relief valve set at 8.0 bar CWIC351306 – Outlet pressure range 1.5 to 6.0 bar. Pressure relief valve set at 8.0 bar
Inlet control group with a DZR brass body, consisting of a pressure reducing valve and pressure relief valve (6.0 Bar). The inlet incorporates a stainless-steel strainer, and the outlet incorporates an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The product is for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C. Outlet pressure range of the pressure reducing valve is 1.0 to 4.0 bar.
In-line polyphosphate scale inhibitor. The product is supplied with a single check valve cartridge in the inlet connection, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 5.0 bar. Cold water use only.
Range of salt regenerated ion exchange water softeners for domestic use. The gearbox assembly and each elbow assembly incorporate a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Cold water use only.
Range of single-hole, multiple outlet, swivel, (brass bodies - various finishes) a quarter turn ceramic disc controlling the flow to the swivel arm with a dome type operating member and a ceramic cartridge with a single lever controlling the flow to the pull-down spray outlet incorporating a plastic aerator. Maximum working pressure: 10.0bar Maximum operating temperature 60°C
Range of single-hole, multiple outlet, swivel, combination tap assemblies (brass bodies - various finishes) a quarter turn ceramic disc controlling the flow to the swivel arm with a dome type operating member and a ceramic cartridge with a single lever controlling the flow to the pull-out spray outlet incorporating a plastic aerator. The spray outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature for boiling water pathway 98°C, for mixed water pathway 65C and purified water pathway 85°C
Range of wall mounted, two-hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve activated via infra-red sensor. Temperature is controlled independently via a thermostatic cartridge with a dome operating member which incorporates a manual override button. The spout outlets incorporate plastic aerators, and both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The main body incorporates a plastic flow regulator and stainless steel strainer prior to the solenoid. The inlets to the main body of the GS10, CM10 & GH10 model variants incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. These models also have a manual temperature control operated by a single lever on the side of the body. The inlet hoses incorporate a TPE gasket. The models are supplied with or without a pop-up waste. The GS20 & GM20 model variants are single feed. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The inlets to the main body of the M10, GC10, MX10, A10 & L10 model variants incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection, these models also have a manual temperature control operated by a single lever on the side of the body. The inlet hoses incorporate a stainless steel strainer (M10, GC10, MX10, A10 & L10 model variants) or combined TPE washer and stainless strainer (M20, GC20, A20 & L20 model variants). The models are supplied with or without a pop-up waste. The M20, GC20 A20 & L20 model variants are single feed. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of electronic combination tap assemblies, incorporating a solenoid valve controlling the flow that is activated via an infra-red sensor. The Xeris models (012930699 & 012940699) incorporate a check valve cartridge in the inlet hose, however the complete assembly has not been tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of spring loaded, resilient trim check valve cartridges with plastic body. For insertion into fittings with specifically sized bores. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Spring loaded, resilient trim, in-line check valve cartridge with NBR & EPDM ‘O’-rings, plastic guide, stem and body. For insertion into pipes or fittings with specifically dimensioned bores. Maximum working pressure 8.6 Bar. Maximum operating temperature 60°C.
Non-verifiable double check valve assemblies incorporating two spring loaded resilient trim in-line check valve cartridges, DZR brass bodies (brushed chrome) and a drain port located in between the cartridges. The assemblies incorporate spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Non-Verifiable double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a nickel plated DZR brass body. The assembly incorporates an isolation valve. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.
Range of non-verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body with nickel plated or natural finish. Models with compression connections are for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Models 12.10152.015.CP02-8511 & 12.10152.015.CP5R-8511 have a maximum operating temperature of 65°C. All other models have a maximum operating temperature of 85°C
Non-verifiable double check valve assembly with DZR brass body (chrome plated), incorporating two in-line check valve cartridges. Maximum working pressure – 10.0 Bar Maximum operating temperature - 85°C
Non-verifiable, double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a nickel plated, DZR brass body. The assembly incorporates an isolation valve and stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of non-verifiable double check valve assemblies, incorporating two spring loaded resilient trim in-line check valve cartridges housed in DZR brass bodies. The products incorporate a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of single hole bidet combination tap assemblies (brass bodies - various finishes) incorporating a ceramic cartridge headwork and single lever operating member. The swivel nozzle outlet incorporates a plastic aerator and the product is supplied with a lever type pop-up waste – not verified by test. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) over the rim (swivel nozzle) bidet combination tap assembly (chromium plated brass body) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Ceramic cartridge headwork with a plastic body, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 5.0 bar. Maximum operating temperature 90°C.
Ceramic cartridge headworks with a plastic body, incorporating silicone seals and NBR O-rings. The product is intended for insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with brass bodies and EPDM gaskets and O-rings. For insertion into specifically dimensioned bores. Maximum working pressure; 5 Bar Maximum operating temperature 60°C
Range of ceramic cartridge headworks with a plastic body. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Ceramic cartridge headwork with a plastic body. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperatures 85°C (K26PMA-01NP model) and 65°C (K40P-01NPX model).
Range of ceramic cartridge headworks with plastic bodies for insertion into specifically dimensioned tap assemblies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Ceramic cartridge headwork with a plastic body, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 5.0 bar. Maximum operating temperature 90°C.
Ceramic cartridge headwork with a plastic body and EPDM seals, for insertion into specifically dimensioned tap assemblies. Maximum working pressure 16.0 Bar. Maximum operating temperature 80°C
Range of ceramic cartridge headworks with plastic bodies. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with a plastic body. For insertion into specifically dimensioned bodies. Maximum working pressure 10.0 Bar. Maximum operating temperature 85 °C.
Ceramic cartridge headwork with a plastic body. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Range of ceramic cartridge headworks with plastic bodies, EPDM gaskets and NBR O-rings. The products are for insertion into specifically dimensioned bores. Maximum working pressure 5.0 Bar Maximum operating temperature 85.0°C
Range of ceramic cartridge headworks with plastic bodies. For insertion into specifically dimensioned bodies. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies. For insertion into specifically dimensioned bodies. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), models (63792 & 63794) incorporate ceramic cartridge headworks, model (63793 incorporates quarter turn ceramic disc headworks both with single lever operating members. The spout outlet is a pull-out spray type. The inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), models EMB10CP, EMB10BN, EMB10BB, EMB10MB, EMB10WH, CREPOCP & CREPOBN incorporate ceramic cartridge headworks, model (ARI10CP, ARI10BN, ARI10BB, ARI10MB & ARI10WH incorporates quarter turn ceramic disc headworks both with single lever operating members. The spout outlet is a pull-out spray type. The inlets incorporate approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet (swivel) combination tap assemblies (chrome plated brass bodies). Incorporating ceramic cartridge headworks and single lever operating members. The flexible spout outlet incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single-hole, single outlet (swivel) combination tap assemblies (brass body – various finishes) incorporating a ceramic cartridge (MARTA CH) or quarter turn ceramic disc (ALTUS CH) headwork with a single lever operating member. The products have a pull-out spray outlet which incorporates a plastic aerator and trigger mechanism that stops the flow (model (ALTUS CH) or changes the water pattern from straight flow to spray (MARTA CH). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-down spray with a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass body – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a pull-out spray type. Maximum working pressure 10.0 Bar. Maximum operating temperature 65.0°C.
Range of single hole, single outlet (swivel) pull down spray combination tap assemblies (brass bodies – various finishes), model (62861-01X) incorporates quarter turn ceramic disc headworks, models (62931-00X & 62932-00X) incorporate ceramic cartridge headworks, all with single lever operating members. The outlet incorporates a plastic aerator. Model (62861-01X) incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Single hole, single outlet fixed combination tap assemblies (chrome plated brass finish), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Page 47 of 56
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.